Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
A.6.3.2 [4-09] R/W 0: Current
1: Powe
r
A.6.3.3 [5-05] R/W 0~50 A, step: 1 A
50
A
A.6.3.4 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.5.1 [5-05] Amp. limits for DI Limit DI1 R/W 0~50 A, step: 1 A
50
A
A.6.3.5.2 [5-06] Amp. limits for DI Limit DI2 R/W 0~50 A, step: 1 A
50
A
A.6.3.5.3 [5-07] Amp. limits for DI Limit DI3 R/W 0~50 A, step: 1 A
50
A
A.6.3.5.4 [5-08] Amp. limits for DI Limit DI4 R/W 0~50 A, step: 1 A
50
A
A.6.3.6.1 [5-09] kW limits for DI Limit DI1 R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.2 [5-0A] kW limits for DI Limit DI2 R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.3 [5-0B] kW limits for DI Limit DI3 R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.4 [5-0C] kW limits for DI Limit DI4 R/W 0~20 kW, step: 0,5 kW
20 kW
A.6.3.7 [4-01] R/W
0: None
1: BSH
2: BUH
└─ Averaging time
A.6.4 [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─ Ext amb. sensor offset
A.6.5 [2-0B] R/W -5~5°C, step: 0,5°C
0°C
└─ Boiler efficiency
A.6.A [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
y
low
└─ Emergency
A.6.C R/W
0: Manual
1: Automatic
└─ Overview settings
A.8 [0-00] R/W [9-05]~min(45,[9-06])°C, step: 1°C
35°C
A.8 [0-01] R/W [9-05]~[9-06]°C, step: 1°C
45°C
A.8 [0-02] R/W 10~25°C, step: 1°C
15°C
A.8 [0-03] R/W -40~5°C, step: 1°C
-10°C
A.8 [0-04] R/W [9-07]~[9-08]°C, step: 1°C
8°C
A.8 [0-05] R/W [9-07]~[9-08]°C, step: 1°C
12°C
A.8 [0-06] R/W 25~43°C, step: 1°C
35°C
A.8 [0-07] R/W 10~25°C, step: 1°C
20°C
A.8 [0-0B] R/W 35~[6-0E]°C, step: 1°C
55°C
A.8 [0-0C] R/W 45~[6-0E]°C, step: 1°C
60°C
A.8 [0-0D] R/W 10~25°C, step: 1°C
15°C
A.8 [0-0E] R/W -40~5°C, step: 1°C
-10°C
A.8 [1-00] R/W -40~5°C, step: 1°C
-10°C
A.8 [1-01] R/W 10~25°C, step: 1°C
15°C
A.8 [1-02] R/W
[9-01]~[9-00], step: 1°C
35°C
A.8 [1-03] R/W [9-01]~min(45, [9-00])°C , step: 1°C
25°C
A.8 [1-04] R/W 0: Disabled
1: Enabled
A.8 [1-05] R/W 0: Disabled
1: Enabled
A.8 [1-06] R/W 10~25°C, step: 1°C
20°C
A.8 [1-07] R/W
25~43°C, step: 1°C
35°C
A.8 [1-08] R/W [9-03]~[9-02]°C, step: 1°C
22°C
A.8 [1-09] R/W [9-03]~[9-02]°C, step: 1°C
18°C
A.8 [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
A.8 [2-00] R/W 0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunda
y
A.8 [2-01] R/W 0: No
1: Yes
When should the disinfection function be executed?
Should the disinfection function be executed?
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
What is the averaging time for the outdoor temp?
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
Weather dependent cooling of the main leaving water temperature zone.
Weather dependent cooling of the additional leaving water temperature zone
Low ambient temp. for LWT main zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Low ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
High ambient temp. for LWT add zone cooling WD curve.
kW value
Priority
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Type
Amp. value
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*
4P383508-1B - 2017.04
Содержание
- Field settings table 1
- Id66f2 1
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 2
- Field settings table 2
- P383508 1b 2017 4 2
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4p383508 1b 2017 4 3
- Field settings table 3
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4
- Field settings table 4
- P383508 1b 2017 4 4
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4p383508 1b 2017 4 5
- Field settings table 5
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 6
- Field settings table 6
- P383508 1b 2017 4 6
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4p383508 1b 2017 4 7
- Field settings table 7
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 8
- Field settings table 8
- P383508 1b 2017 4 8
- 1 hb _ 2 hv _ 3 3v_ 4 9w_ 5 04 08 _ 6 11 16 4p383508 1b 2017 4 9
- Field settings table 9
Похожие устройства
- Daikin RHBH11CB Спецификация
- Daikin RHBH11CB Инструкция по эксплуатации
- Daikin RHBH11CB Руководство по эксплуатации
- Daikin RHBH11CB Инструкция по монтажу
- Daikin RHBH11CB Руководство по монтажу
- Daikin RHBH16CB Технические данные
- Daikin RHBH16CB Спецификация
- Daikin RHBH16CB Инструкция по эксплуатации
- Daikin RHBH16CB Руководство по эксплуатации
- Daikin RHBH16CB Инструкция по монтажу
- Daikin RHBH16CB Руководство по монтажу
- Daikin RHBX04CB Технические данные
- Daikin RHBX04CB Спецификация
- Daikin RHBX04CB Инструкция по эксплуатации
- Daikin RHBX04CB Руководство по эксплуатации
- Daikin RHBX04CB Инструкция по монтажу
- Daikin RHBX04CB Руководство по монтажу
- Daikin RHBX08CB Технические данные
- Daikin RHBX08CB Спецификация
- Daikin RHBX08CB Инструкция по эксплуатации