Haier HSU-18C03/V(ZXF) [100/101] Fan back
![Haier HSU-18C03/V(ZXF) [100/101] Fan back](/views2/1807709/page100/bg64.png)
97
Domestic Air Conditioner
10.3 Circuit Diagrams
Indoor Unit
HSU-09,12C03/VA(ZXF) Appendix
A
B
C
D
D
C
B
A
R54
2W/78K
R17
10k
C12
102
C13
104
C16
102
1
2
3
4
5
CN3
13
2
XT1
8M
DOWN STEP
LE FT ST EP
RIGHT STEP
FAR IN
FAR OUT
PG BAC K
R15
10k
R24
10K
IC9
TLP521
R18
4.7k
R41
1K
R42 10K
+5
C5 102
R30
10K
R28 1K
R27 10K
+5
R29
10K
Q2
2SC2412
Q1
2SC2412
)$5
1
2
CN9
1
2
ZJ 1
1
2
3
CN7
+5
FAN BACK
C43
103
+5V
R50
51K
R14 1K
+5
IC10
TLP3526
1
2
3
CON 1 2
C3 9
2UF 450V
+12V
R5 7
680
)$1
R8 3
1W-120ȍ
3*287
3
45
6
7
8 1
2
IC2
24C01A
+5
E6
4.7UF/50V
E7 4.7UF/50V
1
2
3
4
CN8
R44 1K
R45 1K
R35 3.3K 1%
R34 20K 1%
+5
PG OUT
ROOM
PIPE
ZJ/SH ORT
C2 104
R46
1K
C15
102
C10
102
C9
102
Q4
2SC2412
SDA
SCL
1
2
3
4
5
6
7
89
10
11
12
13
14
15
16
IC4
2003
1
2
3
4
5
6
7
89
10
11
12
13
14
15
16
IC5
2003
1
2
3
4
5
6
7
89
10
11
12
13
14
15
16
IC3
2003
B
A
D
C
B
A
C
C
D
B
A
C
D
B
A
UP STEP
+12
+12
+12
+12
C4
104
+5
C6
103/50V
+5
E5
100u/16v
C18
104/50V
+5
WH ITE
R22 22K
C37
104
R40 4.7K
R65
4.7k
C17
103/50v
STF
)/=
RL3
G5N -1A
RL1
G4A -1A-P
+12
&203
1
CON 2 1
220VL
RL4
G5N -1A
RL5
JAQ-1 12V
WFJ
STF
D1 0
RLS4148
1
CON20
COMP
COMP
FLZ
WFJ
R20 22K
R19 4.7 K
+5
R43 1K
R39
1K
R38
390
C8
102
E3
470U/16V
CT1
VR 1
D5
IN4148
+5
BD2
W04
R10 10K
BUZZ
1
2
3
4
CN6
㔥㒰
(
㑶
)
R36
1K
R37
10K
+5V
R8
10K
+5V
R7
10K
C14
104
BUZ1
BEEP-PKM13EPY-4002
Q5
2SC2412
R11
10K
R49
100
R9
4.7K
R1
1M
+5V
REC
R64
10K
R56
1K
Q8 2 SB1 18 2
+12V
HX F
R31
10K
+12V
C41
102
D2 RLS4 1 48
R2
10K
R3
1K
C1
102
YJKG
+5V
Q3
2SC2412
R23 4. 7K
1
2
3
4
5
CN4
02 IRQ
07
08
PTF4/TBCH0
PTF3/TBCH3
48
49
PTH1/KBD3
PTH1/KBD4
03
RST
21
VSS GND
GN DAVSS/VR E
45
60
PTC0
PTF7
10
13
PTE0/TXD NET OUT
56
VSSA GND
14
PTE1/RXD NET IN
PTE2/TACH0
15
25
PTG2/KBD2 STF
PTE3/TACH1
16
17
PTE4/SS COMP OUT
18
19
20
PTE5/MISO
PTE6/MOSI
PTE7/SPSCK
HX F/JY
FLZ
WFJ
PTC401
1
2
3
4
5
6
7
8
9
10
CN2
26
PA0 UP A
27
PA1 UP B
28
PA2 UP C
29
PA3 UP D
30
PA4 DOWN A
31
PA5 DOWN B
32
PA6 DOWN C
33
PA7 DOWN D
38
PTB4 LEFT D
(COOL/HEAT)
(LAR GE/ SMALL
˅
1
2
CN10
DOOR
R33
10K
R32
1K
+5v
C21
102
5 0 PTD4 DO OR
34
PTB0/ATD0CT
35
PTB1/ATD1ZJ/SH ORT
39
40
41
42
43
46
PTB5/ATD5
PTD6/ ATD6
PTB7/ATD7
PTD0
PTD1
PTD2
LEFT C
LEFT B
LEFT A
RIGHT D
RIGHT C
RIGHT B
47PTD3RIGHT A
VDDAREF 4 4
06
05
PTF1/TACH3
PTF2/TBCH2
EE DATA
EE SCL
57
CGMXFC
54
55
VDDA
VR EFH
59
58
OSC 1
OSC 2
51PTD5
HEALTH
RUN PTD6 / TACLK 5 2
53
62
63
64
PTD7
PTC2/MCLK
PTC3
PTC5
PTF0/TACH2 0 4REC
RED
BLUE
GR EEN
POW
22
36
37
PTB3/ATD3
PTB2/ATD2
VD D
PIPE
ROOM
09
NC
61
23
24
PTC1
PTG1/KBD1
PTG0/KBD0
CON18
ǃ
CON19
220N
1
2
3
CON13
1
CON14(R ED)
FLZ
JZKZ
C11
104
C19
104
C20
104
HXF
RL2
OEG-SS-112DM
DJR
1
CO N16(BLUE)
DJR
MC68HC908AB32
+12v
R12 1K R13
1K
Q7
S9013
Q6
S9013
1
2
3
CN12
+12v
R2522K
R26
4.7K
5v
11
12
PTF5
PTF6
Ultraviolet_A
Ultraviolet_C
Ultraviolet_Control
E1
1UF/16V
R4822K
C7
104/50V
C3
103
C4 2
104/50V
C29
104/50v
R5 3 1 K
SW1
220V-L
220V-N
D
R59
4.7K
1
CON15(
ⱑ
)
FLZ
220V-N
220V-L
STF
WFJ
A
12V
C
R66 27
C4 4
103/50V
C4 5
103/50V
C2 3
103/50V
C2 4
103/50V
C2 5
102/50V
C2 6
102/50V
C2 7
102/50V
C2 2
102/50V
C4 7
103/50V
E13
100u/16v
R69 100
R68 100
R67 100
R70 330
R71 330
R72 330
64
63
62
53
52
51
E12
100u/25v
1
CON 2 1
220VL
FU SE1
T3. 15A
C4 0
104/275V
LX1
ZE 1
S14K350
1
2
3
4
C48
104/50V
IC8
Q8 1 7 C
L1 20UH
12V
IC7
7805
+5
T1
TRAN1 -3
C33 222/300VAC
E4
220U/16V
E1 0
1000U/25V
E9
22U/25V
D6
UF4007
D8 UF302
R60
1.3
ྚ
2W
R61
4.7K
R55
560
D11
1N4007
C28
104
R52 3.6
/3W
R51
47K/2W
R58 27
C30102
C31
472/1KV
C35
104
D7
10V/0.5V
E8
22U/450V
220V-L
220V-N
E1 1
470U/25V
C36
104
IC13
STD2NBP60
AD J
1
FB
2
CS
3
GN D
4
DR V
5
Vcc
6
NC
7
HV
8
IC6
NCP1200P60
R75
15
R62
39K
D9
D1 3 D1 4
D1 2
S
C
D
R76
10K
E1 4
100U/16V
C34
104
1
2
3
4
5
6
7
8
9
10
TO DISP
CON5-1
R85 330
C3 8
102/50V
61
TIM
B3 P5 -VH-3/
MOL-35979-0314
(BLUE
˅
R16
10k
+5
D15
RLS4148
Q9
2SC2412
DJR
R21 4. 7K
SW2
R73
4.7K
5
.
'
9:
L2
125UH
&
X)9
Содержание
- On off 1
- Caution in repair 4
- Introduction 4
- Safety cautions 4
- Warning 4
- Cautions regarding products after repair 5
- Domestic air conditioner 5
- Hsu 18 22c03 v zxf introduction hsu 18 22c03 v zxf introduction 5
- Warning 5
- Caution 6
- Domestic air conditioner 6
- Hsu 18 22c03 v zxf introduction 6
- Warning 6
- Caution 7
- Domestic air conditioner 7
- Hsu 18 22c03 v zxf introduction 7
- Inspection after repair 7
- Warning 7
- Domestic air conditioner 8
- Hsu 18 22c03 v zxf introduction 8
- Icon type of information description 8
- Icons are used to attract the attention of the reader to specific information the meaning of each icon is described in 8
- The table below 8
- Using icons 8
- Using icons list 8
- 1 11 imer function 16
- Function of main thermistor 16
- Hour 1 hour 6hours 16
- T hour 16
- 18 2 c03 v zxf 17
- Indoor unit 17
- Room sensor 17
- Value of thermistor 17
- 18 2 c03 v zxf 18
- Domestic air conditioner 18
- Domestic air conditioner 19
- Hsu 18 2 2 c03 v zxf functions and control 19
- B25 50 3700k 3 21
- Domestic air conditioner 21
- Hsu 18 2 2 c03 v zxf functions and control 21
- Pipe sensor 21
- R25 10k 3 21
- Domestic air conditioner 22
- Hsu 18 2 2 c03 v zxf functions and control 22
- Domestic air conditioner 23
- Hsu 18 2 2 c03 v zxf functions and control 23
- Domestic air conditioner 24
- Hsu 18 2 2 c03 v zxf functions and control 24
- System configuration 25
- Cautions 26
- Contain no fluorochloric hydrocarbon 26
- Disposal of the old air conditioner 26
- Disposal of the packaging of your new air conditioner 26
- Instruction 26
- Safety instructions and warnings 26
- Cautions 27
- Specifications 27
- The machine is adaptive in following situation 27
- Caution 28
- Cautions 28
- Installation 28
- Safety instruction 28
- Warning 28
- Caution 29
- Cautions 29
- Domestic air conditioner 29
- Hsu 18 22c03 v zxf system configuration 29
- Warning 29
- Domestic air conditioner 30
- Hsu 18 22c03 v zxf system configuration 30
- Indoor unit 30
- Outdoor unit 30
- Parts and functions 30
- Parts and functions 32
- Fan speed selection 38
- Heat operation 38
- Operation 38
- Remote controller 38
- Select operation mode 38
- Select temp setting 38
- Unit start 38
- Unit stop 38
- Air flow direction adjustment 39
- For each press of button air flow direction on remote controller displays as follows according to different operation modes 39
- For each press of button remote controller displays as follows remote controller 39
- Left and right air flow direction 39
- Note when restart after remote turning off the remote controller will automatically memorize the previous set swing position 39
- Operation 39
- Remote controller 39
- Remote controller cool dry fan 39
- Remote controller heat 39
- Status display of air sending 39
- The horizontal louvers will swing according to the above positions 39
- The vertical flap will swing according to the above positions 39
- Up and down air flow direction 39
- Display board 40
- Operation 40
- Remote controller 40
- Sleep operation 40
- In power operation status 43
- Operation 43
- Power operation 43
- Remote controller 43
- Selecting of soft operation 43
- Soft operation 43
- To cancel power operation 43
- To cancel soft operation 43
- Health airflow operation 44
- Operation 44
- Press on off to starting 44
- Remote controller 44
- The cancel of the health airflow function 44
- The setting of health airflow function 44
- Maintenance 49
- To keep your air conditioner in good condition after season 49
- Before setting in high season 50
- Caution 50
- Cleaning the standard air filter 50
- Connecting the earthing cable 50
- Do not block the air inlet or outlet 50
- Earthing 50
- Maintenance 50
- No wet hand 50
- Plug in 50
- Before asking for service check the following first 51
- Trouble shooting 51
- 18 2 c03 v zxf 56
- Drawing for the installation of indoor and outdoor units 56
- Installation 56
- Necessary tools for installation 56
- 18 2 c03 v zxf 57
- Fix the unit to concrete or block with bolts 10mm and nuts firmly and horizontally when fitting the unit to wall surface roof or rooftop fix a supporter surely with nails or wires in consideration of earthquake and strong wind 57
- Fixing of outdoor unit 57
- If vibration may affect the house fix the unit by attaching a vibration proof mat 57
- Indoor unit 57
- Outdoor unit 57
- Power source 57
- Selection of installation place 57
- Selection of pipe 57
- Fit the level line 58
- 18 2 c03 v zxf 61
- Attaching drain elbow 61
- Connection 61
- Connection of pipes 61
- Easily demount cleaning of indoor unit 61
- Half union flare nut 61
- Installation of outdoor unit 61
- Outdoor unit 61
- Spanner torque wrench 61
- 18 2 c03 v zxf 62
- 18 2 c03 v zxf 63
- Check for installation and test run 63
- Check items for test run 63
- Correct incorrect 63
- Cutting and flaring work of piping 63
- Flare tooling die 63
- On drainage 63
- Pipe cutting is carried out with a pipe cutter and burs must be removed after inserting the flare nut flaring work is carried out 63
- Please install the drain hose so as to be downward slope without fail please don t do the drainage as shown below 63
- Please kindly explain to our customers how to operate through the instruction manual 63
- Please pour water in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor in case that the attached drain hose is in a room please apply heat insulation to it without fail 63
- Power source installation 63
- The power source must be exclusively used for air conditioner over i0a in the case of installing an air conditioner in a moist place please install an earth leakage breaker for installation in other places use a circuit breaker as far as possible 63
- 18 22c03 v zxf 76
- Hsu 18c03 v zxf 76
- Outdoor panel 76
- 18 22c03 v zxf 77
- 18 22c03 v zxf 79
- 18 22c03 v zxf 80
- 18 22c03 v zxf 81
- 18 22c03 v zxf 82
- 18 22c03 v zxf 83
- 18 22c03 v zxf 84
- 18 22c03 v zxf 85
- Hsu 22c03 v zxf 86
- Appendix 98
- Hsu 18 2 2 c03 v zxf appendix 98
- Piping diagrams 98
- Capacitor 99
- Compressor 99
- Device for fresh air 99
- Fan motor 99
- The 1 is optional part to 1 99
- To indoor unit 99
- Way valve 99
- Wire is connected from 4 marked with on terminal block 2 there are no dotted lines on cool only type marked with 1 see above for wiring of heat pump type 99
- Wiring diagram 99
- Y g br 99
- Yellow 99
- Circuit diagrams 100
- Domestic air conditioner 100
- Fan back 100
- Hsu 09 12c03 va zxf appendix 100
- Indoor unit 100
Похожие устройства
- Haier HSU-22C03/V(ZF) Инструкция по эксплуатации
- Haier HSU-22H03/V(ZF) Инструкция по эксплуатации
- Haier HSU-24C03/V(ZF) Инструкция по эксплуатации
- Haier HSU-24H03/V(ZF) Инструкция по эксплуатации
- Haier HCFU-18CF03 Руководство по эксплуатации
- Haier HCFU-18CF03 Сервис мануал
- Haier HCFU-18CF03 Руководство по монтажу
- Haier HCFU-18HF03 Инструкция по монтажу
- Haier HCFU-18HF03 Руководство по эксплуатации
- Haier HCFU-18HF03 Сервис мануал
- Haier HCFU-18HF03 Руководство по монтажу
- Haier HCFU-18CF03 Технические данные
- Haier HCFU-18CF03 Инструкция по монтажу