3 Operation
3.1 General
3.2 Display and operating elements
3.2.1 Display
All operating steps are supported by corresponding displays on a
coloured backlit plain text display.
The menu guidance can be displayed 7 languages (see
chap.
3.4.8).
The colour of the backlighting indicates the operational status
and the operating mode:
DANGER!
If electrical components come into contact with
water, this can cause an electric shock as well
as cause potentially fatal burns or injuries.
The displays and the keys of the control unit
must be protected against the effects of
moisture.
To clean the control unit, use a dry cotton
cloth. Using aggressive cleaning agents
and other fluids can cause damage to
devices or lead to an electric shock.
Maximum energy exploitation
The ROTEX HPSU monobloc compact makes the
most effective use of energy at the lowest possible
return and target hot water temperature.
If an external heat generator (e.g. the optional backup heater)
is activated at target feed temperatures over 50
°C, the effi-
ciency (COP) of the ROTEX HPSU monobloc compact can de-
teriorate (depending on the outside temperature).
1 Clear text display
2 Setting: Configuration
3 Setting: Remote Param
4 Rotary switch
5 Setting: Info
6 Setting: Operating Mode
7 Setting: Set Temp Day
8 Setting: Set Temp Night
9 Setting: DHW Set Temp
10 Rotary button
11 Setting: DHW Install
12 Setting: Time Program
13 Exit key
Fig. 3-1 Arrangement of display and operating elements
Malfunctions are generally indicated by a fault code and
a clear text fault message on the display.
For troubleshooting instructions, see Chapter 7.
White: Standard lighting, normal operating display.
Red: Fault status; depending on the type of fault, the
ROTEX HPSU monobloc compact continues to
operate with restrictions.
Green: Operating mode with operator authorisation.
Blue: Operating mode with expert authorisation.
1 Display date
2 Refrigerant compressor
status
3 Status display (e.g. techni-
cian access rights active)
4 Display time
5 Current feed temperature
6 Heating circuit status
7 Current outside temperature
8 Active operating mode
9 Hot water generation status
10 Current storage temperature
Fig. 3-2 Display of the control unit - standard display