HAWK HD 1115R — инструкция по эксплуатации насосов: установка и безопасность [19/31]
Превью страниц
Страница 19 /
31
![HAWK NMT 1820RN (1450 об/мин) [19/31] Installation and assembly](/views2/1804314/page19/bg13.png)
Instructions Manual
Motorpumps
Cod. doc. M.I. EP-18
Issue 0
Page 19 of 31
This Manual remains the property of the Manufacturer; it may not be reproduced or copied, even partially.
For any other uses than those described in section 2 and section 4.1
In any other operating conditions than those described in section 2.2
For pumping liquids that are flammable, toxic, corrosive or with an unsuitable density or temperatures higher than those
specified in the technical data listed in this document or on the product’s specifications label
For pumping drinking water
For food uses
For pharmaceuticals
In potentially explosive atmospheres (see the specific Hawk product range)
The Manufacturer reserves the right to review the terms of the guarantee if the equipment is used for any
other purpose than those mentioned above.
5 INSTALLATION AND ASSEMBLY
Read this chapter with due care before starting to install the machine.
Failure to install the pumping system correctly can result in injury or damage to property: it is important
to follow all the points below.
The electric pump-motor assembly is constructed by directly coupling the pump crankshaft and the hollow shaft of the motor.
Read the following points carefully:
The pump should be installed horizontally with respect to its base to facilitate optimum lubrication, on an anti-
vibration base.
Check the direction of rotation of the motor and the crankshaft (indicated near the crankshaft): they must be the
same.
The pump’s suction pipe must be proportional to the volume and its diameter must not be smaller than the
suction mouth. It is important there are as few bottlenecks on this line as possible (elbows, T couplings,
reductions, etc...). Each junction on the suction line must be sealed properly with Teflon tape or a similar product
to avoid leaks or air intake (cavitation). Cavitation is the formation of bubbles of steam in the liquid: their
implosion generates abnormal stress, which is very damaging for all pump parts. To safeguard optimum pump
life, avoid the circulation of liquid containing sand or other solid particles as this affects the efficiency of valves,
the plungers and seals.
This can be prevented by fitting an oversized filter on the suction pipe with respect to the pump volume. The
filter should be cleaned regularly.
The delivery pipe must be able to support the operating pressure of the pump. Excessively narrow passages can
result in lance pressure loss.
To prevent injury and damage to the pump, it is essential to fit a pressure control valve and a safety valve to
prevent the pressure accidentally exceeding its operating level. Contact our technical staff before fitting
these valves. To keep the system pressure under control, a pressure gauge should be fitted on the delivery line
with an appropriate bottom scale.
With regard to electrical components, 1.5mm cables (panels for motors up to 4Kw) and 2.5mm cables (panels
for motors up to 7.5Kw) are recommended.
Further assessments should be discussed with the Manufacturer as necessary.
Содержание
120- Instructions manual
- Leuco s p a
- Instructions manual
- General information
- Aim and contents
- Structure of the manual
- Motorpumps
- Intended recipients definitions
- Storage
- Instructions manual
- Service centres
- Leuco s p a via colletta 20 42124 reggio emilia re italy
- Motorpumps
- Manufacturer
- Ec mark and certification declaration of incorporation
- Symbols used in the manual
- Instructions manual
- Motorpumps
- Guarantee
- Instructions manual
- Motorpumps
- General description
- Main parts
- Instructions manual
- Motorpumps
- Technical characteristics
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Local conditions
- Motorpumps
- Instructions manual
- Instructions manual
- Pressurised liquids
- Motorpumps
- High temperatures
- General safety instructions
- Vibration
- Stability
- Safety
- Instructions manual
- Residual risks
- Motorpumps
- Working safely
- Instructions manual
- Personal protective equipment
- Motorpumps
- Safety when using the pump
- Safety when using high pressure circuits
- Packing unpacking and transport
- Motorpumps
- Instructions manual
- Safety during lifting and handling
- Rules of conduct regarding the use of high pressure lance
- Motorpumps
- Instructions manual
- This manual remains the property of the manufacturer it may not be reproduced or copied even partially
- Safety during maintenance
- Page 15 of 31
- Issue 0
- Follow the instructions below whenever carrying out any maintenance or repair work depressurise the water system and disconnect the pump from any power source before starting any maintenance or repair work
- Failure to comply with these instructions may lead to situations of extreme danger
- Each motorpump is packed so that it is protected from stress and impact and will not be damaged during transport based on the amount of goods to be shipped and the final place of destination the packed pumps can be placed on a pallet to facilitate lifting and handling when unpacking check the parts are intact and they are the correct amount if any parts are damaged or missing contact your dealer or the manufacturer for instructions dispose of packing materials correctly according to legal obligations different means of transport may be used to ship hawk motorpumps road rail sea or air depending on their final destination secure the packs to the vehicle properly during transport to prevent movement
- Cod doc m i ep 18
- As evidenced by the dimensional specifications the product described in this document requires special handling with suitable as evidenced by the dimensional specifications the product described in this document requires special handling with suitable lifting devices for example belts and hoists
- Instructions manual
- Products used
- Product labels
- Motorpumps
- First aid
- What the first aider does
- The emergency call
- Other signs on the equipment
- Motorpumps
- Instructions manual
- Motorpumps
- Intended use
- Injuries
- Instructions manual
- Improper uses
- Bleeding
- Motorpumps
- Installation and assembly
- Instructions manual
- Responsibilities of the customer user
- Motorpumps
- Instructions manual
- Pre commissioning instructions
- Motorpumps
- Long periods of inactivity
- Instructions manual
- Operation
- Motorpumps
- Instructions manual
- The table below is an example of how to choose the nozzle correctly based on the pump s specifications maximum pressure and flow rate factor the table gives an example pump with pmax 100 bar and flow rate 15 l min
- Pag 24 di 31
- Nozzle table
- Motorpumps
- Instructions manual
- Cod doc m i ep 18
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Instructions manual
- General maintenance
- Motorpumps
- Maintenance
- Motorpumps
- Instructions manual
- Instructions manual
- Trouble shooting
- Troubleshooting
- Motorpumps
- Spare parts
- Dismantling and disposal
- Motorpumps
- Instructions manual
- Attachments
Похожие устройства
-
HAWK AQUA 1320R (1450 об/мин)Деталировка -
HAWK AQUA 1320R (1450 об/мин)Инструкция по эксплуатации -
HAWK XLT 2520IRДеталировка -
HAWK XLT 2520IRИнструкция по эксплуатации -
HAWK HD 1115RДеталировка -
HAWK XXT7015IR (1450 об/мин)Деталировка -
HAWK XXT7015IR (1450 об/мин)Инструкция по эксплуатации -
HAWK XXT5520IR (1450 об/мин)Деталировка -
HAWK XXT5520IR (1450 об/мин)Инструкция по эксплуатации -
HAWK AQUA 1320RN (1450 об/мин)Деталировка -
HAWK AQUA 1320RN (1450 об/мин)Инструкция по эксплуатации -
HAWK AQUA 1520RN (1450 об/мин)Деталировка
Подробная инструкция по установке и эксплуатации насосов. Узнайте о правильной установке, предотвращении повреждений и обеспечении безопасности при использовании.