Haier HSU-18C03/U(ZXF) [5/8] Indoor unit
![Haier HSU-09C03/U(ZXF) [5/8] Indoor unit](/views2/1808704/page5/bg5.png)
Indoor unit
Two ways for the installation of indoor part, as illustrated:
Way One : When
the pipes go from the back of the indoor unit, you can connect the fresh air tube with the outlet joint
on the two sides of the frame,and then fix it at the pipe exit of the frame
Way Two :
When installing the side outlet pipe,connect the fresh tube and the outlet joint ,and then fix it on the left side
or right side of the frame.Outlet pipe is connected with the pipe hole cover by the pipe lid.
5.Installation instruction on the indoor part of the fresh air device(optional)
To indoor unit
To outdoor fresh air motor
The connecting method of
fresh air box signal wire
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is H05RN-F or H07RN-F.
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
5
6.Easily-demount cleaning of indoor unit
1.Top inlet can be taken down
Open the inlet grille, press the claw of the clip on the unit,then
take down the top inlet.(according to figure 1)
2.Vertical flap can be taken down
Overturn the vertical flap, press the claw of the clip ,then take
down vertical flap.(according to figure 2)
3.Horizontal louvers can be taken down
After taking down vertical flap.Horizontal louvers are appeared,draw
the middle louver,and take down the horizontal louvers .
(according to figure 3)
For the units with
fresh air function
Installation way One Installation way Two
See the Installation from the fresh air sets for the installation of outdoor unit.
YEL/GRN
YEL/GRN
Indoor unit
Outdoor unit
RED
RED
BLK
BLK
WHT
WHT
Connecting wiring(with fresh function): 3G1.5mm
2
+2x0.75mm
2
Power cable: more than 3G1.5mm
2
claw of the clip
Figure 1
Figure 2
Figure 3
Daff
Connecting wiring(without fresh function): 4G1.5mm
2
Lid for right piping
Lid for left piping
Change-for-fresh-air tube
Drain hose
Fix with adhesive tape
Outlet joint
Fresh air tube
Outlet joint
(in guard ring)
Guard ring
Содержание
- Accessory parts 1
- Drawing for the installation of indoor and outdoor units 1
- Explain sufficiently the operating means to the user according to this manual 1
- Installation manual of room air conditioner 1
- Necessary tools for installation 1
- No 010558591 1
- Read this manual before installation 1
- Fix the unit to concrete or block with bolts 10mm and nuts firmly and horizontally when fitting the unit to wall surface roof or rooftop fix a supporter surely with nails or wires in consideration of earthquake and strong wind 2
- Fixing of outdoor unit 2
- Floor fixing dimensions of the outdoor unit unit mm 2
- If vibration may affect the house fix the unit by attaching a vibration proof mat 2
- Indoor unit 2
- Outdoor unit 2
- Power source 2
- Selection of installation place 2
- Selection of pipe 2
- Carry out based on the neighboring pillars or lintels the mounting plate must be fixed horizontally otherwise condensed water may overflow the water container then temporarily fasten the plate with one steel nail 2 make sure once more the proper level of the plate by hanging a thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 find the wall hole location a using a measuring tape 3
- Drawing of pipe 3
- Fitting of the mounting plate and positioning of the wall hole 3
- Fix to side bar and lintel a mounting bar which is separately sold and then fasten the plate to the fixed mounting bar 3
- Indoor unit 3
- Installation of the indoor unit 3
- Left left rear piping 3
- Making a hole on the wall and fitting the piping hole cover 3
- Rear piping 3
- Refer to the previous article when the mounting plate is first fixed for the position of wall hole 3
- When the mounting plate is first fixed 3
- When the mounting plate is fixed side bar and lintel 3
- Connecting the indoor outdoor electric cable 4
- Fixing the indoor unit body 4
- Indoor unit 4
- Removing the wiring cover 4
- When connecting the cable after installing the indoor unit 4
- When connecting the cable before installing the indoor unit 4
- Easily demount cleaning of indoor unit 5
- Indoor unit 5
- Installation instruction on the indoor part of the fresh air device optional 5
- See the installation from the fresh air sets for the installation of outdoor unit 5
- Attaching drain elbow 6
- Connection 6
- Connection of pipes 6
- Half union flare nut 6
- Installation of outdoor unit 6
- Outdoor unit 6
- Spanner 6
- Torque wrench 6
- Outdoor unit 7
- Purging method 7
- Check for installation and test run 8
- Check items for test run 8
- Correct incorrect 8
- Cutting and flaring work of piping 8
- Flare tooling die 8
- On drainage 8
- Pipe cutting is carried out with a pipe cutter and burs must be removed after inserting the flare nut flaring work is carried out 8
- Please install the drain hose so as to be downward slope without fail please don t do the drainage as shown below 8
- Please kindly explain to our customers how to operate through the instruction manual 8
- Please pour water in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor in case that the attached drain hose is in a room please apply heat insulation to it without fail 8
- Power source installation 8
- The power source must be exclusively used for air conditioner over i0a in the case of installing an air conditioner in a moist place please install an earth leakage breaker for installation in other places use a circuit breaker as far as possible 8
Похожие устройства
- Haier HSU-18C03/U(ZXF) Инструкция по эксплуатации
- Haier HSU-18C03/U(ZXF) Сервис мануал
- Haier HBU-18CC03 Инструкция по эксплуатации
- Haier AB182ACMCA Инструкция по эксплуатации
- Haier AU182AFMCA Инструкция по эксплуатации
- Haier HBU-18HC03 Инструкция по эксплуатации
- Haier HBU-18HC03 Сервис мануал
- Feron CL592 (41643) Инструкция по эксплуатации
- Feron CL592 (41643) Презентация
- Feron CL590 (41635) Инструкция по эксплуатации
- Feron CL590 (41635) Презентация
- Feron CL574 (41652) Инструкция по эксплуатации
- Feron CL574 (41652) Презентация
- Feron CL572 (41647) Инструкция по эксплуатации
- Feron CL572 (41647) Презентация
- Feron CL572 (41648) Инструкция по эксплуатации
- Feron CL572 (41648) Презентация
- Feron CL573 (41650) Инструкция по эксплуатации
- Feron CL573 (41650) Презентация
- Feron CL572 (41649) Инструкция по эксплуатации