10. Input “preset tare”
Input preset tare information.
XX.X of command format is 4 bytes fixed length.
(2 integer bytes, 1 decimal point byte and 1 fraction part byte)
Please input "0" at the blank when integer part is less than 2 digits.
It can be input in the range of 0.0-10.0
Default value is 0.0
(1-2 integer bytes, 1 decimal point byte and 1 fraction part byte)
Command format D0XX.X 00.0-10.0
ACK format D0
Reaction equipment is set preset tare
Transmission example D001.0 preset tare 1.0kg
ACK D0
Parameter error D0!
11. Input “gender”
Input gender information.
X of command format is 1 byte fixed length. (Female=2, Male=1)
Command format D1X
ACK format D1
Reaction equipment is set gender
Transmission example D11 Male
ACK D1
Parameter error D1!
12. Input “body type”
Input body type information.
X of command format is 1 byte fixed length. (Standard=0, Athletic=2)
Command format D2X
ACK format D2
Reaction equipment is set body type
Transmission example D20 Standard
ACK D2
Parameter error D2!
13. Input “height”
Input height information.
XXX.X of command format is 5 bytes fixed length.
(3 integer bytes, 1 decimal point byte and 1 fraction part byte)
Please input "0" at the blank when integer part is less than 3 digits.
It can be input in the range of 90-249
Command format D3XXX
ACK format D3
Reaction equipment is set height
Transmission example D3175.4 height 175.4cm
ACK D3
Parameter error D3!
Содержание
- Mc 980ma instructions for pc mode 1
- Table of contents 2
- 1 specifications 3
- 2 preparation for connection 3
- 3 attention 3
- 3 equipment statuses on pc mode 3
- 3 pc mode 3
- Page 4 13 4
- 3 state transition diagram 4
- 4 communication command 5
- 4 list of commands 5
- E0 internal trouble in equipment e1 overload of scale e2 impedance measurement error e3 zero point setting error of scale e4 measurement command received without setting personal information e5 zero point of the scales are not set e6 the parameter of the set data is imperfect e7 fat measurement error e8 setting item memory error e9 negative overload of scale 6
- 4 details of command 6
- No reaction 7
- Result numbe 8
- Target fat 8
- Result numbe 10
- Target body fat 10
- 5 output data format 12
- Header 13
- Page 13 13 15
- 6 revision history 15
Похожие устройства
- Siemens LC958BA90 Инструкция по эксплуатации
- Fagor 5CF-56MSPB Инструкция по эксплуатации
- Tanita BF 522 W Инструкция по эксплуатации
- Gorenje DK9P2X Инструкция по эксплуатации
- Tanita BF 350 Инструкция по эксплуатации
- Fagor 5CF-56VDPX Инструкция по эксплуатации
- Siemens LI28031 Инструкция по эксплуатации
- Tanita BC 420 MA Инструкция по эксплуатации
- Fagor 5CH-56GSF B Инструкция по эксплуатации
- Siemens LI 46631 Инструкция по эксплуатации
- Fagor 6CF-56EB Инструкция по эксплуатации
- Tanita BC 418 MA Инструкция по эксплуатации
- Sony VPC-F23Z1R/BI Black Инструкция по эксплуатации
- Tanita CJ-688 Инструкция по эксплуатации
- Fagor 6CF-56GSB Инструкция по эксплуатации
- Tanita HC-207 Инструкция по эксплуатации
- Asus Padfone + Padfone Station Инструкция по эксплуатации
- Fagor 6CF-56VDMB Инструкция по эксплуатации
- Microlife ST 71 Инструкция по эксплуатации
- Rapoo T6 Touch Black Инструкция по эксплуатации
Скачать
Случайные обсуждения