Comet MTP AXR 9/140 TSI [29/80] Routine maintenance

Comet MTP RW 15/230 TSR [29/80] Routine maintenance
29
NOTE:
Aeraprolongedstop,slightwaterdrippingcouldoccurunderneaththepump.Suchdrippingnormally
disappearsaerafewhoursofoperation.Shoulditpersist,contactaSkilled Technician.
mAINTENANCE
WARNING
•Followthemaintenanceinstructionscontainedinthemanualofthemachineinwhichthepumpis
integrated.
•Allmaintenancejobsmustonlybe performedaer carryingout theoperationsdescribedinthe
“stop
paragraph,meaningwithoutanymovingparts,nopipefullofliquidunderpressureandonlyaercomplete
cooling.
Inparticular,alwaysremembertodisconnectthepowersupply.
•Anymaintenancejobsmustbeperformedinconditionsoftotalstability.
•WARNING.Toensurethesafetyofthepump,onlyuseoriginalsparepartssuppliedbytheManufactureror
approvedbyit.
ROUTINE mAINTENANCE
Perform the routine maintenance jobs shown in the manual of the machine in which the pump is integrated;
unless otherwise indicated, in relation to the pump, remember the following.
mAINTENANCE SCHEDULE JOb
After every use •Checkoil levelandconditionsaccordingtoinstructionsin
“PRELIMINARY
ACTIvITIES
paragraph.
Every 50 hours •Checktheintegrityofthesuctioncircuit.
•Checkandifnecessarycleanthesuctionlter.
•Checkthefasteningofthepumptothemotortowhichitiscoupledand/or
to the structure of the machine in which it is integrated.
In the event of such fastening being precarious, do not use the machine and
contact a Skilled Technician
(1)
.
(1)
Checks must be made more frequently if the pump operates where there are strong vibrations.
SPECIAL mAINTENANCE
WARNING
•SpecialmaintenancejobsmustonlybeperformedbyaSkilled Technician.
•Usedoilmustbeadequatelydisposedofandnotdiscardedintheenvironment.
Perform the routine maintenance jobs shown in the manual of the machine in which the pump is integrated;
unless otherwise indicated, in relation to the pump, remember the following.
mAINTENANCE SCHEDULE JOb
Every 500 hours (200 hours for series AX
and BX).
•Checkthesuction/deliveryvalves.
•Checkthetightnessofthepumpscrews
(*)
.
•Oilchange
(**)
.
•Checkthepressureunloader/regulationvalve.
(*)
Checks should be made more frequently if the pump operates where there are strong vibrations.
(**)
The rst oil change is best made after 50 hours.
CAUTION
•edatashownonthechartareapproximate.Morefrequentjobsmaybenecessaryincaseofparticularly
heavy-dutyuse.