Haier HSU-12H03/R(DB) [77/131] Thermistor or related abnormality indoor unit

Haier HSU-09H03/R(DB) [77/131] Thermistor or related abnormality indoor unit
7.4.1Thermistor or Related Abnormality (indoor unit)
,QGRRU'LVSOD\

(
(
(
(
(
(

0HWKRGRI
the temperatures detected by the thermistors are used to determine
W
hermistor errors
0DOIXQFWLRQ
'HWHFWLRQ
0DOIXQFWLRQ
when the thermistor input is more than 4.92V or less than 0.08V during compressor
'HFLVLRQ
operation.
&RQGLWLRQV
1RWH
The values vary slightly in some models
6XSSRVHGƵ
Faulty connector connection
&DXVHVƵ
Faulty thermistor
Ƶ
Faulty PCB
Troubleshooting
&DXWLRQ
Be sure to turn off power switch before connect or disconnect connector, or
else parts damage may be occurred.
Thermistor resistance check method:
Remove the connector of the thermistor on the PCB, and measure the resistance of thermistor using
tester.The relationship between normal temperature and resistance is shown in the value of indoor
thermistor.
notes:
E1: Room temperature sensor failure
E2: Indoor heat-exchange sensor failure
Thermistor resistance check
Is it normal?
Yes
NO
Replace the thermistor
Yes
Replace the indoor unit PCB
Is it normal?
Correct the connection
NO
Check the connector connection.
Demastic Air Conditioners
+6809,12H03/R(DB)
System Diagnosis
74