This instruction manual explains control commands from external equipment such as personal
computers to control “MC-980”. Please refer to “Output data format” about output data of
measurement result.
1
Specifications
Communication Method: Asynchronous Transmission
Signal speed: 4800, 9600, 19200 baud (selectable)
Data bit length: 8 bits
Parity: None
Stop bit: 1 bit
Flow control: None, Hardware, XON/XOFF (selectable)
Terminator: CR+LF
2
Preparation for connection
1. Connect equipment to PC
Connect equipment to PC by USB cable.
2. Communication setting on PC
Setup PC communication Signal speed, Data bit length, Parity, Stop bit and Flow control.
It is necessary to install device driver.
3
PC-Mode
3
.1
Equipment statuses on PC-Mode
MC-980 is operated on 8 statuses.
Status x system start-up
Status 0 non-PC-Mode (Normal Mode)
PC-Mode Status 1 PC-Mode / preparing setup
PC-Mode Status 2 PC-Mode / completed setup
PC-Mode Status 3 PC-Mode / preparing setup (for extension mode)
PC-Mode Status 4 PC-Mode / completed setup (for extension mode)
PC-Mode Status 5 PC-Mode / setting zero point
(continues until completing set to zero point)
PC-Mode Status 6 PC-Mode / measuring body weight and impedance
PC-Mode Status 7 PC-Mode / displaying measurement result
(continues until stepping off a platform)
3
.2
Attention
Some commands are not accepted according to status.
After it turns on power, the equipment is in the state of “Status 0” (non-PC-Mode).
Send “M1” (status change command to PC-Mode) from a host, and then the equipment changes to
“Status 1” (PC-Mode)
Содержание
- Mc 980ma instructions for pc mode 1
- Table of contents 2
- 1 specifications 3
- 2 preparation for connection 3
- 3 attention 3
- 3 equipment statuses on pc mode 3
- 3 pc mode 3
- Page 4 13 4
- 3 state transition diagram 4
- 4 communication command 5
- 4 list of commands 5
- E0 internal trouble in equipment e1 overload of scale e2 impedance measurement error e3 zero point setting error of scale e4 measurement command received without setting personal information e5 zero point of the scales are not set e6 the parameter of the set data is imperfect e7 fat measurement error e8 setting item memory error e9 negative overload of scale 6
- 4 details of command 6
- No reaction 7
- Result numbe 8
- Target fat 8
- Result numbe 10
- Target body fat 10
- 5 output data format 12
- Header 13
- Page 13 13 15
- 6 revision history 15
Похожие устройства
- Siemens LC958BA90 Инструкция по эксплуатации
- Fagor 5CF-56MSPB Инструкция по эксплуатации
- Tanita BF 522 W Инструкция по эксплуатации
- Gorenje DK9P2X Инструкция по эксплуатации
- Tanita BF 350 Инструкция по эксплуатации
- Fagor 5CF-56VDPX Инструкция по эксплуатации
- Siemens LI28031 Инструкция по эксплуатации
- Tanita BC 420 MA Инструкция по эксплуатации
- Fagor 5CH-56GSF B Инструкция по эксплуатации
- Siemens LI 46631 Инструкция по эксплуатации
- Fagor 6CF-56EB Инструкция по эксплуатации
- Tanita BC 418 MA Инструкция по эксплуатации
- Sony VPC-F23Z1R/BI Black Инструкция по эксплуатации
- Tanita CJ-688 Инструкция по эксплуатации
- Fagor 6CF-56GSB Инструкция по эксплуатации
- Tanita HC-207 Инструкция по эксплуатации
- Asus Padfone + Padfone Station Инструкция по эксплуатации
- Fagor 6CF-56VDMB Инструкция по эксплуатации
- Microlife ST 71 Инструкция по эксплуатации
- Rapoo T6 Touch Black Инструкция по эксплуатации
Скачать
Случайные обсуждения