Daikin RKS71FVLT [221/244] Removal of compressor

Daikin RKS50FVM [221/244] Removal of compressor
Outdoor Unit Si04-703A
210 Removal Procedure
2.2.7 Removal of Compressor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1
Remove the terminal
cover.
2
Pull out the 3 leads
using long-nose pliers.
U:red, V:yellow, W:blue
3
Remove the OL.
4
Remove the 3 screws.
(R7020)
(R6467)
W(blue)
U(red)
V(yellow)
OL
(R7021)