Periodic checks
Cleaning the cartridge filter
- Release the levers (8 Fig. 3) and remove
the cover (9 Fig. 4) complete with motor
unit.
- Loosen the knob (55 Fig. 28) and remove
the filter (56 Fig. 28).
- Clean the filter (56 Fig. 29) with a jet of air
from the inside outwards; the filter can be
washed (56 Fig. 29) in warm water. Re-
mount it only when it is completely dry,
replace it if it is too dirty.
- Re-mount everything, proceeding in the
opposite order to disassembly.
Checking the air outlet filter
- Loosen the screws (41 Fig. 30) and re-
move the cover (42 Fig. 30).
- Remove the foam tank (43 Fig. 31) and
the texture sponges (44 Fig. 32) if any.
- Clean the sponges with a blast of air (Fig.
33).
The filter sponges can be washed in
warm water and must only be replaced
once they are completely dry; if too dirty,
replace them with new ones.
- Reassemble all the parts by following the
dismantling process steps in the reverse
order.
Checking the floater
- Remove the top as shown above.
- Check If the floater (45 Fig. 34) is In
good condition and if it moves freely in its
space.
- Re-mount everything, proceeding in re-
verse order.
PROBLEM CAUSE SOLUTION
The vacuum cleaner does
not work.
Switch not pressed.
Plug not inserted.
No current.
Press the switch.
Insert the plug into the sock-
et.
Check the power supply line.
Suction is not satisfactory. Paper bag full.
Filter elements clogged.
Accessories or tubes
clogged.
Suction nozzle squeegee
worn or damaged.
Replace the dust bag.
Clean the filter elements.
Check and clean the flexible
hose and the suction nozzle.
Check and replace the
squeegee.