General-Fujitsu ASG30FBBJ [11/40] Compact cassette

General-Fujitsu AWHZ18LBC [11/40] Standard equipment
058
COMPACT CASSETTE
INVERTER
Specifications
Wireless R.C.
Model : AUGG12LVLA-A / AUGG18LVLA-A / AUGG24LVLA
Grille is an option
Capacity
EER
COP
Running Current
Moisture Removal
Airflow Rate (High)
Sound Pressure
Net Dimension H
x
W
x
D
Net Weight
Piping Connections (Small / Large)
Max Height Difference
Operation Range
Cooling
Heating
Drain Pipe Diameter (I.D./O.D.)
Max Pipe Length (Pre-Charge)
Refrigerant
Cassette Grille
Heating
Cooling/HeatingInput Power
Power Source
Cooling
Cooling
Indoor
Outdoor
Indoor (High)
Outdoor
Heating
Cooling/Heating
Indoor / Grille
Outdoor
°CDB
mm
m
kg(lbs)
mm
kW
kg(lbs)
A
W/W
m
3
/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
BTU/h
kW
BTU/h
Model No.
Indoor unit
Outdoor unit
AUGG12LVLA-A
AOGG12LBLA-A
230/1/50
3.50
11,950
4.10
14,000
0.99/1.11
3.54
3.69
4.5/5.1
1.2
37
47
600
1,700
245×570×570/50x700x700
15.0(33)/2.6(6)
578×790×300
40.0(88)
6.35/9.52
19.4/25.4
25(15)
15
-10 to 46
-15 to 24
R410A
UTG-UFGD-W
AUGG18LVLA-A
AOGG18LBLA-A
230/1/50
5.20
17,700
6.00
20,500
1.55/1.66
3.35
3.61
7.0/7.4
2.2
38
50
680
2,000
245×570×570/50x700x700
15.0(33)/2.6(6)
578x790x300
40.0(88)
6.35/12.70
19.4/25.4
25(15)
15
-10 to 46
-15 to 24
R410A
UTG-UFGD-W
AUGG24LVLA
AOGG24LALA
230/1/50
6.80
23,200
8.00
27,300
2.21/2.26
3.08
3.54
9.7/9.9
2.7
49
52
930
2,470
245×570×570/50x700x700
16.0(35)/2.6(6)
578x790x315
44.0(97)
6.35/15.88
19.4/25.4
30(15)
20
-10 to 46
-15 to 24
R410A
UTG-UFGD-W
Adoption of laminar wing
Spin direction Airflow direction
Quiet
Airflow runs through smoothly along
the laminar wing
No airflow separation
Laminar wing
Quiet
2-stage turbo fan
High efficiency design by 2 stage structure
Quiet quality
Previous turbo fan
2-stage turbo fan
1-stage
+
2-stage
2 stage
Fast
Slow
Wind
velocity
In the case of a conventional
fan, the air outlet range was
narrow as the airflow moved
to the motor side which
meant the velocity of air
passing through the heat
exchanger was uneven.
Designed by CFD-analysis (fluid) simulations
Optimization of wing form (laminar wing type)
and wing number (7 blades each)
Heat exchange
efficiency:
20%UP
A evenly spread air distribution across
the heat exchanger is possible due to
the new 2 stage turbo fan which
produces two separate airflow streams.
059
SPLIT / INVERTER
Dimensions Models: (Unit : mm)AUGG12LVLA-A / AUGG18LVLA-A / AUGG24LVLA
A
B
C
D
Grille cover
2
1
3
: standard equipment
During installation, maintenance and operation,
the drain pump and kit can be checked easily.
Maintenance of the fan motor and fan can be done easily after taking
off the panel as the bell mouth of the fan can be removed easily.
A : Fan motor
C : Bell-mouth
B : 2-stage turbo fan
D : Panel
Easy maintenance
1
Maintenance of fan motor and fan
2
Long life filter
3
Adaptation of
transparent drainage parts
700
30
49
700
530(Bolt pitch)
540(Bolt pitch)
570(Indoor unit)
580-660(Ceiling openings)
75
116
222
262
58
124
135 250
Control box
Liquid pipe Gas pipe
Ceiling
Side view
Top view
Side view
Bottom view
30
9940
250135
102
108
146
40
245
Previous model
New model
24 type
Compact design
Worlds first 24,000Btu model in the compact cassette category
(Easy installation by taking off ceiling panel of 600 x 600 size)
570
570
570
570
570 570
590 590
24 type
830
830
Low ambient operation
High lift drain pump
700mm
50
40
30
20
10
0
-10
-15°C
Cooling
24°C
Heating
-10°C
46°C
Optional parts
Air Outlet Shutter Plate:
Wired Remote Controller:
Insulation Kit For High Humidity:
External Connect Kit:
External Control Set:
Fresh Air Intake Kit:
Simple Remote Controller:
UTR-YDZB
UTY-RNNGM
UTZ-KXGC
UTY-XWZX
UTD-ECS5A
UTZ-VXAA
UTY-RSNGM

Содержание

Скачать