Comet MTP LW 1/70 (220 В) [27/104] Specifications and technical data

Comet MTP LW 1/70 (220 В) [27/104] Specifications and technical data
27
e manual must be deemed an integral part of the motor pump and must be looked aer for future reference
and kept in a protected place where it can easily be referred to in case of need.
e manual contains safety precautions for the operator and those surrounding him/her and for the protection
of the environment.
In case of deterioration or loss, a new copy must be requested from the Manufacturer or from a
Skilled
Technician
.
In the event of the machine in which the motor pump is integrated being transferred to another user, please
include also this manual.
e Manufacturer reserves the right to make all the amendments required to update and correct this publication
without prior notice.
SYMBOLS
e symbol:
WARNING
marking certain parts of the text indicates a likely chance of injury to persons unless the relative prescriptions
and indications are followed.
e symbol:
CAUTION
marking certain parts of the text indicates the possibility of damaging the motor pump unless the relative
instructions are followed.
SPECIFICATIONS AND TECHNICAL DATA
e motor pumps consist of a piston pump, including a pressure limiting/unloader valve (also see
“SAFETY
DEvICES
paragraph), coupled to an electric motor (single phase if the plate shows theMNF code; three phase if
the plate shows theTRF code). Versions are also available featuring electric box, power cable, ON/OFF switch
and Total-Stop device.
POWER CONNECTION
Power voltage, frequency and power are shown on
the plate(12).
PUMP OIL
MTP TW 500 GAZPROMNEFT SUPER OIL GTD 15-W40
(*)
Other motor pumps ENI MULTITECH THT
(**)
HYDRAULIC CONNECTION
Max water supply temperature
MTPKTR- MTPKTRMisting- MTPKMR- MTPKSR -
MTPKSRMisting
50 °C - 122 °F
Other motor pumps 60 °C - 140 °F
Min water supply temperature 5 °C - 41 °F
Max water supply pressure 0,8 MPa - 8 bar - 116 psi
Min water supply ow rate 1.3 x max motor pump ow rate
Max priming depth
MTP KTR - MTP KTR Misting - MTP KMR - MTP KSR - MTP KSR
Misting- MTP AX Misting- MTP LW Misting
0 m - 0 ft
MTP LWR-K 250 - MTP LWR-K - MTP ZWR-K - MTP AXR 0,5 m - 1,7 ft
Other motor pumps 1,0 m - 3,3 ft
(continued on next page)