Haier HSU-22LV03 [11/32] Haier air conditione

Haier HSU-22LV03 [11/32] Haier air conditione
Haier air conditioner Edition: 1.0-061028
- 11 -
The memory function of power down is available, and the auto recovery function of
power on is optional. (In auto, heating, cooling, or defrosting status, press the “sleeping”
button 10 times within 5 seconds, and the auto recovery function of power on can be set
on/off. If the buzzer rings 4 times, the auto recovery function of power on is available;
If the buzzer rings 2 times, the auto recovery function of power on is unavailable.)
2.6 Alarm from indoor fan motor
After 120 seconds the indoor fan motor is charged, and the impulse from fan motor is
not detected, then stops outputting voltage to indoor fan motor, send alarm signals.
MODEL PCB The SW2 select “25” or “35”
HSU-22LV03 0010403462 35