9 Automatic temperature compensation
00 Leaving water temperature compensation value
(heating)
0 –2~2 0.2 °C
01 Domestic hot water tank compensation value 0 –5~5 0.5 °C
02 Thermo ON/OFF admission 0 –5~5 0.5 °C
03 Not applicable. Do not change the default value. 0 — — —
04 Not applicable. Do not change the default value. 0 — — —
A Option setup
00 Current limitation. 0 0~2 1 —
01 Not applicable. Do not change the default value. 0 — — —
02 Set point: heating required temperature difference
for leaving and returning water
10 3~15 1 °C
03 Set point: multiple set point 1 required temperature
value
35 25~80 1 °C
04 Set point: multiple set point 2 required temperature
value
65 25~80 1 °C
b Domestic hot water set points
00 Set point: reheat minimum temperature 35 35~65 1 °C
01 Set point: reheat maximum temperature 45 35~75 1 °C
02 Status: weather dependent domestic water
heating
1 (ON) 0/1 — —
03 Set point: storage temperature 70 45~75 1 °C
04 Automatic maximum domestic hot water storage
temperature
70 55~75 1 °C
C Leaving water temperature limits
00 Set point: heating leaving water maximum
temperature
80 37~80 1 °C
01 Set point: heating leaving water minimum
temperature
25 25~37 1 °C
02 Not applicable. Do not change the default value. 20 — — —
03 Not applicable. Do not change the default value. 5 — — —
04 Not applicable. Do not change the default value. 0 — — —
d Domestic water heating retention times
00 Set point: minimum time for domestic water
heating
10 5~20 1 —
01 Set point: maximum time for domestic water
heating
30 10~60 5 —
02 Set point: interval minimum stop time of domestic
water heating
15 5~30 5 —
03 Not applicable. Do not change the default value. 15 — — —
04 Not applicable. Do not change the default value. 40 — — —
E Service mode
00 Vacuum mode R134a 0 0/1 — —
01 Not applicable. Do not change the default value. 0 — — —
02 Not applicable. Do not change the default value. 0 — — —
03 Not applicable. Do not change the default value. 1 — — —
04 Pump only operation 0 0~25 1 —
F Option setup continued
00 Not applicable. Do not change the default value. 5 — — —
01 Not applicable. Do not change the default value. 0 — — —
02 Not applicable. Do not change the default value. 1 — — —
03 Not applicable. Do not change the default value. 10 — — —
04 Not applicable. Do not change the default value. 50 — — —
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range Step UnitDate Value Date Value
Содержание
Похожие устройства
- Daikin EKHBRD016ADV1 Инструкция по монтажу
- Daikin EKHBRD016ADV1 Инструкция по эксплуатации
- Daikin EKHBRD011ADY1 Руководство по монтажу
- Daikin EKHBRD011ADY1 Инструкция по эксплуатации
- Daikin EKHBRD011ADY1 Инструкция по монтажу
- Daikin EKHBRD014ADY1 Руководство по монтажу
- Daikin EKHBRD014ADY1 Инструкция по эксплуатации
- Daikin EKHBRD014ADY1 Инструкция по монтажу
- Daikin EKHBRD016ADY1 Руководство по монтажу
- Daikin EKHBRD016ADY1 Инструкция по эксплуатации
- Daikin EKHBRD016ADY1 Инструкция по монтажу
- Apeyron Electrics 05-28 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-33 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-37 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-38 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-39 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-40 Инструкция по установке и эксплуатации
- Daikin EKHBRD011ADV17 Инструкция по эксплуатации
- Daikin EKHBRD011ADV17 Инструкция по монтажу
- Daikin EKHBRD014ADV17 Инструкция по эксплуатации