General-Fujitsu ASG30FBBJ [39/40] High static pressure duct

General-Fujitsu AOG18FNAK [39/40] High static pressure duct
114
Specifications
Model : ARG60FUAK
[
3phase
]
/ ARG60UUAK
[
3phase
]
Wired type
(With Weekly / Setback Timer)
HIGH STATIC PRESSURE DUCT
CONSTANT SPEED
ARG18ALCH
AOGA18ADTH
Capacity
EER
COP
Running Current
Moisture Removal
Airflow Rate (High)
Net Dimension H
x
W
x
D
Net Weight
Piping Connections (Small / Large)
Max Height Difference
Operation Range
Cooling
Heating
Drain Pipe Diameter (I.D./O.D.)
Max Pipe Length (Pre-Charge)
Refrigerant
Heating
Cooling/HeatingInput Power
Power Source
Cooling
Cooling
Indoor
Heating
Cooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)
mm
kW
kg(lbs)
A
W/W
m
3
/h
I/h
mm
V/ Ø/Hz
kW
BTU/h
kW
BTU/h
Model No.
Indoor unit
Outdoor unit
ARG60FUAK
AOG60FMAYT
ARG60UUAK
AOG60UMAYT
400/3/50
16.5
56,300
19.5
66,600
6.06/5.54
2.72
3.52
10.2/9.8
4.0
3,500
400×1,050×500
50(110)
1,290×900×330
118(260)
9.52/19.05
23.4/25.4
50(20)
30
0 to 43
-10 to 24
R410A
400/3/50
16.5
56,300
í
í
5.93
2.78
í
10.0/í
4.0
3,500
400×1,050×500
50(110)
1,290×900×330
114(251)
9.52/19.05
23.4/25.4
50(20)
30
0 to 43
í
R410A
115
SPLIT / CONSTANT SPEED
Dimensions Models:
Model:
(Unit : mm)
ARG60AUAK / ARG60RUAK
Front view
Top view
Side view (L)
Side view (R)
Rear view
88
400
1,080(Bolt pitch)
1,000
862
851
1,050 85
371
356
208
41
123
139
108
1
2
3
4
324
14
295
585
500(Bolt pitch)
71
Refrigerant piping flare connection (Liquid)
Refrigerant piping flare connection (Gas)
Drain piping connection
2
1
3
1.Wired Remote Controller with Thermo Sensor
• Room temperature sensor selection
• WEEKLY timer
• Temperature SET BACK timer
• Group control system
• Energy saving
Auto changeover (for heating)
• Hot start (for heating)
• Child lock
• Dual remote controllers
<Optional parts>
• AUTO restart
Pursuance of amenity performance
Various remote controllers and sensors can be selected
2.Simple Remote Controller (Optional Parts)
Optional parts
Simple Remote Controller: UTY-RSNGM
Long-Life Filter: UTD-LF60KA
Remote Sensor Unit: UTY-XSZX
External Control Set: UTD-ECS5A
IR Receiver Unit: UTY-LRHG1
Low noise
Turbulent air flow is reduced by cutting off the corners of
conventional indoor unit front panel and fan case
Heat exchanger
Plastic fan
(ø225mm)
Casing
(Plastic)
500mm
400mm
Plastic fan [45dB(A)]
Low noise is realized by adopting plastic case, plastic fan.
* Model : Material (At 100Pa :
Actual noise measurement value)
123
3.Remote Sensor (Optional Parts)
Long life filter (Optional Parts)
Output port (Built-in)

Содержание

Скачать