Daikin CDKD35CVM [9/16] Pcrsg0719a_15_16

Daikin CDKD25CVM [9/16] Pcrsg0719a_15_16
15
16
When you are in the room
When you go out
Intelligent Eye with its infrared sensor automatically
controls air conditioner operation according to human
movement in a room. When there is no movement, it
adjusts the temperature by 2˚C for energy savings.
Intelligent Eye is available for all wall-mounted models.
Start Home Leave Operation simply by
pushing its button on the remote controller.
When you are out of your home, your air conditioner prevents large rises
in the indoor temperature by continuing to operate using Home Leave
Operation settings.
When you return, you will be greeted by an
air-conditioned room. Just push the HOME
LEAVE button again to return to your
previous settings.
23˚C for the room temperature setting, and 28˚C for the home leave setting.
Wide-Angle Louvres
The louvres can be adjusted
by hand for the FTKD25/35D
and FLK25/35/50/60A.
The louvres can be adjusted
with the wireless remote
controller for the
FTKD50/60/71F.
Home Leave Operation prevents large rises in the indoor
temperature by continuing operation* while you are
sleeping or out of your home. This means that an air-
conditioned welcome awaits when you wake or return. It
also means that the indoor temperature can quickly return
to your favourite comfort setting.
* Home Leave Operation can be selected for any temperature from 18 to
32˚C.
Entirely covers
a spacious room
From a corner
to the centre
Econo Mode
Econo Mode is a function that reduces the maximum
running current and the maximum power consumption of
the outdoor unit to the rated values. This mode is useful for
preventing circuit breakers from being overloaded by the
use of multiple air conditioners and other electrical devices.
The function is easily activated from the remote controller
by pushing the ECONO button. Econo Mode is available
for the FTKD25/35D.
Refer to page 14 to check the functions offered by individual models.
Functions Functions
Energy savings plus quick return to favourite comfort setting levels
Uniform cooling of the whole living room
Room temperature is raised by 0.5˚C after 60 minutes.
From start up until set
temperature is reached
Maximum
Rated
• This diagram is a representation for illustrative purposes only.
• Maximum capacity decreases during Econo Mode, requiring
more time to reach the set temperature.
Maximum during
normal operation
Running current and
power consumption
Time
Normal
operation
Econo
Mode
Maximum during
Econo Mode
One push!!
Push again!!
Indoor Unit On/Off Switch
Unit: minutes60
Set temp. before
Off timer begins
to operate
+0.5˚C
Off timer turns on Off timer stops air conditioner
Intelligent Eye Home Leave Operation Vertical Auto-Swing (up and down)
Horizontal Auto-Swing (left and right)
Vertical Auto-Swing automatically moves the flaps up and
down and Horizontal Auto-Swing automatically moves the
louvres to the left and right. 3-D Airflow combines Vertical
and Horizontal Auto-Swing to circulate air to every part of
a room for uniform cooling of even large spaces.
3-D Airflow
Pressing the Off timer button automatically selects the
Night Set Mode. This function prevents excessive cooling
for pleasant sleep conditions.
Night Set Mode
The unit can be conveniently started
manually in the event the wireless
remote controller is misplaced or the
wireless remote controller batteries
are not charged.
Indoor Unit On/Off Switch
Inverter Powerful Operation boosts cooling performance for
a 20-minute period. This is convenient both when you first
turn on your air conditioner and when you want to quickly
change the temperature during operation.
Inverter Powerful Operation
Power-Airflow Dual Flaps
Power-Airflow Dual Flaps and Wide-Angle Louvres work in
tandem to precisely control both vertical and horizontal
airflow for even distribution of air.
Wide-Angle Louvres
23˚C
28˚C
23˚C
The flaps flatten out during operation so that cool air slides off to reach the
farthest corners of the room.
Power-Airflow Dual Flaps
Time

Содержание