Daikin FTXTA30B2V1BW [4/12] About the unit
![Daikin FTXTA30B2V1BW [4/12] About the unit](/views2/1785510/page4/bg4.png)
4 About the unit
Installation manual
4
FTXTA30B2V1B(W)(B)
Daikin room air conditioner
3P482320-12U – 2021.03
d Titanium apatite deodorising filter and silver particle filter
(Ag-ion filter)
e Indoor unit fixing screw (M4×12L). Refer to "8.3To fix the
unit on the mounting plate"[49].
f Dry battery AAA.LR03 (alkaline) for user interface
g User interface holder
h User interface
i Mounting plate
j Screw cover
k Spare SSID sticker with release paper (attached to the
unit)
▪ Spare SSID sticker. Do NOT throw away the spare sticker. Keep
it in a safe place in case it is needed in future (e.g. in case the
front grille was replaced attach it to the new front grille).
4 About the unit
WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
4.1 Operation range
Use the system in the following temperature and humidity ranges for
safe and effective operation.
Operation mode Operation range
Cooling
(a)(b)
▪ Outdoor temperature: –10~46°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
Heating
(a)
▪ Outdoor temperature: –25~24°C DB
▪ Indoor temperature: 10~30°C DB
Drying
(a)
▪ Outdoor temperature: –10~46°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
(a)
A safety device might stop the operation of the system if the unit
runs outside its operation range.
(b)
Condensation and water dripping might occur if the unit runs
outside its operation range.
4.2 About the wireless LAN
For detailed specifications, installation instructions, setting methods,
FAQ, declaration of conformity and the latest version of this manual,
visit app.daikineurope.com.
INFORMATION
▪ Daikin Industries Czech Republic s.r.o. declares that
the radio equipment type inside of this unit is in
compliance with Directive 2014/53/EU.
▪ This unit is considered as combined equipment
according to the definition of Directive 2014/53/EU.
4.2.1 Precautions when using the wireless LAN
Do NOT use near:
▪ Medical equipment. E.g. persons using cardiac pacemakers or
defibrillators. This product may cause electromagnetic
interference.
▪ Auto-control equipment. E.g. automatic doors or fire alarm
equipment. This product may cause faulty behaviour of the
equipment.
▪ Microwave oven. It may affect wireless LAN communications.
4.2.2 Basic parameters
Parameter Value
Frequency range 2400MHz~2483.5MHz
Radio protocol IEEE 802.11b/g/n
Radio frequency channel 1~11
Output power 0dBm~18dBm
Effective radiated power 17dBm (11b) / 13dBm (11g) /
12dBm (11n)
Power supply DC 3.3 V / 500 mA
5 Unit installation
INFORMATION
If you are not sure how to open or close parts of the unit
(front panel, electrical wiring box, front grille…) refer to the
installer reference guide of the unit for opening and closing
procedures.
WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
5.1 Preparing the installation site
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (e.g. open flames, an operating
gas appliance, or an operating electric heater). The room
size shall be as specified in the General safety precaution.
5.1.1 Installation site requirements of the
indoor unit
INFORMATION
The sound pressure level is less than 70dBA.
▪ Air flow. Make sure nothing blocks the air flow.
▪ Drainage. Make sure condensation water can be evacuated
properly.
▪ Wall insulation. When conditions in the wall exceed 30°C and a
relative humidity of 80%, or when fresh air is inducted into the
wall, then additional insulation is required (minimum 10 mm
thickness, polyethylene foam).
▪ Wall strength. Check whether the wall or the floor is strong
enough to support the weight of the unit. If there is a risk, reinforce
the wall or the floor before installing the unit.
▪ Spacing. Install the unit at least 1.8m from the floor and keep the
following requirements in mind for distances from the walls and
the ceiling:
Содержание
- Daikin room air conditioner 1
- Ftxta30b2v1bw ftxta30b2v1bb 1
- Installation manual 1
- A subset of the latest technical data is available on the regional 2
- About the box 3 2
- About the documentation 2
- About the documentation 2 2
- About the unit 4 2
- About this document 2
- Always observe the following safety instructions and regulations 2
- And manuals product information 2
- Authorised installers 2
- Business portal authentication required 2
- Commissioning 10 2
- Configuration 9 2
- Daikin website publicly accessible 2
- Disposal 10 2
- Documentation set 2
- Electrical installation 7 2
- Finishing the indoor unit installation 8 2
- Format digital files on http www daikineurope com support 2
- Format paper in the box of the indoor unit 2
- General safety precautions 2
- Indoor unit installation manual 2
- Information 2
- Installation instructions 2
- Installation manual 2
- Installation shall be done by an installer the choice of materials and installation shall comply with the applicable legislation in europe en378 is the applicable standard 2
- Installer reference guide 2
- Latest revisions of the supplied documentation may be available on the regional daikin website or via your dealer 2
- Make sure installation servicing maintenance repair and applied materials follow the instructions from daikin and in addition comply with applicable legislation and are performed by qualified persons only in europe and areas where iec standards apply en iec 60335 2 40 is the applicable standard 2
- Make sure that the user has the printed documentation and ask him her to keep it for future reference 2
- Piping installation 6 2
- Preparation of the installation good practices reference data 2
- Safety instructions that you must read before installing 2
- Specific installer safety instructions 2
- Specific installer safety instructions 2 2
- Table of contents 2
- Target audience 2
- Technical data 10 2
- Technical engineering data 2
- The full set of latest technical data is available on the daikin 2
- The original documentation is written in english all other languages are translations 2
- This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons 2
- This document is part of a documentation set the complete set consists of 2
- Unit installation 4 2
- Unit installation see 5 unit installation 4 4 2
- Warning 2
- About the box 3
- Indoor unit 3
- To remove the accessories from the indoor unit 3
- About the unit 4
- About the wireless lan 4
- Basic parameters 4
- Installation site requirements of the indoor unit 4
- Operation range 4
- Precautions when using the wireless lan 4
- Preparing the installation site 4
- Unit installation 4
- Mounting the indoor unit 5
- To drill a wall hole 5
- To install the mounting plate 5
- Unit installation 5
- Connecting the drain piping 6
- Piping installation 6
- Preparing refrigerant piping 6
- Refrigerant piping requirements 6
- To check for water leaks 6
- To connect the piping on left side left back or left bottom 6
- To connect the piping on right side right back or right bottom 6
- To remove the pipe port cover 6
- Connecting the refrigerant piping 7
- Electrical installation 7
- Refrigerant piping diameter 7
- Refrigerant piping insulation 7
- Refrigerant piping material 7
- Specifications of standard wiring components 7
- To connect the refrigerant piping to the indoor unit 7
- Finishing the indoor unit installation 8
- To connect optional accessories wired user interface central user interface etc 8
- To connect the electrical wiring to the indoor unit 8
- To insulate the drain piping refrigerant piping and interconnection cable 8
- Configuration 9
- To fix the unit on the mounting plate 9
- To pass the pipes through the wall hole 9
- To set a different address 9
- Checklist before commissioning 10
- Commissioning 10
- Disposal 10
- Technical data 10
- To perform a test run 10
- To perform a test run using the user interface 10
- Unified wiring diagram legend 10
- Wiring diagram 10
- Technical data 11
Похожие устройства
- Daikin FTXTA30B2V1BW Инструкция по эксплуатации
- Daikin FTXTA30B2V1BW Справочник пользователя
- Daikin ARXM25M3V1B9 Инструкция по монтажу
- Daikin ARXM35M3V1B9 Инструкция по монтажу
- Daikin ATXC20CV1B Инструкция по монтажу
- Daikin ATXC20CV1B Инструкция по эксплуатации
- Daikin ATXC25CV1B Инструкция по монтажу
- Daikin ATXC25CV1B Инструкция по эксплуатации
- Daikin ATXC35CV1B Инструкция по монтажу
- Daikin ATXC35CV1B Инструкция по эксплуатации
- ПКБ АРМА ДША-А14,4В3,0-2-2 Инструкция по эксплуатации
- ПКБ АРМА ДШУА-А18В1,5-2-2 Инструкция по эксплуатации
- ПКБ АРМА ДШУА-С18В2,0-2-2 Инструкция по эксплуатации
- ПКБ АРМА ДШУА-С18В3,0-1-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A1150-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-А900-1 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A720-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A1050-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A1150-1 Инструкция по эксплуатации
- ПКБ АРМА Пэ-Н820 Инструкция по эксплуатации