General-Fujitsu AOH24USBV2 [11/27] Error contents

General-Fujitsu AOH24USBV2 [11/27] Error contents
INDOOR UNIT (Wall Mounted type)
:
Fast flashing
:
Slow flashing
When an error occurs, "Large division indication" is indicated first.
Secondly, "Small division indication" is indicated by pushing "Test" button of remote controller.
Operation lamp
: Red lamp
Timer lamp : Green lamp
Error contents Error contents
thermistor error Red lamp (2 times) thermistor error (room temp.)
----- -----
-----
-----
-----
-----
Green lamp
Red lamp
Green lamp
Red lamp
Green lamp
Red lamp
Green lamp
Red lamp
Green lamp
Red lamp
Green lamp
Red lamp
Green lamp
Red lamp
Green lamp
Red lamp
Green lamp
Red lamp
Green lamp
(2 times)
thermistor error (heat exchanger)
(4 times) MANUAL AUTO button error
(indoor unit ) Green lamp (2 times)
power source Hz decision error
(4 times)
serial error Red lamp (5 times) serial reverse transmission error
Green lamp (2 times)
serial order transmission error
(3 times)
fan motor error Red lamp (6 times) lock error
(indoor unit)
thermistor error
(outdoor unit)
Green lamp
Red lamp
Green lamp
(2 times)
r.p.m error
(3 times)
(2 times)
LED indication LED indication
Small division indicationLarge division indication
ERROR CONTENTS
(3 times)
control unit error
(indoor unit )
(indoor unit )
circuit board error
Red lamp
INDOOR UNIT (CASSETTE TYPE)
: Fast flashing : Slow flashing
OPERATION lamp
TIMER lamp
Error display
Error contents
SWING lamp
Goes off
Goes off
Goes off
Goes off
Goes off
Goes off
4 times
2 times
3 times
5 times
6 times
Model information abnormal (permanent type)
Drain abnormal (permanent type)
Room air temperature thermistor open circuit
Room air temperature thermistor short circuit
Indoor fan abnormal
Piping thermistor open circuit
Piping thermistor short circuit
Indoor unit - outdoor unit miswiring
102006.02.03