Daikin RKS71FVLT [158/244] Removal of electrical box pcb swing motor

Daikin RKS50FVMA [158/244] Removal of electrical box pcb swing motor
Si04-703A Indoor Unit
Removal Procedure 147
1.4 Removal of Electrical Box / PCB / Swing Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the front grille.
Parts layout
2. Remove the drip proof
plate.
1
Loosen the screw.
2
Cut the clamp.
3. Disconnect the indoor
heat exchanger thermistor
and the earth.
Be careful not to lose the clip
for the thermistor.
(R6707)
Indoor heat exchanger thermistor
Earth
(R6708)

Содержание