Daikin EKHBRD014ADY1 [5/24] Setting the clock
![Daikin EKHBRD011ADV1 [5/24] Setting the clock](/views2/1797293/page5/bg5.png)
EKHBRD011~016ADV1+Y1
Indoor unit for air to water heat pump system and options
4P402192-1A – 2015.04
Operation manual
4
24. DOMESTIC WATER HEATING BUTTON
This button enables or disables the different domestic hot water
modes in combination with the schedule timer button.
This button is not used when the domestic hot water tank is not
installed.
25. WEATHER DEPENDENT SET POINT BUTTON
This button enables or disables the weather dependent set point
function which is available in space heating operation.
If the controller is set to permission level 3 (refer to "Field
settings" in the installation manual), the weather dependent set
point button will not be operable.
26. INSPECTION/TEST OPERATION BUTTON
This button is used for installation purposes and changing field
settings. Refer to "Field settings" on page 16.
27. PROGRAMMING BUTTON
This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.
28. SCHEDULE TIMER BUTTON /
The main function of this multi-purpose button is to
enable/disable the schedule timer.
The button is also used to set the clock and to program the
controller. The function of the button depends on the actual
status of the controller or on previous actions carried out by the
operator.
29. TIME ADJUST BUTTONS and
These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (water inlet/outlet temperature of
the indoor unit, outdoor ambient temperature, actual room
temperature and domestic hot water temperature) and in
schedule timer programming mode.
30. LEAVING WATER TEMPERATURE ADJUST BUTTONS
and
These buttons are used to adjust the leaving water temperature
set point in normal operation mode or in schedule timer
programming mode.
If the controller is set to permission level 3 (refer to "Field
settings" in the installation manual), the leaving water
temperature adjust button will not be operable.
In case the weather dependent set point operation is selected,
the unit has a floating set point. In this case, the icon as well
as the shift value (in case not zero) will display.
31. ROOM TEMPERATURE ADJUST BUTTONS and
These multi-purpose buttons are used to adjust the current room
temperature set point in normal operation mode or in schedule
timer programming mode.
When changing the room temperature set point, the set point
value on the display will be flashing. After 5 seconds the display
will show to the actual room temperature.
32. QUIET MODE BUTTON
This button enables or disables quiet mode.
If the controller is set to permission level 2 or 3 (refer to "Field
settings" in the installation manual), the quiet mode button will
not be operable.
33. The
button has no function.
Setting the clock
After initial installation, the user can set the clock and day of the week.
The remote controller is equipped with a schedule timer that enables
the user to schedule operations. Setting the clock and day of the
week is required to be able to use the schedule timer.
1 Hold down the button for 5 seconds.
The clock read-out and the day of week indicator start flashing.
2 Use the and buttons to adjust the clock.
Each time the or button is pressed, the time will
increase/decrease by 1 minute. Keeping the or
button pressed will increase/decrease the time by 10 minutes.
3 Use the or button to adjust the day of the week.
Each time the or button is pressed the next or
previous day is displayed.
4 Press the button to confirm the current set time and day of the
week.
To leave this procedure without saving, press the button.
If no button is pressed for 5 minutes the clock and day of the
week will return to their previous setting.
NOTE
Remark that pushing the button has no
influence on the domestic water heating.
Domestic water heating is only switched on or off
by means of the button and/or disabling the
storage schedule timer.
NOTE
■ The clock needs to be set manually. Adjust the
setting when switching from summertime to
wintertime and vice versa.
■ If the controller is set to permission level 2 or 3
(refer to "Field settings" in the installation
manual), setting the clock will not be possible.
■ A power failure exceeding 1 hour will reset the
clock and the day of the week. The schedule timer
will continue operation, but with a disordered
clock. Therefor it will be needed to correct the
clock and the day of the week.
Содержание
- And options 1
- Indoor unit for air to water heat pump system 1
- Operation manual 1
- General information 2
- Introduction 2
- Operation manual 2
- Scope of this manual 2
- Domestic water heating operation 3
- Operation of the unit 3
- Peration 3
- Quick start up of the unit 3
- Space heating operation 3
- Remote controller buttons and icons 4
- Setting the clock 5
- Leaving water temperature control 6
- Room temperature control 6
- Space heating operation 6
- Space heating operation h 6
- Automatic storage 8
- Domestic water heating operation 8
- Domestic water heating operation w 8
- Manual storage 9
- Defrost operation 10
- Defrost operation d 10
- Disinfection operation 10
- Emergency operation 10
- Other operation modes 10
- Quiet mode operation 10
- Quiet mode operation s 10
- Reheat 10
- Start up operation 10
- Start up operation d 10
- Schedule timer operation 11
- Simultaneous demand of space heating and domestic water heating 11
- Space heating 11
- Temperature read out mode 11
- Off on on 12
- Operation example schedule timer based on on off instruction 12
- Operation example schedule timer based on temperature set points 12
- When setback function is enabled the setback operation will have priority over the scheduled action in the schedule timer 12
- When setback function is enabled the setback operation will have priority over the scheduled action in the schedule timer if on instruction is active if off instruction is active this will have priority over the setback function at any time the off instruction will have the highest priority 12
- Domestic water heating 13
- Programming and consulting the schedule timer 13
- Quiet mode 13
- Programming space heating 14
- Consulting programmed actions 15
- Programming quiet mode or domestic water heating 15
- Operating the optional remote controller 16
- Operating the remote alarm option 16
- Tips and tricks 16
- Field settings 17
- Procedure 17
- Field settings table 18
- Aintenance 20
- Disposal requirements 20
- Important information regarding the refrigerant used 20
- Isposal requirements 20
- Maintenance 20
- Maintenance activities 20
- Roubleshooting 20
- Troubleshooting 20
Похожие устройства
- Daikin EKHBRD014ADY1 Инструкция по монтажу
- Daikin EKHBRD016ADY1 Руководство по монтажу
- Daikin EKHBRD016ADY1 Инструкция по эксплуатации
- Daikin EKHBRD016ADY1 Инструкция по монтажу
- Apeyron Electrics 05-28 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-33 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-37 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-38 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-39 Инструкция по установке и эксплуатации
- Apeyron Electrics 05-40 Инструкция по установке и эксплуатации
- Daikin EKHBRD011ADV17 Инструкция по эксплуатации
- Daikin EKHBRD011ADV17 Инструкция по монтажу
- Daikin EKHBRD014ADV17 Инструкция по эксплуатации
- Daikin EKHBRD014ADV17 Инструкция по монтажу
- Daikin EKHBRD016ADV17 Инструкция по эксплуатации
- Daikin EKHBRD016ADV17 Инструкция по монтажу
- Daikin EKHBRD011ADY17 Инструкция по эксплуатации
- Daikin EKHBRD011ADY17 Инструкция по монтажу
- Daikin EKHBRD014ADY17 Инструкция по эксплуатации
- Daikin EKHBRD014ADY17 Инструкция по монтажу