)XQFLWLRQVDQG&RQWURO
0DLQIXQFWLRQVDQGFRQWUROVSHFLILFDWLRQRILQGRRUXQLW
Note: See the list of functions for the functions applicable to different models.
7HPSHUDWXUH$MXVWLQJIXQFWLRQ
Set temperature Ȍ This function will decide the outdoor-set’s running speed according to the
domestic temperature and the set temperature.
Ȍ Control the indoor blower fan according to the need for temperature adjusting
when the wind rate is automatic.
Ȍ Control the indoor blower fan according to the disc-tube temperature when
it’s running for heating.
Indoor environment Under the conditions of short circuit or open circuit, the indoor display will flash
temperature sensor an alarm and the indoor blower fan stops. When it returns to normal condtions,
specification the operation will come back to normal.
Short circuitTemperature: over 126ď. Sixteen scales: over F8H.
Resistance value: below 0.65 K. Voltage: over 4.85 V
Normal temperature Temperature: 25 ď. Sixteen scale: 40H
Resistance value: 23K . Voltage: 2.33 V
Disconnection temperature : below minus 31 ď. Sixteen scale: below 08H .
Resistance value: below 620K. Voltage: below 0.15 V
B index=4200 R(25ć)=23K
The frequency When the operation enters into the work mode, in order to insure the full
kept when the oil-returning some frequency should be kept for some time.
frequency rises
Indication time Indication frequency
Cooling Heating Frost removing Frequency kept
60 seconds 60 seconds 60 seconds 58 Hz
Modify the
The set temperature can be modified according to the units operation set
set temperature
mode, wind volume or whether it is under forceful running condition.
The modification of wind volume is only limited within the switch
between weak and medium of wind volume when it is under
heating mode.
Modification index table for set temperature
Mode Content of modification
M
odified variable
M
odified parameter
Operation mode modification ETBL0
4.67ć
Forceful operation modification ETBL1
6ć
Weak wind volume modification ETBL2
4.67ć
Heating
M
edium wind volume modification ETBL3
4.67ć
Operation mode modification ETBL4
-0.33ć
Cooling
Forceful operation modification ETBL5
-4ć
7HPSHUDWXUHVHFWLRQFRQWURO
+6809,12H03/R(DB)  Functions and control
Demastic Air Conditioners
13