Haier HSU-07LE03 [14/78] 1 1 automatic running

Haier HSU-07LE03 [14/78] 1 1 automatic running
+6807,LE03 )XQFWLRQV DQG &RQWURO
 )XQFLWLRQVDQG&RQWURO
'RPHVWLF$LUFRQGLWLRQ
1
Including brief introduction to air conditioners of series models and electric control function.
5-1 Brief introduction to electric control function
5-1-1 Automatic running
When the running mode is turned to automation after starting the system, the system will
first determine the running mode according to the current room temperature and then will run
according to the determined mode. Tr in the following selection conditions means room
temperature, Ts means setting temperature, Tp means temperature of indoor coil pipe
Trı26ć running refrigerating mode Ts=26ć
Tr<26ć running fan mode
After turning to the automation mode, the running mode can be switched between
refrigerating mode, fan mode and heating mode according to the change of the indoor ambient
temperature.
5-1-2 cool running
when Tr t Ts, outlet air from compressor is on and indoor fan motor run at fixed wind speed.
When Tr Ts, outlet air from compressor is off ,
and when Tr > Ts, outdoor fan motor and compressor are on.
5-1-3 Dehumidification running
The compressor, outdoor fan and indoor fan will run as per the following working pattern so as to
realize the refrigerating running of dehumidification:
ķ Tr> Ts+2ć, compressor, outdoor fan run continuously, indoor fan runs as per setting wind speed
(State 1);
ĸ Ts+2 ćıTrıTs, compressor, outdoor fan run intermittently with 10 minutes ON, 6 minutes
OFF. (Compressor and outdoor fan are synchronous) indoor fan runs in fixed lower wind speed, and
will cease at the stand-by time of 3 minutes (State 2)
Ĺ Tr <Ts, compressor, outdoor fan ceases, indoor fan runs in lower wind speed. (State 3)
State1
State2
State3
Ts-1 Ts Ts+2 Ts+3