Haier HSU-08HK03 [18/18] Trouble shooting
Содержание
- Operation manual 1
- Split type room air conditioner 1
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Safety instructions and warnings 3
- Cautions 4
- Specifications 4
- The machine is adaptive in following situation 4
- Indoor unit 5
- Outdoor unit 5
- Parts and functions 5
- Buttons and display of the remote controller 6
- Clock set 6
- Operation 6
- Parts and functions 6
- Load the battery 7
- Loading of the battery 7
- Operation 7
- Power failure resume please set and apply as necessary 7
- Put on the cover again confirmation indicator 7
- Remote controller s operation 7
- Remove the battery cover 7
- 1 unit start 8
- 2 select operation mode 8
- 4 unit stop 8
- Auto run fan operation 8
- Enjoy yourself by just a gentle press 8
- Operation 8
- Cool heat and dry operation 9
- Operation 9
- P v a u 9
- 5 air flow direction adjustment 10
- 6 unit stop 10
- Cautions 10
- Left and right air flow adjustment manual 10
- Operation 10
- Up and down use remote controller 10
- Operation 11
- Qu q3 0 qq 11
- Timer on off 11
- Timer operation 11
- To cancel timer mode 11
- 1 after unit start select your desired operation mode 12
- 2 press timer button to change timer mode 12
- 3 time setting for timer on 12
- 4 time confirming for timer on 12
- 5 time setting for timer off 12
- 6 time confirming for timer off 12
- Operation 12
- Timer on off 12
- To cancel timer mode 12
- Health mode operation 13
- Operation 13
- Emergency operation 14
- Emergency operation and test operation 14
- Operation 14
- Removal of the restriction of emergency or test operation 14
- Test operation 14
- Comfortable sleep 15
- In cool mode 15
- In heat mode 15
- Operation 15
- Power failure resume function 15
- Cleaning of air filter 16
- Cleaning of remote controller 16
- Cleaning of unit casing 16
- Maintenance 16
- Better use of air conditioner 17
- Maintenance 17
- Never fail to observe the followings 17
- Before asking for service check the following first 18
- Trouble shooting 18
Похожие устройства
- Haier HSU-09LD03 Инструкция по эксплуатации
- Haier HSU-09LD03 Инструкция по монтажу
- Haier HSU-09LD03 Технические данные
- Haier HSU-09LD03 Руководство по эксплуатации
- Haier HSU-09RD03 Инструкция по эксплуатации
- Haier HSU-09RD03 Инструкция по монтажу
- Haier HSU-09RD03 Технические данные
- Haier HSU-09RD03 Руководство по эксплуатации
- Haier HSU-12RD03 Инструкция по эксплуатации
- Haier HSU-12RD03 Инструкция по монтажу
- Haier HSU-12RD03 Технические данные
- Haier HSU-12RD03 Руководство по эксплуатации
- Haier HSU-12LD03 Инструкция по монтажу
- Haier HSU-12LD03 Инструкция по эксплуатации
- Haier HSU-12LD03 Технические данные
- Haier HSU-12LD03 Руководство по эксплуатации
- Haier HSU-18CK03 Технические данные
- Haier HSU-18CK03 Инструкция по эксплуатации
- Haier HSU-18CK03 Руководство по эксплуатации
- Haier HSU-18HK03 Технические данные
Trouble shooting Before asking for service check the following first Phenomenon Cause or check points The system does not immediately restart When unit is stopped it won t restart immediately until 3 minutes have elapsed to protect the system When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner During unit operation or at stop a swishing or gurgling noise may be heard At first 2 3 minutes after unit start this noise is more noticeable This noise is generated by refrigerant flowing in the system During unit operation a cracking noise may be heard This noise is generated by the casing expanding or shrinking because of temperature changes Should there be a big noise from air flow in unit operation air filter may be too dirty Noise is heard Normal Performance inspection o This is because the system circulates smells from the interior air such as the smell of furniture cigarettes Smells are generated Mist or steam are blown out During COOL or DRY operation indoor unit may blow out mist This is due to the sudden cooling of indoor air c Does not work at all Multiple check 7 zj Is power plug inserted Is there a power failure Is fuse blown out Is the air filter dirty Normally it should be cleaned every 15 days Are there any obstacles before intel and outlet Is temperature set correctly Are there some doors or windows left open Is there any direct sunlight through the window during the cooling operation Use curtain Are there too much heat sources or too many people in the room during cooling operation Poor cooling H Application temp range of air conditioner 7 C 43 C 16