Daikin EKOMBG22AAV1 [51/56] Technical specifications

Daikin EKOMBG22AAV1 [51/56] Technical specifications
Daikin Europe NV
51
10 TECHNICAL SPECIFICATIONS
Unit category
C13; C 33; C43; C53; C63; C83: C93
Initial gas
pressure
G20
20 mbar; G31 : 30 mbar
II2H3+
EKOMBG*AAV1
22
28
33
Domestic water
Nom. load upper value
kW
6.1
25.9
8.0
32.3
8.3
36.3
Nom. load lower value
kW
5.
6
23.3
7.
1
29.1
7.
6
32.7
Nom.
out
put
kW
5.9
22.7
7.7
28.4
8.2
32.1
Domestic water threshold
l/min
2
Domestic water quantity 60°C
l/min
6
7.5
9
Domestic water quantity 40°C (mixed)
l/min
10
12.5
15
Domestic water temperature
°C
60
Effective unit wait time*
sec
<1
Domestic water side pressure difference
kPa
See par.
5.2
CH
Nom. load upper value**
kW
6.1
25.9
8.0
32.3
8.3
36.3
Nom. load lower
value**
kW
5.
6
23.3
7.
1
29.1
7.
6
32.7
Nom.
out
put
kW
5.9
22.7
7.7
28.4
8.2
32.1
Max. CH water pressure
bar
3
Max. CH water temperature
°C
90
Other data
Gas consumption (G25)
m
3
/h
0.67
2.80
0.85
3.50
0.91
3.93
Gas
consumption (G20)
m
3
/h
0.58
2.42
0.74
3.02
0.79
3.39
Gas consumption (G31)
m3/h
0.22
0.92
0.28
1.15
0.30
1.29
Pressure loss of the unit (CH)
mWk
See par.
7.4
Electrical data
Mains voltage
V
230
Safety class
IP
IP44
Absorbed power: full load
W
80
Absorbed power: part load
W
40
Absorbed power: standby
W
2
Installation
measurements and weight
Height
mm
590
650
710
Width
mm
450
Depth
mm
240
Weight
kg
30
33
36
* Time needed from beginning of draining in order to achieve a temperature increase of 40K to the hot water outlet of the
device based on the CW-hot water flow.
** Maximum CH power is set at the factory at 60% of the highest value (see par. 7.3 Setting CH power).

Содержание

Скачать