Daikin FTXTA30B2V1BW [8/20] Airflow direction
![Daikin FTXTA30B2V1BW [8/20] Airflow direction](/views2/1785511/page8/bg8.png)
5 Operation
Operation manual
8
FTXTA30B2V1B(W)(B)
Daikin room air conditioner
3P485919-13U – 2021.03
5.4 Airflow direction
When. Adjust the airflow direction as desired.
What. The system directs the airflow differently, depending on the
user selection (swinging or fixed position). It does so by moving
horizontal blades (flaps) or vertical blades (louvers).
Setting Airflow direction
Vertical automatic
swing
Moves up and down.
Horizontal
automatic swing
Moves from side to side.
+ 3-D airflow
direction
Moves alternately up and down and
from side to side
[—] Stays in a fixed position.
CAUTION
ALWAYS use a user interface to adjust the position of the
flaps and louvers. When the flaps and louvers are swinging
and you move them forcibly by hand, the mechanism will
break.
The movable range of the flap varies according to the operation
mode. The flap will stop at the upper position when the airflow rate is
changed to low during the up and down swing setting.
5.4.1 To adjust vertical airflow direction
1 Press .
Result: appears on the LCD. The flaps (horizontal blades)
will begin to swing.
2 To use fixed position, press when the flaps reach the
desired position.
Result: disappears from the LCD. The flaps will stop
moving.
5.4.2 To adjust horizontal airflow direction
1 Press .
Result: appears on the LCD. The louvers (vertical
blades) will begin to swing.
2 To use fixed position, press when the louvers reach the
desired position.
Result: disappears from the LCD. The louvers will stop
moving.
INFORMATION
When the unit is installed in a corner of a room, the
direction of the louvers should be facing away from the
wall. Efficiency will drop if a wall blocks the air.
5.4.3 To use 3-D airflow direction
1 Press and .
Result: and appear on the LCD. The flaps (horizontal
blades) and louvers (vertical blades) will begin to swing.
2 To use fixed position, press and when the flaps
and louvers reach the desired position.
Result: and disappear from the LCD. The flaps and
the louvers will stop moving.
5.5 Comfort airflow and Intelligent eye
operation
You can use Comfort and Intelligent eye operation separately, or
combine them.
5.5.1 Comfort airflow operation
The unit will automatically change the direction of the airflow to heat
up or cool down the room more effectively. Direct airflow from the
unit will be less noticeable.
a
b
c
a Flap position in cooling and dry operation
b Flap range in heating operation (vertical airflow ON)
c Flap position in heating operation (vertical airflow OFF)
In cooling and drying
The airflow direction will change to spread the air along the ceiling.
Comfort airflow ON Comfort airflow OFF
In heating
The airflow direction will change to spread the air along the floor.
The unit detects the room and floor temperature and automatically
selects 1 of the 3 airflow directions.
Warming up Downward direction Vertical airflow
direction
INFORMATION
If you want to deactivate the Vertical airflow function (e.g.
in case there is furniture or another object under the unit),
refer to "To turn ON/OFF vertical airflow function" [4 8]. If
the Vertical airflow function is deactivated, the airflow will
be set to downward direction.
INFORMATION
Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If the vertical automatic swing is selected, Comfort airflow
operation will be cancelled.
To turn ON/OFF vertical airflow function
1 Press for at least 2seconds.
Result: The menu appears on the display.
2 Press or to change the menu screen.
Result: The menu appears on the display.
Содержание
- Daikin room air conditioner 1
- Ftxta30b2v1bw ftxta30b2v1bb 1
- Operation manual 1
- About the documentation 2
- About the documentation 2 2
- About the system 4 2
- About this document 2
- Always observe the following safety instructions and regulations 2
- And manuals product information 2
- Before operation 5 2
- Detailed step by step instructions and background information 2
- Disposal 18 2
- Documentation set 2
- End users 2
- Energy saving and optimum operation 14 2
- For basic and advanced usage 2
- Format digital files on http www daikineurope com support 2
- Format paper in the box of the indoor unit 2
- General safety precautions 2
- Information 2
- Keep the documentation for future reference 2
- Latest revisions of the supplied documentation may be available on the regional daikin website or via your installer 2
- Maintenance and service 15 2
- Operation 7 2
- Operation manual 2
- Quick guide for basic usage 2
- Safety instructions that you must read before operating your 2
- System 2
- Table of contents 2
- Target audience 2
- Thank you for purchasing this product please 2
- The original documentation is written in english all other languages are translations 2
- This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons 2
- This document is part of a documentation set the complete set consists of 2
- Troubleshooting 18 2
- User reference guide 2
- User safety instructions 2
- User safety instructions 2 2
- Instructions for safe operation 3
- About the system 4
- About the user interface 4
- Indoor unit 4
- Indoor unit display 4
- Before operation 5
- Components user interface 5
- To insert the batteries 5
- To mount the user interface holder 5
- To operate the user interface 5
- Before operation 6
- To change indoor unit position setting 6
- To set the brightness of the indoor unit display 6
- To set the clock 6
- To turn on the power supply 6
- Airflow rate 7
- Operation 7
- Operation mode and temperature setpoint 7
- Operation range 7
- To adjust the airflow rate 7
- To start stop operation mode and to set the temperature 7
- Airflow direction 8
- Comfort airflow and intelligent eye operation 8
- Comfort airflow operation 8
- Operation 8
- To adjust horizontal airflow direction 8
- To adjust vertical airflow direction 8
- To turn on off vertical airflow function 8
- To use 3 d airflow direction 8
- Econo and outdoor unit quiet operation 9
- Econo operation 9
- Intelligent eye operation 9
- Operation 9
- Outdoor unit quiet operation 9
- Powerful operation 9
- To start stop comfort and intelligent eye operation 9
- To start stop econo and outdoor unit quiet operation 9
- To start stop powerful operation 9
- Fireplace logic operation 10
- Flash streamer air cleaning operation 10
- Flash streamer and fireplace logic operation 10
- Off on timer operation 10
- Operation 10
- To start stop flash streamer and fireplace logic operation 10
- To start stop off timer operation 10
- To start stop on timer operation 10
- Operation 11
- To combine off timer and on timer 11
- To set weekly timer operation 11
- Weekly timer operation 11
- Operation 12
- To confirm reservations 12
- To copy reservations 12
- To deactivate and reactivate weekly timer operation 12
- To delete a reservation for each day of the week 12
- To delete individual reservations 12
- To delete reservations 12
- Operation 13
- Precautions when using the wireless lan 13
- To confirm the wireless lan connection status 13
- To connect the wireless lan to your home network 13
- To delete all reservations 13
- To install the daikin residential controller application 13
- To set the wireless connection 13
- Wireless lan connection 13
- Energy saving and optimum operation 14
- To reset the connection setting to the factory default 14
- To turn off the wireless lan connection 14
- Maintenance and service 15
- Overview maintenance and service 15
- To clean the front panel 15
- To clean the indoor unit and user interface 15
- To open the front panel 15
- Maintenance and service 16
- To clean the air filters 16
- To clean the titanium apatite deodorising filter and the silver particle filter ag ion filter 16
- Maintenance and service 17
- To close the front panel 17
- To remove the front panel 17
- To replace the titanium apatite deodorising filter and the silver particle filter ag ion filter 17
- To take following items into account before a long idle period 17
- Disposal 18
- Troubleshooting 18
- Winter season 18
Похожие устройства
- Daikin FTXTA30B2V1BW Справочник пользователя
- Daikin ARXM25M3V1B9 Инструкция по монтажу
- Daikin ARXM35M3V1B9 Инструкция по монтажу
- Daikin ATXC20CV1B Инструкция по монтажу
- Daikin ATXC20CV1B Инструкция по эксплуатации
- Daikin ATXC25CV1B Инструкция по монтажу
- Daikin ATXC25CV1B Инструкция по эксплуатации
- Daikin ATXC35CV1B Инструкция по монтажу
- Daikin ATXC35CV1B Инструкция по эксплуатации
- ПКБ АРМА ДША-А14,4В3,0-2-2 Инструкция по эксплуатации
- ПКБ АРМА ДШУА-А18В1,5-2-2 Инструкция по эксплуатации
- ПКБ АРМА ДШУА-С18В2,0-2-2 Инструкция по эксплуатации
- ПКБ АРМА ДШУА-С18В3,0-1-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A1150-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-А900-1 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A720-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A1050-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A1150-1 Инструкция по эксплуатации
- ПКБ АРМА Пэ-Н820 Инструкция по эксплуатации
- ПКБ АРМА Пэ-Т1201-20 Инструкция по эксплуатации