Comet CM 30 S [13/100] Blower function

Comet CM 30 S [13/100] Blower function
USE
WET & DRY VACUUM CLEANER PRECAUTIONS
Dry vacuum cleaner
see g.
Wet vacuum cleaner
see g.
26 The equipment should not be used to pick up
water from containers, lavatories, tubs, etc.
14 These machine are not designed for picking
up health endangering dusts or inammable/
explosives substances.
23 Before vacuuming liquids, check the oat
functions correctly. When vacuuming liquids,
and when the tank is full, a  oat closes the
suction opening, and the vacuum operation
is interrupted. Then switch o the machine,
disconnect the plug and empty the tank.
Regularly clean the water level limiting device (
oat) and examine it for signs of damage.
25 If foam/liquid should come from the machine
exhaust switch o immediately.
If the appliance is used with especially ne dust
(size below 0.3 µm) the lter supplied will re-
quire cleaning more frequently. For especially
demanding applications, the use of specic
lters supplied as an optional (Hepa) may be
necessary.
ASH VACUUM PRECAUTIONS
see g.
Do not vacuum hot ashes, burning coals
or liquids. Make sure that the material to be
vacuumed is not burning.
If ashes hose C becomes hot during use, turn
the device o immediately and let it cool.
Do not empty the drum into a container
which is easily inammable and make sure
that the ashes are completely cool.
Always check the contents of the drum; the
ashes must never reach the suction inlet H.
If there should be a reduction in the suction power:
1) Be sure that switch is in o position (0) OFF
and connect the machine to a suitable socket.
The machine must be always kept on horizontal
bases, in a safe and stable way.
Insert the suitable lters for the proper use.
Never use the appliance without lters .
Use the most suitable accessories for the reques
-
ted usage.
Put switch on (-) ON position in order to start the
machine.
(see g.
) Pneumatic lter shaker T If there
should be a reduction in the suction power, ope
-
rate the lter reset buton T several times to reset
the lter .
When job is over, switch o (0) OFF and keep
away the plug from the socket.
2) If the drum’s suction force decreases, verify how
full drum I is and if necessary, empty it.
3) Check if the net of drum F is clogged. If necessary,
clean it with a jiggling movement, a brush or by
washing it.
When the stove or replace has been cleaned, the
appliance and suction lter must then be cleaned