Daikin EKCBH008BAV3 [16/20] Field settings table

Daikin EKCBH008BAV3 [16/20] Field settings table
Operation manual
15
EBHQ006+008BAV3 + EKCBX/H008BAV3
Unit for air to water heat pump system
4PW64603-1A – 08.2010
Field settings table
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range Step UnitDate Value Date Value
0 User permission level
00 User permission level 3 2/3 1
1 Weather dependent set point
00 Low ambient temperature (Lo_A) –10 –20~5 1 °C
01 High ambient temperature (Hi_A) 15 10~20 1 °C
02 Set point at low ambient temperature (Lo_Ti) 40 25~55 1 °C
03 Set point at high ambient temperature (Hi_Ti) 25 25~55 1 °C
2 Disinfection function
00 Operation interval
Fri
Mon~Sun,
All
——
01 Status 1 (ON) 0/1
02 Start time 23:00 0:00~23:00 1:00 hour
03 Set point 70 40~80 5 °C
04 Interval 10 5~60 5 min
3 Auto restart
00 Status 0 (ON) 0/1
4 Space heating off temperature
00 Installation related setting
01 Installation related setting
02 Space heating off temperature 25 14~25 1 °C
03 Installation related setting
04 Installation related setting
5 Installation related settings
00 Installation related setting
01 Installation related setting
02 Installation related setting
03 Installation related setting
04 Installation related setting
6 Installation related settings
00 Installation related setting
01 Installation related setting
02 Installation related setting
7 Installation related settings
00 Installation related setting
01 Installation related setting
02 Installation related setting
03 Installation related setting
04 Installation related setting
8 Installation related settings
00 Installation related setting
01 Installation related setting
02 Installation related setting
03 Installation related setting
04 Installation related setting