Haier HSU-18C03/U(ZXF) Инструкция по монтажу онлайн

No.0010558591
Installation Manual of Room Air Conditioner
No. Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain hose
Screw
Plastic cap
Drain-elbow
Cushion
1
1
A
B
C
D
E
F
G
2
3
4
5
6
7
2
1
1
4
1
4
Number
of
articles
Accessory parts
Optional parts for piping
Mark
Parts name
more than 5cm
more than 10cm
more than 60cm
more than 15cm
Non-adhesive tape
The marks from to in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
more than 10cm
more than 10cm
more than 10cm
Adhesive tape
Saddle(L.S) with screws
Attention must be paid to
the rising up of drain hose
Arrangement of piping directions
Rear left
Rear
right
Left
Below
Right
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
4X25
Piping hole cover
Read this manual before installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper 12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Explain sufficiently the operating means to the user
according to this manual.
A
G
G
F
A
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
C
D
E
Содержание
- Accessory parts 1
- Drawing for the installation of indoor and outdoor units 1
- Explain sufficiently the operating means to the user according to this manual 1
- Installation manual of room air conditioner 1
- Necessary tools for installation 1
- No 010558591 1
- Read this manual before installation 1
- Fix the unit to concrete or block with bolts 10mm and nuts firmly and horizontally when fitting the unit to wall surface roof or rooftop fix a supporter surely with nails or wires in consideration of earthquake and strong wind 2
- Fixing of outdoor unit 2
- Floor fixing dimensions of the outdoor unit unit mm 2
- If vibration may affect the house fix the unit by attaching a vibration proof mat 2
- Indoor unit 2
- Outdoor unit 2
- Power source 2
- Selection of installation place 2
- Selection of pipe 2
- Carry out based on the neighboring pillars or lintels the mounting plate must be fixed horizontally otherwise condensed water may overflow the water container then temporarily fasten the plate with one steel nail 2 make sure once more the proper level of the plate by hanging a thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 find the wall hole location a using a measuring tape 3
- Drawing of pipe 3
- Fitting of the mounting plate and positioning of the wall hole 3
- Fix to side bar and lintel a mounting bar which is separately sold and then fasten the plate to the fixed mounting bar 3
- Indoor unit 3
- Installation of the indoor unit 3
- Left left rear piping 3
- Making a hole on the wall and fitting the piping hole cover 3
- Rear piping 3
- Refer to the previous article when the mounting plate is first fixed for the position of wall hole 3
- When the mounting plate is first fixed 3
- When the mounting plate is fixed side bar and lintel 3
- Connecting the indoor outdoor electric cable 4
- Fixing the indoor unit body 4
- Indoor unit 4
- Removing the wiring cover 4
- When connecting the cable after installing the indoor unit 4
- When connecting the cable before installing the indoor unit 4
- Easily demount cleaning of indoor unit 5
- Indoor unit 5
- Installation instruction on the indoor part of the fresh air device optional 5
- See the installation from the fresh air sets for the installation of outdoor unit 5
- Attaching drain elbow 6
- Connection 6
- Connection of pipes 6
- Half union flare nut 6
- Installation of outdoor unit 6
- Outdoor unit 6
- Spanner 6
- Torque wrench 6
- Outdoor unit 7
- Purging method 7
- Check for installation and test run 8
- Check items for test run 8
- Correct incorrect 8
- Cutting and flaring work of piping 8
- Flare tooling die 8
- On drainage 8
- Pipe cutting is carried out with a pipe cutter and burs must be removed after inserting the flare nut flaring work is carried out 8
- Please install the drain hose so as to be downward slope without fail please don t do the drainage as shown below 8
- Please kindly explain to our customers how to operate through the instruction manual 8
- Please pour water in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor in case that the attached drain hose is in a room please apply heat insulation to it without fail 8
- Power source installation 8
- The power source must be exclusively used for air conditioner over i0a in the case of installing an air conditioner in a moist place please install an earth leakage breaker for installation in other places use a circuit breaker as far as possible 8
Похожие устройства
- Haier HSU-18C03/U(ZXF) Инструкция по эксплуатации
- Haier HSU-18C03/U(ZXF) Сервис мануал
- Haier HBU-18CC03 Инструкция по эксплуатации
- Haier AB182ACMCA Инструкция по эксплуатации
- Haier AU182AFMCA Инструкция по эксплуатации
- Haier HBU-18HC03 Инструкция по эксплуатации
- Haier HBU-18HC03 Сервис мануал
- Feron CL592 (41643) Инструкция по эксплуатации
- Feron CL592 (41643) Презентация
- Feron CL590 (41635) Инструкция по эксплуатации
- Feron CL590 (41635) Презентация
- Feron CL574 (41652) Инструкция по эксплуатации
- Feron CL574 (41652) Презентация
- Feron CL572 (41647) Инструкция по эксплуатации
- Feron CL572 (41647) Презентация
- Feron CL572 (41648) Инструкция по эксплуатации
- Feron CL572 (41648) Презентация
- Feron CL573 (41650) Инструкция по эксплуатации
- Feron CL573 (41650) Презентация
- Feron CL572 (41649) Инструкция по эксплуатации