Daikin CDKD35CVM [12/16] Pcrsg0719a_21_22

Daikin CDKD25CVM [12/16] Pcrsg0719a_21_22
21
22
OptionsSpecifications
Specifications
Outdoor unit
Indoor unit
Duct-connected type
Floor/ceiling-suspended dual type
1 phase, 220-240 V/220-230 V, 50/60 Hz
Hermetically sealed swing type
25 (for one room)
Chargeless
15 (between indoor and outdoor units)
2MKD58DVM
35 (total)
dB (A)
mm
kg
˚CDB
m
g/m
m
4MKD100DVM
770 x 900 x 320
56
70 (total)
4MKD75DVM
48/45*
46/43*
55
3MKD75DVM
Ivory white
10 to 46
735 x 936 x 300
Note: * The first value, to the left of the slash, is the rated condition. The value to the right of the slash is the second level when outdoor unit quiet operation.
60 (total)
58
FTKD50FVM
16.8 (593)
44/35/32
FTKD35DVM
9.0 (318)
39/29/26
FTKD60FVM
17.5 (618)
45/36/33
FTKD71FVM
18.3 (646)
46/37/34
ø9.5
FTKD25DVM
8.9 (314)
37/28/25
ø9.5
Liquid (flare)
Gas (flare)
Drain
m
3
/min (cfm)
dB (A)
mm
kg
mm
ø6.4
ø12.7
283 x 800 x 195
9
290 x 1,050 x 238
ø15.9
Wall-mounted type
Measurement conditions
1. Data is based on the following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
2. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
FLK25AVMA
7.6 (268)
37/31/28
ø9.5
FLK35AVMA
8.7 (307)
38/32/29
FLK50AVMA
11.4 (402)
47/39/36
FLK60AVMA
12.0 (424)
48/41/38
ø15.9
Liquid (flare)
Gas (flare)
Drain
m
3
/min (cfm)
dB (A)
mm
kg
mm
ø12.7
16 17
3MKD58DVM
45 (total)
Model name
Power supply
Casing colour
Compressor type
Sound levels
Dimensions (H x W x D)
Machine weight
Operation range
Max. piping length
Necessity of additional charge
Max. installation height difference
1 phase, 220-240 V/220-230 V, 50/60 Hz
White
Model name
Power supply
Front panel colour
Airflow rates (H)
Sound levels (H/L/SL)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping
connections
Heat insulation
1 phase, 220-240 V/220-230 V, 50/60 Hz
Almond white
5 steps, quiet and automatic
Microcomputer control
490 x 1,050 x 200
ø6.4
ø18.0
Both liquid and gas pipes
Model name
Power supply
Front grille colour
Airflow rates (H)
Sound levels (H/L/SL)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping
connections
Heat insulation
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 35 Pa for CDKD-EA and 40 Pa for CDKD-C. Sound
level values for bottom-suction operation can be obtained by adding 6 dB (A) for CDKD-EA and 5 dB (A) for CDKD-C.
12
ø18.0
Both liquid and gas pipes
5 steps, quiet and automatic
Microcomputer control
Model name
Power supply
Airflow rates (H)
Sound levels (H/L/SL)*
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
External static pressure
Liquid (flare)
Gas (flare)
Drain
dB (A)
mm
kg
mm
Pa
1 phase, 220-240 V/220-230 V, 50/60 Hz
5 steps, quiet and automatic
Microcomputer control
ø6.4
VP 20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
CDKD50CVM
12.0 (424)
37/33/31
27
CDKD60CVM
16.0 (565)
38/34/32
200 x 1,100 x 620
30
ø15.9
35/31/29
8.7 (307)
200 x 700 x 620
21
35
CDKD35CVM
10.0 (353)
200 x 900 x 620
CDKD25CVM
9.5 (335)
ø9.5
CDKD35EAVMCDKD25EAVM
m
3
/min (cfm)
ø9.5 ø12.7
ø12.7
40
25
Options
Outdoor unit
No.
1
2
Item
Air direction adjustment grille
Drain plug
4MKD100D
KKP945A4*
2
4MKD75D3MKD75D3MKD58D
2MKD58D
KKP937A4*
1
KPW945A4
Air direction adjustment grille
KPW945A4
Drain plug
KKP937A4
Notes: *1. One set includes 5 pieces for 5 units.
*2. One set includes 1 piece for 1 unit.
Control system
Indoor unit
No.
1
2
3
4
5
6
7
8
9
10
11
5-room centralised controller*
1
Wiring adaptor for time clock/remote controller
*
2
(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter*
3
Photocatalytic deodorising filter with frame*
4
Photocatalytic deodorising filter without frame*
4
Air-purifying filter with frame*
5
Air-purifying filter without frame*
5
Air-purifying filter with photocatalytic deodorising function without frame*
6
Remote controller loss prevention chain
Suction grille
Insulation kit for high humidity
FTKD50/60/71F
KAF952A42
CDKD25/35EA CDKD60C
KDT25N63
CDKD25/35/50C
KDT25N50
KRC72
KRP413AB1S
KAF952B42
FTKD25/35D
Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*2. Time clock and other devices should be obtained locally.
*3. Filter is a standard accessory. It should be replaced approximately 3 years.
*4. The photocatalytic deodorising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months. This accessory is only
required if the original filter is damaged or lost, etc.
*5. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.
*6. The air-purifying filter with photocatalytic deodorising function is a standard accessory. It should be replaced approximately 3 years.
KAZ970A42
KAF970A42
KAZ917B41
KAZ917B42
KAF925B41
KAF925B42
No.
1
2
3
4
Item
Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor for DIII-NET use
DCS302CA61
DCS301BA61
DST301BA61
KRP928BB2S
Note: * Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
Wall-mounted type
Wall-mounted type
Duct-connected type
Floor/ceiling-
suspended dual type
Duct-connected type Floor/ceiling-suspended dual type
Item
——
——
KDGF19A45
5-room centralised
controller
KRC72
Remote controller loss
prevention chain
KKF917A4
Central remote controller
DCS302CA61
Unified on/off controller
DCS301BA61
Schedule timer
DST301BA61
KKF917A4
KDT25N32
Air-purifying filter without frame
KAF970A42
Air-purifying filter with
photocatalytic deodorising function
KAF952A42
Titanium apatite photocatalytic
air-purifying filter
KAF952B42

Содержание