Haier HSU-12H03/R(DB) Сервис мануал онлайн [20/131] 613258

Haier HSU-09H03/R(DB) Сервис мануал онлайн [20/131] 613257
stops and to SSLO in silent running mode)and then slightly weak.
remains for If the compressor stops when the heat running starts, the wind volume is
idle 3 minutes weak
Restart of The wind volume is set by the remote-controler after the warm boot.
the compressor select the wind volume by the temperature in the automatic wind volume
modeDŽ
Refer to the temperature level control function
Frost-removing the indoor fan stops running in frost-removing mode.
Operation When the frost-removing process is over, the compressor is on,the wind
volume control is the same with warm boot
cooling The wind volume can be set to strong, medium and weak.
running Automatic wind volume function will decide the wind volume according
to the temperature
Moisture The wind volume can be set to strong, medium and weak.
removing
running
3RZHUIXO5XQQLQJ
ƵPowerful running for 15 minutes
.
ƵThe running ends the powerful running after 15 minutes
.
ƵThe mode switch ends the powerful running
.
ƵEnter into the silent mode, normal running mode or timed switching on mode to end
the powerful running
.
ƵWhen in automatic mode, there are powerful and silent functions for your choice.
ƵWhen the main unit is in cooling mode, it operates with powerful cooling or silent
cooling. When the main unit is in heating mode, it operates with powerful heating or
silent heathing. When the main unit is in wind-sending mode and moisture
removing, there are no powerful .
3RZHUIXO
Change the set temperature. With temperature adjusting function
Heating The wind volume is the automatic medium
When in frost removing mode, the outdoor unit does not accept the
communication signal for powerful running
After 15 minutes of powerful running, the compressor can not be off within 10
minutes
Powerful Change the set temperature. With temperature adjusting function
Cooling The wind volume is the automatic strong
After the compressor starts, there will be no low-intense running protection
within 3 minutes
6LOHQWUXQQLQJ

ƵSend the silent running signal to the outdoor unit
ƵThere is no silent mode for moisture removing and wind-sending.
+6809,12H03/R(DB)  Functions and control
Demastic Air Conditioners
17