Daikin FDKS60C7VMB [10/28] If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off
![Daikin FDKS60C7VMB [10/28] If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off](/views2/1780985/page10/bga.png)
9
■ To set the clock
1. Press “CLOCK button”.
is displayed.
blinks.
2. Press “TIMER setting button”
to set the clock to the present
time.
Holding down “ ” or “ ” button rapidly
increases or decreases the time display.
3. Press “CLOCK button”.
blinks.
■ Turn the breaker ON
• Turning ON the breaker opens the flap,
then closes it again. (This is a normal
procedure.)
NOTE
■
Tips for saving energy
•
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
•
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
•
Clogged air filters cause inefficient operation and waste energy. Clean them
once in about every two weeks.
■
Please note
•
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
•
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
•
Use the air conditioner in the following conditions.
• Operation outside this humidity or temperature range may cause a safety device to disable the system.
1, 3
2
Recommended temperature setting
For cooling:26
°
C – 28
°
C
For heating:20
°
C – 24
°
C
Mode Operating conditions If operation is continued out of this range
COOL
Outdoor temperature:〈2MK(X)S40〉 10 to 46°C
〈2MXS52〉 –10 to 46°C
〈
3/4/5MK(X)S
〉
–10 to 46°C
〈RK(X)S〉 –10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of the
outdoor unit only.)
• Condensation may occur on the indoor unit and drip.
HEAT
Outdoor temperature:〈2MXS40〉 –10 to 15.5°C
〈2MXS52〉 –15 to 15.5°C
〈
3/4/5MXS
〉
–15 to 15.5°C
〈
RXS20/25/35
〉
–15 to 20°C
〈RXS50/60〉 –15 to 18°C
Indoor temperature: 10 to 30°C
• A safety device may work to stop the operation.
DRY
Outdoor temperature:〈2MK(X)S40〉 10 to 46°C
〈2MXS52〉 –10 to 46°C
〈
3/4/5MK(X)S
〉
–10 to 46°C
〈RK(X)S〉 –10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
Содержание
- Daikin room air conditioner 1
- Operation manual 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Caution 3
- Safety precautions 3
- Warning 3
- Consider nuisance to your neighbours from noises 4
- Electrical work 4
- Installation site 4
- System relocation 4
- Indoor unit 5
- Names of parts 5
- Outdoor unit 6
- Remote controller 7
- Attention 8
- Preparation before operation 8
- To set the batteries 8
- Attention 9
- Choose a place from where the signals reach the unit 9
- Fix the holder to a wall a pillar etc with the screws supplied with the holder 9
- Place the remote controller in the remote controller holder 9
- Preparation before operation 9
- To fix the remote controller holder on the wall 9
- To operate the remote controller 9
- If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off 10
- Press clock button 10
- Press timer setting button to set the clock to the present time 10
- To set the clock 10
- Turn the breaker on 10
- Auto dry cool heat fan operation 11
- Press mode selector button and select a operation mode 11
- Press on off button 11
- Press on off button again 11
- Press temperature adjustment button 11
- To change the temperature setting 11
- To start operation 11
- To stop operation 11
- Press fan setting button 12
- To change the air flow rate setting 12
- Powerful operation 13
- To cancel powerful operation 13
- To start powerful operation 13
- Outdoor unit quiet operation 14
- To cancel outdoor unit quiet operation 14
- To start outdoor unit quiet operation 14
- Before using home leave operation 15
- Home leave operation 15
- To cancel home leave operation 15
- To start home leave operation 15
- Disengaging home leave operation will return the temperature to that set for normal operation even the coldest winters will pose no problem 16
- Use as a favorite mode 16
- Use as an energy saving mode 16
- Useful in these cases 16
- What s the home leave operation 16
- Timer operation 17
- To cancel the off timer operation 17
- To use off timer operation 17
- Attention 18
- Press cancel button 18
- Press on timer button 18
- Press on timer button again 18
- Press timer setting button until the time setting reaches the point you like 18
- To cancel on timer operation 18
- To combine on timer and off timer 18
- To use on timer operation 18
- Night quiet mode available only for cooling operation 19
- Note for multi system 19
- Outdoor unit quiet operatio 19
- Selecting the operation mode 19
- Example room a is the priority room in the examples 20
- Operation mode priority 20
- Priority room setting 20
- Priority when powerful operation is used 20
- Priority when using outdoor unit quiet operation 20
- The priority room setting requires initial programming during installation please consult your retailer or dealer for assistance 20
- Attach the filter to the main unit while pushing down on the bends 2 bends for 25 35 type 3 bends for 50 60 type 21
- Before cleaning be sure to stop the operation and turn the breaker off 21
- Care and cleaning 21
- Caution 21
- Cleaning the air filter 21
- Filter 21
- In case of back side in case of bottom side 21
- Main unit 21
- Only a qualified service person is allowed to perform maintenance 21
- Removing the air filter 21
- Replacing the air filter 21
- Before a long idle period 22
- Caution 22
- Clean the air filters and set them again 22
- Cleaning the drain pan 22
- Operate the fan only for several hours on a fine day to dry out the inside 22
- Take out batteries from the remote controller 22
- Turn off the breaker for the room air conditioner 22
- Case explanation 23
- These cases are not troubles 23
- Trouble shooting 23
- Case check 24
- Check again 24
- Call the service shop immediately 25
- Disposal requirements 25
- Important information regarding the refrigerant used 25
- The power cord is abnormally hot or damaged an abnormal sound is heard during operation the safety breaker a fuse or the earth leakage breaker cuts off the operation frequently a switch or a button often fails to work properly there is a burning smell water leaks from the indoor unit 25
- Turn the breaker off and call the service shop 25
- Warning 25
- We recommend periodical maintenance 25
- A short beep and two consecutive beeps indicate non corresponding codes 26
- Fault diagnosis 26
- In the arc433 series the temperature display sections on the main unit indicate corresponding codes 26
- The code indication changes in the sequence shown below and notifies with along beep 26
- To cancel the code display hold the timer cancel button down for 5 seconds the code display also cancel itself if the button is not pressed for 1 minute 26
- Turn the power off and then on again if the led display recurs the outdoor unit pcb is faulty 27
Похожие устройства
- Daikin FDKS60C7VMB Сервис мануал
- Denzel CDL-12-02 (26101) Инструкция по эксплуатации
- Denzel BLDL-IB-18-02 (26121) Инструкция по эксплуатации
- Denzel CDL-IB-12-02 (26111) Инструкция по эксплуатации
- Denzel CDL-IB-18-02 (26113) Инструкция по эксплуатации
- Denzel CDL-IB-14-02 (26112) Инструкция по эксплуатации
- Denzel BLG-IB-18-02 (27002) Инструкция по эксплуатации
- Denzel MTL-IB-18-02 (28401) Инструкция по эксплуатации
- Denzel CSL-3.6-01 (26001) Инструкция по эксплуатации
- Denzel CSL-3.6-02 (26002) Инструкция по эксплуатации
- Denzel EM-1-1600 (27904) Инструкция по эксплуатации
- Denzel EM-1-1220 (27903) Инструкция по эксплуатации
- Denzel EM-2-1600 (27911) Инструкция по эксплуатации
- Denzel ID-750 (26307) Инструкция по эксплуатации
- Denzel ID-1050-2 (26312) Инструкция по эксплуатации
- Denzel ID-850 (26309) Инструкция по эксплуатации
- Denzel ID-650 (26304) Инструкция по эксплуатации
- Denzel ID-550 (26302) Инструкция по эксплуатации
- Denzel JS-65 (27101) Инструкция по эксплуатации
- Denzel JS-110 (27107) Инструкция по эксплуатации