Daikin ERLQ007BBV39 [3/20] Definitions
![Daikin ERLQ007BBV39 [3/20] Definitions](/views2/1788905/page3/bg3.png)
ERLQ006~008BBV39
Outdoor unit for air to water heat pump
4PW68003-1A – 03.2011
Installation manual
1
CONTENTS Page
1. Definitions ..................................................................................1
1.1. Meaning of warnings and symbols................................................. 1
1.2. Meaning of used terms................................................................... 2
2. General safety precautions ........................................................2
Warning.......................................................................................... 3
Caution........................................................................................... 3
3. Before installation ......................................................................4
3.1. Scope of the manual ...................................................................... 4
3.2. Precautions for R410A ................................................................... 4
3.3. Installation ...................................................................................... 4
3.4. Model identification......................................................................... 4
3.5. Accessories.................................................................................... 4
3.6. Handling ......................................................................................... 4
4. Overview of unit .........................................................................5
4.1. Opening the unit............................................................................. 5
4.2. Main components........................................................................... 5
4.3. Functional diagram......................................................................... 5
5. Selecting installation site............................................................5
5.1. General........................................................................................... 5
5.2. Selecting a location in cold climates............................................... 6
6. Precautions on installation.........................................................7
6.1. foundation work .............................................................................. 7
6.2. Drain work ...................................................................................... 7
General........................................................................................... 7
7. Installation servicing space........................................................7
Wall facing one side (unit: mm) ...................................................... 7
Walls facing two sides (unit: mm) ................................................... 7
Walls facing three sides (unit: mm)................................................. 7
7.1. Outdoor unit installation drawing.................................................... 7
8. Refrigerant pipe size and allowable pipe length.........................8
8.1. Selection of piping material ............................................................ 8
8.2. Refrigerant pipe size ...................................................................... 8
8.3. Allowable pipe length and height difference................................... 8
9. Precautions on refrigerant piping...............................................8
10. Refrigerant piping.......................................................................9
10.1. Flaring the pipe end ....................................................................... 9
10.2. Connecting the refrigerant piping to the outdoor unit ..................... 9
10.3. Refrigerant piping work .................................................................. 9
Pipe handling guidelines ................................................................ 9
Selection of copper and heat insulation materials.......................... 9
11. Leak test and vacuum drying...................................................10
11.1. General guidelines ....................................................................... 10
12. Charging refrigerant.................................................................11
12.1. Important information regarding the refrigerant used................... 11
12.2. Precautions and general guidelines ............................................. 11
12.3. Calculating the additional refrigerant............................................ 11
12.4. Complete recharging.................................................................... 11
13. Pump down operation..............................................................12
13.1. Pump down procedure ................................................................. 12
13.2. Forced cooling operation.............................................................. 12
14. Electrical wiring work ...............................................................12
14.1. Precautions on electrical wiring work ........................................... 12
14.2. Internal wiring – Parts table.......................................................... 13
14.3. Connecting power supply and interunit wiring.............................. 13
Notes to observe .......................................................................... 14
14.4. Electrical characteristics............................................................... 14
15. Test operation ..........................................................................14
15.1. Pre-run checks ............................................................................. 14
15.2. Trial operation and testing ............................................................ 15
16. Maintenance and servicing ......................................................15
16.1. Service precautions...................................................................... 15
16.2. Service mode operation ............................................................... 15
17. Disposal requirements .............................................................15
18. Unit specifications....................................................................15
18.1. Technical specifications................................................................ 15
18.2. Electrical specifications ................................................................ 15
Thank you for purchasing this product.
The original instructions are written in English. All other languages
are translations of the original instructions.
1. DEFINITIONS
1.1. Meaning of warnings and symbols
Warnings in this manual are classified according to their severity and
probability of occurrence.
Some types of danger are represented by special symbols:
ERLQ006BBV39
ERLQ007BBV39
ERLQ008BBV39
Outdoor unit for air to water heat pump
Installation manual
CAREFULLY READ THESE INSTRUCTIONS BEFORE
INSTALLATION. THEY WILL TELL YOU HOW TO INSTALL
AND HOW TO CONFIGURE THE UNIT PROPERLY.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE
REFERENCE.
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also
be used to alert against unsafe practices.
NOTICE
Indicates situations that may result in equipment or
property-damage accidents only.
INFORMATION
This symbol identifies useful tips or additional information.
Electric current.
Danger of burning and scalding.
Содержание
- Installation manual 1
- Outdoor unit for air to water heat pump 1
- Daikin europe n v 2
- En60335 2 40 2
- Erlq006bbv39 erlq007bbv39 erlq008bbv39 2
- Jean pierre beuselinck general manager ostend 1st of april 2011 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 ec 2
- Pw68004 2 2
- Definitions 3
- Efinitions 3
- Installation manual 3
- Meaning of warnings and symbols 3
- Eneral safety precautions 4
- General safety precautions 4
- Meaning of used terms 4
- Caution 5
- Warning 5
- Accessories 6
- Before installation 6
- Efore installation 6
- Handling 6
- Installation 6
- Model identification 6
- Model identification 6
- Precautions for r410a 6
- Scope of the manual 6
- Electing installation site 7
- Functional diagram 7
- General 7
- Main components 7
- Opening the unit 7
- Overview of unit 7
- Selecting installation site 7
- Verview of unit 7
- Selecting a location in cold climates 8
- Drain work 9
- Foundation work 9
- General 9
- Installation servicing space 9
- Nstallation servicing space 9
- Outdoor unit installation drawing 9
- Precautions on installation 9
- Recautions on installation 9
- Wall facing one side unit mm 9
- Walls facing three sides unit mm 9
- Walls facing two sides unit mm 9
- Allowable pipe length and height difference 10
- Efrigerant pipe size and allowable pipe length 10
- Precautions on refrigerant piping 10
- Recautions on refrigerant piping 10
- Refrigerant pipe size 10
- Refrigerant pipe size and allowable pipe length 10
- Selection of piping material 10
- Connecting the refrigerant piping to the outdoor unit 11
- Efrigerant piping 11
- Flaring the pipe end 11
- Pipe handling guidelines 11
- Refrigerant piping 11
- Refrigerant piping work 11
- Selection of copper and heat insulation materials 11
- Eak test and vacuum drying 12
- General guidelines 12
- Leak test and vacuum drying 12
- Calculating the additional refrigerant 13
- Charging refrigerant 13
- Complete recharging 13
- Harging refrigerant 13
- Important information regarding the refrigerant used 13
- Precautions and general guidelines 13
- Electrical wiring work 14
- Forced cooling operation 14
- Lectrical wiring work 14
- Precautions on electrical wiring work 14
- Pump down operation 14
- Pump down procedure 14
- Ump down operation 14
- Connecting power supply and interunit wiring 15
- Internal wiring parts table 15
- Electrical characteristics 16
- Est operation 16
- Notes to observe 16
- Pre run checks 16
- Test operation 16
- Aintenance and servicing 17
- Disposal requirements 17
- Electrical specifications 17
- Electrical specifications 17
- Isposal requirements 17
- Maintenance and servicing 17
- Nit specifications 17
- Service mode operation 17
- Service precautions 17
- Technical specifications 17
- Technical specifications 17
- Trial operation and testing 17
- Unit specifications 17
Похожие устройства
- Daikin ERLQ008BBV39 Инструкция по монтажу
- Daikin ERHQ006BBV3 Инструкция по монтажу
- Daikin ERHQ007BBV3 Инструкция по монтажу
- Daikin ERHQ008BBV3 Инструкция по монтажу
- Daikin ERLQ006BBV3 Инструкция по монтажу
- Daikin ERLQ007BBV3 Инструкция по монтажу
- Daikin ERLQ008BBV3 Инструкция по монтажу
- TOTAL TTAC2506 Инструкция по эксплуатации
- TOTAL TG111136 Инструкция по эксплуатации
- TOTAL THKTHP1012 Инструкция по эксплуатации
- TOTAL TG106136 Инструкция по эксплуатации
- TOTAL TG109136 Инструкция по эксплуатации
- TOTAL TS1141856 Инструкция по эксплуатации
- TOTAL TS1222356 Инструкция по эксплуатации
- TOTAL TS1161856 Инструкция по эксплуатации
- TOTAL TF2041501 Инструкция по эксплуатации
- TOTAL TS100802 Инструкция по эксплуатации
- Gigaset AS405 Инструкция по эксплуатации
- TOTAL TS100806 Инструкция по эксплуатации
- Gigaset AS405A Инструкция по эксплуатации