Daikin FTYN35LV1B [9/152] Hole with cone drill

Содержание

Mounting Installation Plate Hole with cone drill English Ensure that the wall is strong enough to withstand the weight of the unit Otherwise it is necessary to reinforce the wall with plates beams or pillars Use the level gauge for horizontal mounting and fix it with 5 suitable screws for FTYN 20 25 35 and 7 suitable screws for FTYN 50 60 In case the rear piping draws out drill a hole 65mm in diameter with a cone drill slightly lower on the outside wall see figure Mount The Unit Onto The Installation Plate Hook the indoor unit onto the upper portion of the installation plate Engage the two hooks at the rear top of the indoor unit with the upper edge of the installation plate Ensure that the hooks are properly seated on the installation plate by moving it to the left and right How To Attach The Indoor Unit Hook the claw s of the bottom frame to the mounting plate FTYN 20 25 35 ALTERNATIVE INSTALLATION PLATE How To Remove The Indoor Unit Mourning plate Push up the marked area at the lower part of the front grille to release the claws Mounting plate fixing screw Recommended Mounting Plate Retention Spots And Dimensions Hand indoor unit s hook here When stripping the ends of interconnecting wires advance bind right ends wires with insulating tape Mounting plate Wire guide Water Drainage Piping Hie indoor drain pipe must be in a smooth drainage Avoid situations that water to leak FTYN 20 25 35 ALTERNATIVE INSTALLATION PLATE Rixanmcafai mctintinj plate trtentkm rants 5 Spot ill all downward gradient for are likely to cause Water Drainage the wall hot 065tnm Dramkwpo tka Gæ pipe OH All dimensions are in mm A CAUTION Do not install the unit at altitude over 2000m for both indoor outdoor 1 7

Скачать