Daikin FTYN25LV1B [10/48] A short beep and two consecutive beeps indicate non corresponding codes 2 to cancel the code display hold the on timer cancel button or off timer cancel button

Содержание

ERROR CODE MEANING H9 OUTDOOR AIR THERMISTOR SHORT OPEN JI PRESSURE SENSOR ERROR J3 COMPRESSOR DISCHARGE PIPE THERMISTOR SHORT OPEN MISPLACED J5 SUCTION PIPE THERMISTOR SHORT OPEN J6 OUTDOOR HEAT EXCHANGER THERMISTOR SHORT OPEN J7 SUBCOOLING HEAT EXCHANGER THERMISTOR SHORT OPEN J8 LIQUID PIPE THERMISTOR SHORT OPEN J9 GAS PIPE THERMISTOR SHORT OPEN LI INVERTER OUTDOOR PCB ERROR L3 OUTDOOR CONTROL BOX OVERHEAT L4 HEAT SINK OVERHEAT L5 IPM ERROR IGBT ERROR L8 INVERTER COMPRESSOR OVERCURRENT L9 COMPRESSOR OVERCURRENT PREVENTION LC COMMUNICATION ERROR OUTDOOR CONTROL PCB AND INVERTER PCB Pl OPEN PHASE OR VOLTAGE UNBALANCE P4 HEAT SINK THERMISTOR SHORT OPEN PJ CAPACITY SETTING ERROR UO INSUFFICIENT GAS U2 DC VOLTAGE OUT OF RANGE U4 COMMUNICATION ERROR U7 COMMUNICATION ERROR OUTDOOR CONTROL PCB AND IPM PCB UA INSTALLATION ERROR UF PIPING WIRING INSTALLATION MISMATCH WRONG WIRING INSUFFICIENT GAS UH ANTIFREEZE OTHER ROOMS NOTE 1 A short beep and two consecutive beeps indicate non corresponding codes 2 To cancel the code display hold the ON TIMER CANCEL button or OFF TIMER CANCEL button down for 5 seconds The code display also cancel itself if the button is not pressed for 1 minute 4