Daikin RHBH16CB [9/104] Identification

Daikin RHBH16CB [9/104] Identification
4 About the units and options
Installer reference guide
9
RRLQ011~016CA + RHBH/X11+16CB
ROTEX HPSU low temperature Bi‑bloc
4P384980-1C – 2017.04
Identifying the outdoor unit
Identifying the indoor unit
Combining outdoor and indoor units
Combining the outdoor unit with options
Combining the indoor unit with options
4.2 Identification
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
4.2.1 Identification label: Outdoor unit
Location
Model identification
RRLQ: Contains components (insulation, bottom plate heater,…) to
prevent freeze-up in areas with low ambient temperature and high
humidity.
Example: RRLQ011CAW1
Code Explanation
RR Split outdoor pair heat pump
L Low water temperature – ambient zone:
−⁠10⁠~⁠−⁠20°C
Q Refrigerant R410A
011 Capacity class
CA Model series
W1 Power supply
4.2.2 Identification label: Indoor unit
Location
Model identification
Example: RHBH04CB3V
Code Description
R ROTEX model
HB Wall-mounted indoor unit
H H=Heating only
X=Heating/cooling
04 Capacity class
Code Description
CB Model series
3V Backup heater model
4.3 Combining units and options
4.3.1 Possible options for the outdoor unit
Demand PCB (KRP58M51) (only for RRLQ)
Limits the maximum current. However, this also decreases the
heating/cooling capacity of the system.
Only the "Setting of demand running" function of the demand PCB
is applicable.
For installation instructions, see the installation manual of the
demand PCB.
Snow cover (RK016SNC) (only for RRLQ)
Prevents the outdoor unit from being snowed up.
Recommended in areas with low ambient temperatures or heavy
snowfall.
For installation instructions, see the installation manual of the
snow cover.
4.3.2 Possible options for the indoor unit
User interface (RKRUCBL*)
The user interface and a possible additional user interface are
available as an option.
The additional user interface can be connected:
To have both:
control close to the indoor unit,
room thermostat functionality in the principal space to be
heated.
To have an interface containing other languages.
Following user interfaces are available:
RKRUCBL1 contains following languages: German, French,
Dutch, Italian.
RKRUCBL2 contains following languages: English, Swedish,
Norwegian, Finnish.
RKRUCBL3 contains following languages: English, Spanish,
Greek, Portuguese.
RKRUCBL4 contains following languages: English, Turkish,
Polish, Romanian.
RKRUCBL5 contains following languages: German, Czech,
Slovenian, Slovakian.
RKRUCBL6 contains following languages: English, Croatian,
Hungarian, Estonian.
RKRUCBL7 contains following languages: English, German,
Russian, Danish.
Languages on the user interface can be uploaded by PC software or
copied from an user interface to the other.
For installation instructions, see "7.9.11 To connect the user
interface"on page44.
Room thermostat (RKRTWA, RKRTR1, RTRNETA)
You can connect an optional room thermostat to the indoor unit. This
thermostat can either be wired (RKRTWA) or wireless (RKRTR1 and
RTRNETA). Thermostat RTRNETA can only be used in heating-only
systems.
For installation instructions, see the installation manual of the room
thermostat and addendum book for optional equipment.