Daikin AZQS140A7V1B [4/31] Specifications

Daikin AZQS140A7V1B [4/31] Specifications
3
1
2
Siesta® • Outdoor Unit
3
Outdoor Unit • Pair application • AZQS-AV1
2 Specifications
Notes
(1) Energy label: scale from A (most efficient) to G (less efficient)
(2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
(3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB; equivalent piping length: 5m (horizontal)
(4) Nominal heating capacities are based on: indoor temperature: 20ºCDB, outdoor temperature: 7ºCDB, 6ºCWB, equivalent refrigerant piping: 5m, level difference: 0m.
Notes
(1) Energy label: scale from A (most efficient) to G (less efficient)
(2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
(3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB; equivalent piping length: 5m (horizontal)
(4) Nominal heating capacities are based on: indoor temperature: 20ºCDB, outdoor temperature: 7ºCDB, 6ºCWB, equivalent refrigerant piping: 5m, level difference: 0m.
Notes
(1) Energy label: scale from A (most efficient) to G (less efficient)
(2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
(3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB; equivalent piping length: 5m (horizontal)
(4) Nominal heating capacities are based on: indoor temperature: 20ºCDB, outdoor temperature: 7ºCDB, 6ºCWB, equivalent refrigerant piping: 5m, level difference: 0m.
2-1 Nominal Capacity And Nominal Input
ABQ71AV1 /
AZQS71A2V1B
ABQ100AV1 /
AZQS100A7V1B
ABQ125AV1 /
AZQS125A7V1B
ABQ140AV1 /
AZQS140A7V1B
Cooling capacity
Nom. kW 7.2 (3) 10.2 (3) 13.3 (3) 13.9 (3)
Heating capacity
Nom. kW 8.3 (4) 11.2 (4) 15.9 (4) 16.5 (4)
Power input Cooling Nom. kW 2.21 3.09 4.15 4.61
Heating Nom. kW 2.21 3.03 4.40 4.83
EER 3.26 3.30 3.21 3.01
COP 3.75 3.71 3.62 3.41
Annual energy consumption kWh 1,105 1,545 2,075 2,305
Energy label Cooling AB
Heating AB
2-1 Nominal Capacity And Nominal Input ACQ71AV1 / AZQS71A2V1B ACQ100AV1 / AZQS100A7V1B ACQ125AV1 / AZQS125A7V1B
Cooling capacity
Nom. kW 7.4 (3) 10.2 (3) 13.0 (3)
Heating capacity
Nom. kW 8.3 (4) 11.9 (4) 14.1 (4)
Power input Cooling Nom. kW 2.24 3.18 4.03
Heating Nom. kW 2.30 3.30 3.91
EER 3.31 3.21 3.23
COP 3.61
Annual energy consumption kWh 1,120 1,590 2,015
Energy label Cooling A
Heating A
2-1 Nominal Capacity And Nominal Input
AHQ71AV1 /
AZQS71A2V1B
AHQ100AV1 /
AZQS100A7V1B
AHQ125AV1 /
AZQS125A7V1B
AHQ140AV1 /
AZQS140A7V1B
Cooling capacity
Nom. kW 7.6 (3) 9.7 (3) 12.6 (3) 13.5 (3)
Heating capacity
Nom. kW 8.1 (4) 11.4 (4) 15.4 (4) 16.6 (4)
Power input Cooling Nom. kW 2.51 3.20 4.44 5.13
Heating Nom. kW 2.66 3.51 4.80 4.37
EER 3.03 2.84 2.63
COP 3.05 3.25 3.21 3.80
Annual energy consumption kWh 1,255 1,600 2,220 2,565
Energy label Cooling B C D
Heating D C A
2-2 Technical Specifications AZQS71AV1 AZQS100AV1 AZQS125AV1 AZQS140AV1
Capacity control
Method Inverter controlled
Casing Colour Ivory white
Material Painted galvanized steel plate