Daikin FH45BZV1 [12/26] Dimensional drawings
![Daikin FH35BZV1 [12/26] Dimensional drawings](/views2/1779625/page12/bgc.png)
FH45BZV1
View from the front
780 From the floor side 2500 or more
(Required space)
Note:
1. Location of unit’s name plate: bottom of fan housing inside the
suction grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
3. The remote control code is the standard (about 3m outside the
machine) attached.
(0.5 mm
2
x 2 Wicks x O.D. J5.4)
(It is not attached in VRV.)
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas pipe connection J15.9 flare
5 Liquid pipe connection J6.4 flare
6 Drain pipe connection VP20
7 Earth terminal (inside the electric components box) M4
8 Suspension bracket
9 Backward piping and wiring connection opening lid
10 Upward piping and wiring connection opening lid
11 Right side pipe connection - slit hole
12 Left back drain pipe connection - slit hole
13 Right side drain pipe connection - slit hole
14 Right side drain piping connection hole- slit hole
15 Hole of wall for taking out in piping back J100
16 Upward drain pipe connection J60
17 Upward gas pipe connection J36
18 Upward liquid pipe connection J26
Position: hole of wall for taking out in piping back
For height installation
Floor side
300or more
Brand name plate
(For left piping)
30 or more
30 or more
(Service space)
(View from the front)
(Hanging position)
Hanging bolt
Position slit hole for taking out in piping back
3D028600
Drain pipe connection
VP20
Obstacle
(Service space)
(View from the front)
(Hanging position)
(Required space)
(Required space)
(Note 2)
FH60BZV1
View from the front
780 From the floor side 2500 or more
(Required space)
Note:
1. Location of unit’s name plate: bottom of fan housing inside the
suction grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
3. The remote control code is the standard (about 3m outside the
machine) attached.
(0.5 mm
2
x 2 Wicks x O.D. J5.4)
(It is not attached in VRV.)
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas pipe connection J15.9 flare
5 Liquid pipe connection J6.4 flare
6 Drain pipe connection VP20
7 Earth terminal (inside the electric components box) M4
8 Suspension bracket
9 Backward piping and wiring connection opening lid
10 Upward piping and wiring connection opening lid
11 Right side pipe connection - slit hole
12 Left back drain pipe connection - slit hole
13 Right side drain pipe connection - slit hole
14 Right side drain piping connection hole- slit hole
15 Hole of wall for taking out in piping back J100
16 Upward drain pipe connection J60
17 Upward gas pipe connection J36
18 Upward liquid pipe connection J26
Position: hole of wall for taking out in piping
back
For height installation
Floor side
300or more
Brand name plate
(For left piping)
30 or more
30 or more
(Service space)
(View from the front)
(Hanging position)
Hanging bolt
Position slit hole for taking out in piping back
3D027537
Drain pipe connection
VP20
Obstacle
(Service space)
(View from the front)
(Hanging position)
(Required space)
(Required space)
(Note 2)
• Ceiling Suspended Unit • R-407C • FH(Y)-GZ/BZ/FHYP-B
3
Dimensional drawings
10
3
10
• Split - Sky Air • Indoor Units
Содержание
- Daikin products are distributed by 2
- Internet http www daikin be 2
- Prepared in belgium by goekint graphics 05 2001 2
- Specifications are subject to change without prior notice 2
- Split sky air 2
- Zandvoordestraat 300 b 8400 oostende 2
- Table of contents 3
- Table of contents fh y gz bz fhyp b 3
- Features 4
- Specifications 5
- Specifications 5
- Specifications 6
- Specifications 7
- Specifications 8
- Specifications 9
- Specifications 10
- Air discharge grille 2 air suction grille 3 air filter 4 gas pipe connection j 12 flare 5 liquid pipe connection j 6 flare 6 drain pipe connection vp20 7 earth terminal inside the electric components box m4 8 suspension bracket 9 backward piping and wiring connection opening lid 10 upward piping and wiring connection opening lid 11 right side pipe connection slit hole 12 left back drain pipe connection slit hole 13 right side drain pipe connection slit hole 14 right side drain piping connection hole slit hole 15 hole of wall for taking out in piping back j 100 16 upward drain pipe connection j 60 17 upward gas pipe connection j 36 18 upward liquid pipe connection j 26 11
- Dimensional drawings 11
- Slit hole position for rear piping connection 11
- View from the front 11
- Wall hole position for rear piping connection 11
- Dimensional drawings 12
- Dimensional drawings 13
- Dimensional drawings 14
- Check valve 15
- D024085a 15
- Field piping 15
- Flange connection 15
- Flare connection 15
- Gas pipe connection port filter 15
- Heat exchanger 15
- Indoor heat exchanger 15
- Indoor unit 15
- Liquid pipe connection port 15
- Pinched pipe 15
- Piping diagrams 15
- Screw connection 15
- Spinned pipe 15
- To outdoor unit 15
- Tw20435 1e 15
- Details of wired remote control optional accessory 16
- Indoor 16
- Note 4 note 5 16
- Outdoor 16
- Switch box 16
- Terminals for operation indicator 16
- Wiring diagrams 16
- Indoor unit master indoor unit slave 17
- Wiring diagrams 17
- Sound level 18
- Sound level data 18
- Octave band center frequency hz 19
- Octave band center frequency hz octave band center frequency hz 19
- Octave band sound pressure level 19
- Octave band sound pressure level octave band sound pressure level 19
- Sound level 19
- Sound pressure spectrum 19
- Sound level 20
- Accessories 21
- Drain hose 21
- For liquid pipe 21
- Installation manual 21
- Insulation for fitting sealing pad 21
- Operation manual 21
- Standard accessories 21
- Washer for hanging bracket 21
- Washer fixing plate 21
- Accessories 22
- Optional accessories 22
- Control systems 23
- Wired remote control 23
- Control systems 24
- Name and function of each switch and display on the remote control fig 24
- Note for the sake of explanation all indications are shown on the display in figure 3 4 contrary to actual running situations 24
- Control systems 25
- Operation procedure wired remote control 25
- Installation 26
- Safety device settings 26
Похожие устройства
- Daikin FH45BZV1 Сервис мануал
- Daikin FH60BZV1 Инструкция по монтажу
- Daikin FH60BZV1 Инструкция по эксплуатации
- Daikin FH60BZV1 Технические данные
- Daikin FH60BZV1 Сервис мануал
- Daikin FHYP35BJV1 Инструкция по эксплуатации
- Daikin FHYP35BJV1 Инструкция по монтажу
- Daikin FHYP45BJV1 Инструкция по монтажу
- Daikin FHYP45BJV1 Инструкция по эксплуатации
- Daikin FHYP60BJV1 Инструкция по монтажу
- Daikin FHYP60BJV1 Инструкция по эксплуатации
- Daikin FHYP71BJV1 Инструкция по эксплуатации
- Daikin FHYP71BJV1 Инструкция по монтажу
- Daikin FHYP100BJV1 Инструкция по монтажу
- Daikin FHYP100BJV1 Инструкция по эксплуатации
- Daikin FHYP125BJV1 Инструкция по монтажу
- Daikin FHYP125BJV1 Инструкция по эксплуатации
- Евроавтоматика OM-1 Инструкция по эксплуатации
- Евроавтоматика OM-1 Каталог
- Евроавтоматика OM-3 Инструкция по эксплуатации