Daikin FHQ71BUV1B [269/340] Removal of horizontal blade

Daikin FHQ100BUV1B [269/340] Removal of horizontal blade
FHQ35/50/60BUV1B Si21-205A
258 Removal Procedure
2.3 Removal of Horizontal Blade
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1
Gently bend the support
plate located at the
center of the horizontal
blade, and detach the
center shaft.
(Two shafts provided on
Types 140 and 160.)
2
Then gently bend the
center of the horizontal
blade, and take both
the end shafts out of
their bearings.
When removing the
horizontal blade from the
bearings at both ends, be
careful not to get the blow
port thermal insulation
scratched.
Reassembling precautions
1
The shaft at the right
end of the horizontal
blade is cut in D shape.
Fit this D-shaped end to
the D-profiled bearing.
Reattach the horizontal
blade at the right side
first.