Comet MTP LW 1/70 (220 В) [31/104] Checking and connecting up to water mains

Comet MTP FW2 18/70 [31/104] Checking and connecting up to water mains
31
CAUTION
In case of operation at very low temperatures, make sure there is no ice inside the pump and pipes.
Perform the checks required by routine maintenance, with special reference to those relating to the oil.
CHECKING AND CONNECTING UP TO THE POWER SUPPLY
WARNING
Also follow the instructions contained in the manual of the machine in which the motor pump is
integrated.
• A
Skilled Technician
must:
- make sure the power supply of the motor pump features a suitable fuse and is in conformity with the details
shown on the plate (12): in particular, the power voltage must not be outside the ±5% range;
- connect a plug in compliance with the laws applicable in the country where the machine in which the motor
pump is integrated is installed, in the case of the power lead being without such plug and of the motor pump
not being permanently connected to a power supply source.
e connection to the power source must be made by a
Skilled Technician
and must be in compliance with
the requirements of IEC60364-1.
e power supply line of the motor pump must be tted with a switch able to interrupt the power supply
whenever ground dispersion exceeds 30mA for 30ms or with a device for testing the earth circuit.
If the motor pump does not have a power lead and plug, or another device for disconnecting it from the mains,
with a contact opening distance that allows complete disconnection in overvoltage III category conditions, such
disconnection devices must be tted to the supply mains in compliance with installation regulations.
Note:
in this use and maintenance manual, for the sake of simplicity, the motor pump shall always be deemed
connected to the power mains by means of a plug.
If the motor pump is permanently connected to the power supply, this means:
- the mains disconnection device in o (“0”) position is equivalent to removing the plug from the power socket;
- the mains disconnection device in on (“1”) position is equivalent to tting the plug in the power socket.
In the event of the power cable being too short, an extension can be used as long as this does not exceed
10m/32,8, and that the cross section of the leads is at least 1.5mm
2
(motor pumps with inputs below 13A),
or 2.5mm
2
.
WARNING
. If an extension is used, the plug and the socket must be of the sealed-immersion type.
WARNING
. Inadequate extensions can be dangerous.
Do not use reductions or adapters between power plug and socket.
CHECKING AND CONNECTING UP TO WATER MAINS
WARNING
Also follow the instructions contained in the manual of the machine in which the motor pump is
integrated.
Follow the water mains connection instructions applicable in the country where the machine in which the motor
pump is integrated is installed.
CAUTION
Follow the water mains connection instructions shown in the
“SPECIFICATIONS AND TEChNICAL DATA
paragraph,
with special reference to the priming depth and supply pressure and temperature: in case of any doubts,
contact a
Skilled Technician.
e suction of motor pump must always be equipped with a suitably-sized lter: frequently make sure this
is clean.
Never operate the motor pump:
- without water supply;
- with salt water or water containing impurities: if this occurs, have it operate for a few minutes with clean
water.
EN