Daikin EKMBUHBA6V3 [6/12] Safety devices
![Daikin EKMBUHBA6V3 [6/12] Safety devices](/views2/1788335/page6/bg6.png)
Installation and operation manual
4
EKMBUHBA6V3
Heater kit for air to water heat pump system
4PW63549-1A – 08.2010
5.2. Safety devices
■ Thermal protector — The heater in the heater kit is equipped
with a thermal protector. The thermal protector is activated when
the temperature becomes too high. When activated, the
protector has to be reset on the heater of the heater kit by
pressing the red button (for access, remove the cover of the kit).
■ Pressure relief valve — In case valves are installed between the
outdoor unit and the heater kit and between the outlet and the
load, a pressure relief valve (field supply) in accordance with
relevant local laws and regulations, and with an opening
pressure of maximum 4 bar must be installed on the water inlet
of the heater kit.
6. INSTALLATION OF THE HEATER KIT
6.1. Selecting an installation location
The heater kit is to be wall mounted in an indoor location that meets
the following requirements:
■ The installation location is frost-free.
■ The space around the heater kit is adequate for servicing. (See
figure 3).
■ The space around the heater kit allows for sufficient air
circulation.
■ The installation surface is a flat and vertical non-combustible
wall, capable of supporting the operation weight of the heater kit.
■ There is no danger of fire due to leakage of inflammable gas.
■ All piping lengths and distances have been taken into
consideration.
■ During normal operation the heater kit will produce sound which
could be observed as noise. The sound origin can be contactor
activation. Therefore it is advisable to install the heater kit on a
firm wall and not in nor close to a sound sensitive environment
(e.g. bedroom).
■ Do not install the heater kit in places with high humidity (e.g.
bathroom).
■ The equipment is not intended for use in a potentially explosive
atmosphere.
■ Do not install the heater kit in places often used as work place.
In case of construction works (e.g. grinding works) where a lot of
dust is created, the heater kit must be covered.
■ Take care that in the event of a water leak, water can not cause
any damage to the installation space and surroundings.
■ Do not place any objects or equipment on top of the heater kit.
■ Make sure that there are no external magnetic fields in the
immediate vicinity of the flow switch, since these can impair
device functioning.
6.2. Dimensions and service space
Unit of measurement: mm.
Dimensions of the heater kit, see figure 2.
Required service space, see figure 3.
CAUTION
The heater kit air purge connection may not be used for
other purposes.
CAUTION
■ The electrical box lid must only be opened by a
licensed electrician.
■ Switch off the power supply before opening the
electrical box lid.
CAUTION
■ The heater kit can only be installed and used in
combination with the EBHQ outdoor unit and EKCB
indoor unit.
■ The heater of the heater kit can only be connected to
the space heating water outlet of the EBHQ outdoor
unit. Other connections are not allowed.
■ Only one heater kit can be connected to the EBHQ
outdoor unit. It is not allowed to combine multiple
heater kits in series or parallel.
Requirement Value
Maximum allowable distance between the heater kit
and the outdoor unit.
10 m
Содержание
- Definitions 3
- Efinitions 3
- Installation and operation manual 3
- Meaning of used terms 3
- Meaning of warnings and symbols 3
- Eneral safety precautions 4
- General safety precautions 4
- Accessories 5
- Accessories supplied with the heater kit 5
- Ccessories 5
- General information 5
- General system setup 5
- Introduction 5
- Main components 5
- Model identification 5
- Ntroduction 5
- Overview of the heater kit 5
- Scope of this manual 5
- Verview of the heater kit 5
- Dimensions and service space 6
- Installation of the heater kit 6
- Nstallation of the heater kit 6
- Safety devices 6
- Selecting an installation location 6
- Connecting the water circuits 7
- Field wiring 7
- Installing the heater kit 7
- 0 9 ω 8
- At the interface point between the user s supply and the public system it is the responsibility of the installer or user of the equipment to ensure by consultation with the distribution network operator if necessary that the equipment is connected only to a supply with a system impedance 8
- Cable requirements 8
- Caution 8
- Connections to be made in the heater kit 8
- Equipment complying with en iec 61000 3 1 8
- Internal wiring parts table 8
- Is less than or equal to 8
- Less than or equal to 8
- Notice 8
- Power supply using the appropriate cable connect the power supply cable to the appropriate terminals 8
- Procedure 8
- Provided that the system impedance 8
- Refer to the chapter field wiring of the ekcb indoor unit installation manual for details where to use high voltage hv and low voltage lv cables 8
- Refer to the internal wiring diagram supplied with the heater kit on the inside of the heater kit the abbreviations used are listed below 8
- Refer to the wiring diagram sticker on the inside of the heater kit front panel 8
- Select all cables and wire sizes in accordance with relevant local and national regulations 8
- The electrical connection diagram can be found on the inside of the switch box cover 8
- The heater kit needs to be connected to a normal power supply connecting the heater kit to a benefit kwh rate power supply is only allowed in case the power supply is not shut off when benefit kwh rate is active for details on benefit kwh rate power supplies refer to the outdoor unit installation manual 8
- This equipment complies with en iec 61000 3 1 8
- Use a dedicated power circuit for the heater kit never use a power circuit shared by another appliance 8
- Pre operation checks 9
- Start up and configuration 9
- Up and configuration 9
- Aintenance and service 10
- Final check 10
- Final check and test run 10
- Inal check and test run 10
- Maintenance and service 10
- Normal operation 10
- Operating instructions 10
- Perating instructions 10
- Test run 10
- Disposal requirements 11
- Echnical specifications 11
- Error codes 11
- General guidelines 11
- General symptoms 11
- Isposal requirements 11
- Roubleshooting 11
- Technical specifications 11
- Troubleshooting 11
Похожие устройства
- Daikin EBHQ006BBV3 Инструкция по эксплуатации
- Daikin EBHQ006BBV3 Приложение к руководству для дополнительного оборудования
- Daikin EBHQ006BBV3 Инструкция по монтажу
- Daikin EBHQ008BBV3 Инструкция по эксплуатации
- Daikin EBHQ008BBV3 Приложение к руководству для дополнительного оборудования
- Daikin EBHQ008BBV3 Инструкция по монтажу
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Инструкция по эксплуатации
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Сертификат
- Foodatlas Постмикс LEF-3\5 Foodatlas Eco Инструкция по эксплуатации
- Foodatlas Постмикс LEF-3\5 Foodatlas Eco Сертификат
- Foodatlas H001 Инструкция по эксплуатации
- Foodatlas H001 Сертификат
- Foodatlas PS-1 Инструкция по эксплуатации
- Foodatlas PS-1 Сертификат
- Foodatlas SM-1388 Инструкция по эксплуатации
- Foodatlas SM-1388 Сертификат
- Daikin EBLQ05C2V3 Руководство по монтажу
- Daikin EBLQ05C2V3 Общие правила техники безопасности
- Daikin EBLQ05C2V3 Руководство по применению для установщика
- Daikin EBLQ07C2V3 Руководство по монтажу