Daikin RHBH11CB [2/9] P383508 1b 2017 4
![Daikin RHBH11CB [2/9] P383508 1b 2017 4](/views2/1786499/page2/bg2.png)
2/9
Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
User settings
└─ Preset values
└─ Room temperature
7.4.1.1 R/W [3-07]~[3-06], step: A.3.2.4
21°C
7.4.1.2 R/W [3-07]~[3-06], step: A.3.2.4
19°C
7.4.1.3 R/W [3-08]~[3-09], step: A.3.2.4
24°C
7.4.1.4 R/W [3-08]~[3-09], step: A.3.2.4
26°C
└─ LWT main
7.4.2.1 [8-09] R/W [9-01]~[9-00], step: 1°C
35°C
7.4.2.2 [8-0A] R/W [9-01]~[9-00], step: 1°C
33°C
7.4.2.3 [8-07] R/W [9-03]~[9-02], step: 1°C
18°C
7.4.2.4 [8-08] R/W [9-03]~[9-02], step: 1°C
20°C
7.4.2.5 R/W -10~10°C, step: 1°C
0°C
7.4.2.6 R/W -10~10°C, step: 1°C
-2°C
7.4.2.7 R/W -10~10°C, step: 1°C
0°C
7.4.2.8 R/W -10~10°C, step: 1°C
2°C
└─ Tank temperature
7.4.3.1 [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
7.4.3.2 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
7.4.3.3 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
└─ Quiet level
7.4.4 R/W
0: Level 1 (*6)
1: Level 2 (*5)
2: Level 3
└─ Electricity price
7.4.5.1 [C-0C]
[D-0C]
R/W 0,00~990/kWh
0/kWh
7.4.5.2 [C-0D]
[D-0D]
R/W 0,00~990/kWh
0/kWh
7.4.5.3 [C-0E]
[D-0E]
R/W 0,00~990/kWh
0/kWh
└─ Fuel price
7.4.6 R/W 0,00~990/kWh
0,00~290/MBtu
8,0/kWh
└─ Set weather dependent
└─ Main
└────────────────── Set weather-dependent heating
7.7.1.1 [1-00] Set weather-dependent heating Low ambient temp. for LWT main zone heating
WD curve.
R/W -40~5°C, step: 1°C
-10°C
7.7.1.1 [1-01] Set weather-dependent heating High ambient temp. for LWT main zone heating
WD curve.
R/W 10~25°C, step: 1°C
15°C
7.7.1.1 [1-02] Set weather-dependent heating Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~[9-00]°C, step: 1°C
35°C
7.7.1.1 [1-03] Set weather-dependent heating Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
R/W [9-01]~min(45, [9-00])°C , step: 1°C
25°C
└────────────────── Set weather-dependent cooling
7.7.1.2 [1-06] Set weather-dependent cooling Low ambient temp. for LWT main zone cooling
WD curve.
R/W 10~25°C, step: 1°C
20°C
7.7.1.2 [1-07] Set weather-dependent cooling High ambient temp. for LWT main zone cooling
WD curve.
R/W
25~43°C, step: 1°C
35°C
7.7.1.2 [1-08] Set weather-dependent cooling Leaving water value for low ambient temp. for
LWT main zone cooling WD curve.
R/W [9-03]~[9-02]°C, step: 1°C
22°C
7.7.1.2 [1-09] Set weather-dependent cooling Leaving water value for high ambient temp. for
LWT main zone cooling WD curve.
R/W [9-03]~[9-02]°C, step: 1°C
18°C
└─ Additional
└────────────────── Set weather-dependent heating
7.7.2.1 [0-00] Set weather-dependent heating Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
R/W [9-05]~min(45,[9-06])°C, step: 1°C
35°C
7.7.2.1 [0-01] Set weather-dependent heating Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
R/W [9-05]~[9-06]°C, step: 1°C
45°C
7.7.2.1 [0-02] Set weather-dependent heating High ambient temp. for LWT add zone heating
WD curve.
R/W 10~25°C, step: 1°C
15°C
7.7.2.1 [0-03] Set weather-dependent heating Low ambient temp. for LWT add zone heating
WD curve.
R/W -40~5°C, step: 1°C
-10°C
└────────────────── Set weather-dependent cooling
7.7.2.2 [0-04] Set weather-dependent cooling Leaving water value for high ambient temp. for
LWT add zone cooling WD curve.
R/W [9-07]~[9-08]°C, step: 1°C
8°C
7.7.2.2 [0-05] Set weather-dependent cooling Leaving water value for low ambient temp. for
LWT add zone cooling WD curve.
R/W [9-07]~[9-08]°C, step: 1°C
12°C
7.7.2.2 [0-06] Set weather-dependent cooling High ambient temp. for LWT add zone cooling
WD curve.
R/W 25~43°C, step: 1°C
35°C
7.7.2.2 [0-07] Set weather-dependent cooling Low ambient temp. for LWT add zone cooling
WD curve.
R/W 10~25°C, step: 1°C
20°C
Installer settings
└─ System layout
└─ Standard
A.2.1.1 [E-00] R/O 0~5
0: LT s
p
lit
A.2.1.2 [E-01] R/O 0: 8
1: 16
A.2.1.3 [E-02] R/O 0: Type 1
1: Type 2
A.2.1.4 [E-03] R/O 0: No BUH
1: 1 step
2: 2 steps
Indoor software type
Backup heater steps
High
Medium
Low
Unit type
Compressor type
Comfort (cooling)
Eco (cooling)
Storage comfort
Storage eco
Reheat
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
Comfort (heating)
Eco (heating)
Field settings table
Installer setting at variance with
default value
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
4P383508-1B - 2017.04
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*
Содержание
- Field settings table 1
- Id66f2 1
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 2
- Field settings table 2
- P383508 1b 2017 4 2
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4p383508 1b 2017 4 3
- Field settings table 3
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4
- Field settings table 4
- P383508 1b 2017 4 4
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4p383508 1b 2017 4 5
- Field settings table 5
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 6
- Field settings table 6
- P383508 1b 2017 4 6
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4p383508 1b 2017 4 7
- Field settings table 7
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 8
- Field settings table 8
- P383508 1b 2017 4 8
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4p383508 1b 2017 4 9
- Field settings table 9
Похожие устройства
- Daikin RHBH11CB Спецификация
- Daikin RHBH11CB Инструкция по эксплуатации
- Daikin RHBH11CB Руководство по эксплуатации
- Daikin RHBH11CB Инструкция по монтажу
- Daikin RHBH11CB Руководство по монтажу
- Daikin RHBH16CB Технические данные
- Daikin RHBH16CB Спецификация
- Daikin RHBH16CB Инструкция по эксплуатации
- Daikin RHBH16CB Руководство по эксплуатации
- Daikin RHBH16CB Инструкция по монтажу
- Daikin RHBH16CB Руководство по монтажу
- Daikin RHBX04CB Технические данные
- Daikin RHBX04CB Спецификация
- Daikin RHBX04CB Инструкция по эксплуатации
- Daikin RHBX04CB Руководство по эксплуатации
- Daikin RHBX04CB Инструкция по монтажу
- Daikin RHBX04CB Руководство по монтажу
- Daikin RHBX08CB Технические данные
- Daikin RHBX08CB Спецификация
- Daikin RHBX08CB Инструкция по эксплуатации