Daikin RHBH04CB [14/28] Operation

Daikin RHBX04CB [14/28] Operation
4 Operation
User reference guide
14
RHBH/X04~16CB
ROTEX HPSU low temperature Bi‑bloc
4P384968-1B – 2017.04
4.6 Advanced usage
4.6.1 About changing the user permission level
The amount of information you can read out in the menu structure
depends on your user permission level:
End user (= default)
Adv. end user: You can read out more information.
To set the user permission level to Advanced end user
1 Go to the main menu or any of its submenus: .
2 Press for more than 4seconds.
Result: The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu title.
The user permission level will stay in Adv. end user until set
otherwise.
To set the user permission level to End user
1 Press for more than 4 seconds.
Result: The user permission level switches to End user. The user
interface will return to the default home screen.
4.6.2 Using quiet mode
About quiet mode
You can use quiet mode to decrease the sound of the outdoor unit.
However, this also decreases the heating/cooling capacity of the
system. There are multiple quiet mode levels.
You can:
Completely deactivate quiet mode
Manually activate a quiet mode level until the next scheduled
action
Use and program a quiet mode schedule
Possible quiet mode levels
For RHBH/X04+08 + RHVH/X04+08
Level Description
Level 1 Least quiet. At colder ambient conditions,
reduced performance can occur.
Level 2 Medium quiet. Under all circumstances,
reduced performance is possible.
Level 3 Most quiet. Under all circumstances,
performance will be reduced.
For RHBH/X11+16 + RHVH/X11+16
Level Description
Level 1 Most quiet. Under all circumstances,
performance will be reduced.
To check if quiet mode is active
1 Press to go to one of the home pages.
2 If is displayed, quiet mode is active.
To use quiet mode
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [3]: > Quiet mode.
2 Do one of the following:
If you want to… Then…
Completely deactivate quiet
mode
Select Always OFF and press
.
If you want to… Then…
Manually activate a quiet mode
level
Select On and press .
Go to [7.4.4]: > User
settings > Preset values >
Quiet level.
Select a level and press .
Use and program a quiet mode
schedule
Select Automatic and press
.
Program a schedule. See
"4.7.2 Using and
programming schedules" on
page17.
Usage example: Baby is sleeping in the afternoon
If you are in the following situation:
You have programmed a quiet mode schedule:
During the night: Level 3 (=most quiet).
During the day: OFF to ensure the heating/cooling capacity of
the system.
However, during the afternoon the baby is sleeping and you want
it to be quiet.
Then you can do the following:
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [3]: > Quiet mode.
2 Select On and press .
3 Go to [7.4.4]: > User settings > Preset values > Quiet level.
4 Select Level 3 and press .
Advantage:
The outdoor unit runs in its most quiet level.
4.6.3 Using holiday mode
About holiday mode
During your holiday, you can use the holiday mode to deviate from
your normal schedules without having to change them. You can only
use holiday mode if temperature control = room thermostat control.
See also "4.4.3 Determining which temperature control you are
using"on page7.
Using holiday mode typically consists of the following stages:
1 Configuring the holiday for one of the following situations:
Situation Then…
You stay at home
during your holiday
You have to select a day: space
heating/cooling will be according to the
desired room temperature of the
selected day.
You go away during
your holiday
You have to configure space heating/
cooling settings.
Space heating/cooling will be
according to these settings.
Domestic hot water operation can
be turned ON or OFF. If you decide
to turn it OFF, disinfection mode will
remain active.
2 Activating the holiday mode.