Daikin EHVH08SU18DA6V7 [3/36] General safety precautions
![Daikin EHVH08SU23DA6V7 [3/36] General safety precautions](/views2/1787401/page3/bg3.png)
Table of contents
Installation manual
3
EHVH04+08SU18+23DA6V7
Daikin Altherma 3 R F
4P619456-1 – 2020.03
Table of contents
1 About the documentation 3
1.1 About this document.................................................................. 3
2 About the box 4
2.1 Indoor unit ................................................................................. 4
2.1.1 To remove the accessories from the indoor unit......... 4
2.1.2 To handle the indoor unit ............................................ 4
2.2 Domestic hot water tank kit ....................................................... 4
2.2.1 To remove the accessories from the domestic hot
water tank kit............................................................... 4
2.3 Checklist for the required DHW accessories............................. 4
3 Preparation 5
3.1 Preparing the installation site .................................................... 5
3.1.1 Installation site requirements of the indoor unit .......... 5
3.2 Preparing water piping .............................................................. 7
3.2.1 To check the water volume and flow rate ................... 7
3.3 Preparing electrical wiring ......................................................... 7
3.3.1 Overview of electrical connections for external and
internal actuators ........................................................ 7
4 Installation 7
4.1 Opening the units ...................................................................... 7
4.1.1 To open the indoor unit............................................... 7
4.1.2 To lower the switch box on the indoor unit.................. 8
4.2 Mounting the indoor unit............................................................ 9
4.2.1 To install the indoor unit.............................................. 9
4.2.2 To connect the drain hose to the drain ....................... 9
4.3 Connecting refrigerant piping .................................................... 9
4.3.1 To connect the refrigerant piping to the indoor unit .... 9
4.4 Connecting water piping............................................................ 10
4.4.1 To connect the water piping........................................ 10
4.4.2 To connect the water piping for domestic hot water ... 10
4.4.3 To connect the recirculation piping ............................. 11
4.4.4 To fill the water circuit ................................................. 12
4.4.5 To fill the domestic hot water tank .............................. 12
4.4.6 To insulate the water piping........................................ 12
4.5 Connecting the electrical wiring................................................. 12
4.5.1 About electrical compliance ........................................ 12
4.5.2 To connect the electrical wiring to the indoor unit....... 12
4.5.3 To connect the main power supply ............................. 13
4.5.4 To connect the backup heater power supply .............. 13
4.5.5 To connect the shut-off valve...................................... 14
4.5.6 To connect the electricity meters ................................ 14
4.5.7 To connect the domestic hot water pump................... 14
4.5.8 To connect the alarm output ....................................... 15
4.5.9 To connect the space cooling/heating ON/OFF
output .......................................................................... 15
4.5.10 To connect the changeover to external heat source... 15
4.5.11 To connect the power consumption digital inputs....... 15
4.5.12 To connect the safety thermostat (normally closed
contact) ....................................................................... 15
4.6 Finishing the indoor unit installation .......................................... 16
4.6.1 To close the indoor unit............................................... 16
5 Configuration 16
5.1 Overview: Configuration ............................................................ 16
5.1.1 To access the most used commands ......................... 16
5.2 Configuration wizard.................................................................. 17
5.2.1 Configuration wizard: Language ................................. 17
5.2.2 Configuration wizard: Time and date .......................... 17
5.2.3 Configuration wizard: System ..................................... 17
5.2.4 Configuration wizard: Backup heater.......................... 18
5.2.5 Configuration wizard: Main zone................................. 19
5.2.6 Configuration wizard: Additional zone......................... 20
5.2.7 Detailed screen with weather-dependent curve.......... 20
5.2.8 Configuration wizard: Tank .......................................... 21
5.3 Settings menu ............................................................................ 22
5.3.1 Main zone .................................................................... 22
5.3.2 Additional zone ............................................................ 22
5.3.3 Information................................................................... 22
5.4 Menu structure: Overview installer settings................................ 23
6 Commissioning 24
6.1 Checklist before commissioning................................................. 24
6.2 Checklist during commissioning ................................................. 24
6.2.1 To check the minimum flow rate .................................. 24
6.2.2 To perform an air purge ............................................... 24
6.2.3 To perform an operation test run ................................. 25
6.2.4 To perform an actuator test run ................................... 25
6.2.5 To perform an underfloor heating screed dryout.......... 25
7 Hand-over to the user 25
8 Technical data 27
8.1 Piping diagram: Indoor unit ........................................................ 27
8.2 Wiring diagram: Indoor unit ........................................................ 28
8.3 Table 1 – Maximum refrigerant charge allowed in a room:
indoor unit................................................................................... 31
8.4 Table 2 – Minimum floor area: indoor unit.................................. 31
8.5 Table 3 – Minimum venting opening area for natural
ventilation: indoor unit ................................................................ 31
8.6 Technical specifications: Domestic hot water tank..................... 31
8.6.1 Test results in accordance with EN12897 (2016) ........ 31
8.6.2 Warning label............................................................... 32
1 About the documentation
1.1 About this document
Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: Paper (in the box of the indoor unit)
▪ Indoor unit installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the indoor unit)
▪ Outdoor unit installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the outdoor unit)
▪ Installer reference guide:
▪ Preparation of the installation, good practices, reference data,…
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
▪ Addendum book for optional equipment:
▪ Additional info about how to install optional equipment
▪ Format: Paper (in the box of the indoor unit) + Digital files on
http://www.daikineurope.com/support-and-manuals/product-
information/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
Содержание
- Daikin altherma 3 r f 1
- Installation manual 1
- 551 emc 2
- Daikin europe n v 2
- Daikin tcf 34a10 05 2020 2
- Dekra nb0344 2
- Director 2
- Ehvh04su18da6v7 ehvh04su23da6v7 2
- Ehvh08su18da6v7 ehvh08su23da6v7 2
- Electromagnetic compatibility 2014 30 eu 2
- En60335 2 40 2
- Hiromitsu iwasaki 2
- Installation manual 2
- Low voltage 2014 35 eu 2
- Ostend 2nd of june 2020 2
- P507286 10c 2
- About the box 4 3
- About the documentation 3
- About the documentation 3 3
- About this document 3
- Addendum book for optional equipment 3
- Additional info about how to install optional equipment 3
- And manuals product information 3
- Authorised installers 3
- Commissioning 24 3
- Configuration 16 3
- Documentation set 3
- Format digital files on http www daikineurope com support 3
- Format paper in the box of the indoor unit 3
- Format paper in the box of the indoor unit digital files on 3
- Format paper in the box of the outdoor unit 3
- General safety precautions 3
- Hand over to the user 25 3
- Http www daikineurope com support and manuals product information 3
- Indoor unit installation manual 3
- Installation 7 3
- Installation instructions 3
- Installer reference guide 3
- Latest revisions of the supplied documentation may be available on the regional daikin website or via your dealer 3
- Outdoor unit installation manual 3
- Preparation 5 3
- Preparation of the installation good practices reference data 3
- Safety instructions that you must read before installing 3
- Table of contents 3
- Target audience 3
- Technical data 27 3
- The original documentation is written in english all other languages are translations 3
- This document is part of a documentation set the complete set consists of 3
- A b c d e 4
- A subset of the latest technical data is available on the regional 4
- About the box 4
- Adaptor 22 mm 3 4 female bsp 4
- All piping must be installed according to section g3 of the building regulations 4
- Business portal authentication required 4
- Checklist for the required dhw accessories 4
- Daikin website publicly accessible 4
- Delivered with domestic hot water tank kit 4
- Delivered with indoor unit 4
- Domestic hot water tank kit 4
- Expansion vessel of 18 l 3 4 male bsp 4
- For installation compliant with section g3 of the building regulations you must verify that the following accessories are present 4
- Indoor unit 4
- Information 4
- Instruction sheet 4
- J k l f g h i 4
- Notice 4
- Pressure reducing valve pressure relief valve combination 4
- T piece 22 mm 22 mm 22 mm 4
- Technical engineering data 4
- The full set of latest technical data is available on the daikin 4
- This unit has been tested and approved according to bs en12897 2016 4
- To handle the indoor unit 4
- To remove the accessories from the domestic hot water tank kit 4
- To remove the accessories from the indoor unit 4
- Tundish 15 mm inlet 22 mm outlet 4
- Use the handles at the back and at the bottom to carry the unit 4
- Wall mounting set for expansion vessel 4
- Installation site requirements of the indoor unit 5
- Preparation 5
- Preparing the installation site 5
- 1 4 kg i e if the piping length is 27 m are not subjected to any requirements to the installation room 6
- Daikin altherma 3 r f 4p619456 1 2020 3 6
- Ehvh04 08su18 23da6v7 6
- If the total refrigerant charge in the system is 1 4 kg i e if the piping length is 27 m you need to comply with the minimum floor area requirements as described in the following flow chart the flow chart uses the following tables 8 table 1 maximum refrigerant charge allowed in a room indoor unit 4 31 8 table 2 minimum floor area indoor unit 4 31 and 8 table 3 minimum venting opening area for natural ventilation indoor unit 4 31 6
- Information 6
- Installation manual 6
- Multiple indoor units if two or more indoor units are installed in a room you must consider the maximum refrigerant charge that can be released in the room when a single leak occurs example if two indoor units are installed in the room each with its own outdoor unit then you have to consider the refrigerant charge of the largest indoor outdoor combination 6
- Preparation 6
- Systems with a total refrigerant charge 6
- Installation 7
- Opening the units 7
- Overview of electrical connections for external and internal actuators 7
- Preparing electrical wiring 7
- Preparing water piping 7
- To check the water volume and flow rate 7
- To open the indoor unit 7
- Installation 8
- To lower the switch box on the indoor unit 8
- Connecting refrigerant piping 9
- Installation 9
- Mounting the indoor unit 9
- To connect the drain hose to the drain 9
- To connect the refrigerant piping to the indoor unit 9
- To install the indoor unit 9
- Connecting water piping 10
- Installation 10
- To connect the water piping 10
- To connect the water piping for domestic hot water 10
- Installation 11
- To connect the recirculation piping 11
- About electrical compliance 12
- Connecting the electrical wiring 12
- Installation 12
- To connect the electrical wiring to the indoor unit 12
- To fill the domestic hot water tank 12
- To fill the water circuit 12
- To insulate the water piping 12
- Installation 13
- To connect the backup heater power supply 13
- To connect the main power supply 13
- 6v 6t1 3 230 v 14
- 6v 6v 1n 230 v 14
- A factory mounted cable connected to the contactor of the backup heater inside the switch box k1m for 3v models k5m for 6v and 9w models 14
- B field wiring see table below 14
- Connect the domestic hot water pump cable to the appropriate terminals as shown in the illustration below 14
- Connect the electricity meters cable to the appropriate terminals as shown in the illustration below 14
- Connect the valve control cable to the appropriate terminals as shown in the illustration below 14
- Connections to backup heater power 14
- Daikin altherma 3 r f 4p619456 1 2020 3 14
- Do not cut or remove the backup heater power supply cable 14
- Ehvh04 08su18 23da6v7 14
- F1b overcurrent fuse field supply recommended fuse 14
- Fix the cable with cable ties to the cable tie mountings 14
- In case of an electricity meter with transistor output check the polarity the positive polarity must be connected to x5m 6 and x5m 4 the negative polarity to x5m 5 and x5m 3 14
- Information 14
- Installation 14
- Installation manual 14
- K5m safety contactor in the lower switch box 14
- L1 l2 l3 14
- Model power 14
- Notice 14
- Pole 20 a curve 400 v tripping class c 14
- Q1di earth leakage circuit breaker field supply 14
- Shut off valve usage example in case of one lwt zone and a combination of underfloor heating and heat pump convectors install a shut off valve before the underfloor heating to prevent condensation on the floor during cooling operation for more information see the installer reference guide 14
- Supply 14
- Swb switch box 14
- To connect the domestic hot water pump 14
- To connect the electricity meters 14
- To connect the shut off valve 14
- Wiring is different for a nc normally closed valve and a no normally open valve 14
- X6m terminal field supply 14
- Installation 15
- To connect the alarm output 15
- To connect the changeover to external heat source 15
- To connect the power consumption digital inputs 15
- To connect the safety thermostat normally closed contact 15
- To connect the space cooling heating on off output 15
- Configuration 16
- Finishing the indoor unit installation 16
- Overview configuration 16
- To access the most used commands 16
- To close the indoor unit 16
- Configuration 17
- Configuration wizard 17
- Configuration wizard language 17
- Configuration wizard system 17
- Configuration wizard time and date 17
- Configuration 18
- Configuration wizard backup heater 18
- Configuration 19
- Configuration wizard main zone 19
- Configuration 20
- Configuration wizard additional zone 20
- Detailed screen with weather dependent curve 20
- Configuration 21
- Configuration wizard tank 21
- Additional zone 22
- Configuration 22
- Information 22
- Main zone 22
- Settings menu 22
- Configuration 23
- Depending on the selected installer settings and unit type settings will be visible invisible 23
- Ehvh04 08su18 23da6v7 daikin altherma 3 r f 4p619456 1 2020 3 23
- Information 23
- Installation manual 23
- Menu structure overview installer settings 23
- Solar kit settings are shown but are not applicable for this unit settings shall not be used or changed 23
- Checklist before commissioning 24
- Checklist during commissioning 24
- Commissioning 24
- To check the minimum flow rate 24
- To perform an air purge 24
- Hand over to the user 25
- Possible actuator test runs 25
- To perform an actuator test run 25
- To perform an operation test run 25
- To perform an underfloor heating screed dryout 25
- Hand over to the user 26
- A subset of the latest technical data is available on the regional daikin website publicly accessible the full set of latest technical data is available on the daikin business portal authentication required 27
- D111411 27
- Piping diagram indoor unit 27
- Technical data 27
- Technical data 28
- Wiring diagram indoor unit 28
- Technical data 29
- D128739 30
- Daikin altherma 3 r f 4p619456 1 2020 3 30
- Ehvh04 08su18 23da6v7 30
- Electrical connection diagram for more details please check the unit wiring 30
- Field supply 30
- Installation manual 30
- Outdoor unit 30
- Power supply 30
- Standard part 30
- Technical data 30
- Table 1 maximum refrigerant charge allowed in a room indoor unit 31
- Table 2 minimum floor area indoor unit 31
- Table 3 minimum venting opening area for natural ventilation indoor unit 31
- Technical data 31
- Technical specifications domestic hot water tank 31
- Test results in accordance with en12897 2016 31
- En12897 2016 32
- Technical data 32
- Technical specifications 32
- Warning label 32
- Warning to installer 32
- Warning to user 32
Похожие устройства
- Daikin EHVH08SU18DA6V7 Руководство по применению для установщика
- HP LaserJet Ultra MFP M230-M231 Инструкция по эксплуатации
- Армед CH211-130 Инструкция по эксплуатации
- Tecnoclima NTN/V 030 Инструкция по эксплуатации
- Tecnoclima NTN/V 030 Сертификат
- Tecnoclima NTN/V 030 Каталог
- Tecnoclima NTN/V 053 Инструкция по эксплуатации
- Tecnoclima NTN/V 053 Сертификат
- Tecnoclima NTN/V 053 Каталог
- Tecnoclima NTN/V 072 Инструкция по эксплуатации
- Tecnoclima NTN/V 072 Сертификат
- Tecnoclima NTN/V 072 Каталог
- Tecnoclima NTN/V 095 Инструкция по эксплуатации
- Tecnoclima NTN/V 095 Сертификат
- Tecnoclima NTN/V 095 Каталог
- Tecnoclima NTN/V 130 Инструкция по эксплуатации
- Tecnoclima NTN/V 130 Сертификат
- Tecnoclima NTN/V 130 Каталог
- Tecnoclima NTN/V 175 Инструкция по эксплуатации
- Tecnoclima NTN/V 175 Сертификат