1. Automatic mode:
cold/warm type run mode:
After entering into this mode, the main control “MCU” determines the
corresponding work pattern according to the indorr temperature so as to maintain
the preset temperature (the temperature is 23℃ in heating mode, and 26℃ in
cooling mode). When Starting the machine for the first time, the machine enter
heating mode if the indoor temperature is or below 23℃ or enter cooling mode if
the indoor temperature is 23℃. After the unit enters heating mode and conducts
heating programme (the preset temperature is 23℃), When reaching halt
temperature of compressor, the compressor stops for 15 minutes. Then the
machine enter cooling mode if the temperature of inlet air detected is or above
27 , or ℃ the unit is still in heating mode.When the unit enters cooling mode
conducts cooling programme (the preset temperature is 26℃), compensation
temperature difference is cancelled automatically. When reaching halt temperature
of compressor, the compressor stops for 15 minutes. Then the machine enter
heating mode if the temperature of inlet air detected is or below 23 and ℃
compensation temperature is added automatically, or the unit is still in cooling
mode. When the machine is transfered to the automatic mode from other modes, it
will stop for 3 minutes if operating mode is changed (judge first and then work),
and then enter the judged temperature according to the temperature of indoor inlet
air.
*This mode includes the functions of timing, sleeping and so on. The machine
enter cooling sleep mode when entering heating mode and enter cooling sleep
mode when entering cooling mode.
2.Cooling run mode:
*cooling indicator is on.(runing indicator is on For HSU-09RA03)
*temperature control range : 16℃—30℃
*temperature control precision: ±1℃
*compressor can’t be controlled by temperature sensor within 2 minutes after it
starts.
*control character: when Tr (inlet air) ≥ Ts (temperature setting), outlet air from
compressor is on and indoor fan motor run at fixed wind speed. When Tr (inlet air) < Ts
(temperature setting), outlet air from compressor is off , and when Tr > Ts, outlet air from
compressor is on.
*wind speed control: (the temperature difference is 1℃)
auto: when Tr>=Ts+3℃, the wind speed is high;
when Ts+1℃≤Tr<Ts+3℃, the wind speed is medium.
When Tr<Ts+1℃, the wind speed is low.
When temperature sensor is off, the fan motor runs at low speed.
when the wind speed changes from low to high, there is no delay, and
when it changes from high to low, there is a 3-minutes delay before
conversion.
Manual operation: When unit is on the wind speed can be set to high, medium,
Содержание
- Air conditioner 1
- Introduction 1
- Trouble shuootin 1
- Page 2 2
- 3 4 5 6 7 1 8 3
- A description of coding rules of unit model 3
- B standard situation conditions 3
- Coding rules and descriptions are as follows 3
- Examples hsu 09lg03 it represents wall mounted split type cooling only air conditioner the cooling capacity is 9000btu h and the power supply is 220 230v 50hz g means the developing sequence 3
- Introductory remarks 3
- C series brief introduction 4
- Page 5 5
- Hsu 09rg03 6
- Specifications 6
- Hsu 12rg03 7
- Specifications 7
- Curves of performance 8
- Page 8 8
- 230v 50hz 1ph 9
- P16s225anc 9
- Performance curve 9
- Uf 450 vac 9
- 230v 50hz 1ph 10
- Cond temperature 10
- Performance curve 10
- Qx 23b030g 10
- Μf 450 vac 10
- Description and functions of main components and accessories 12
- Net dimensions for indoor unit 13
- And part lists 14
- Knock down drawings 14
- Domestic air conditioner 19
- Model hsu 09rg03 outdoor unit 19
- Domestic air conditioner 20
- Model hsu 12rg03 outdoor unit 20
- Abnormality diagnosing 31
- Express mode of malfunction 32
- I ndoor wi re di agram 34
- M o del h su 09rg03 hsu 12rg03 34
- Wiring diagram 34
- Brushless fan motor 35
- Capaci tor 35
- Fan motor 35
- Outdoor wi re di agram 35
- To i ndoor uni t 35
- Way valve 35
- Switch power 37
- Model hsu 09rg03 43
- Model hsu 12rg03 43
- Noise level test chart 43
- Noise level test chart and air velocity distribution 43
- Air velocity distribution for indoor unit 44
- Condition fan speed high operation mode fan voltage 230v 50hz 44
- Fig 1 top view flow control panel horizal lourer center 44
- Fig 2 top view flow control panel horizal lourer right and left 44
- Fig 3 top view flow control panel horizal lourer center 44
- Fig 4 top view flow control panel vertical lourer center 44
- Noise level test chart and air velocity distribution 44
- Installation manual 45
- Change for fresh air tube 50
- Installation instruction on the indoor part of the change for fresh air device 50
- Outlet joint back in guard ring 50
- Installation instruction on the outdoor part of the change for fresh air device 51
- Note after wiring the connecting terminals of outdoor unit and change fresh air as well as the wiring sheath should be placed in the change for fresh air box against the rain 51
- Remove the four screws of change for fresh air box from the back cover 2 use six screws to fix the change new wind box onto the designated position on the outdoor unit 3 remove two screws of the pipe junction of the change new wind box then insert the flared departure of the change for fresh air tube into the pipe junction and then fix with the screws 4 use four screws to fix the change for fresh air box onto the back cover as illustrated 51
Похожие устройства
- IGC IWF-600FC322 Сертификат
- IGC IWF-600FC322 Каталог
- IGC IWF-700F323 Инструкция по эксплуатации
- IGC IWF-700F323 Сертификат
- IGC IWF-700F323 Каталог
- IGC IWF-700F324 Инструкция по эксплуатации
- IGC IWF-700F324 Сертификат
- IGC IWF-700F324 Каталог
- IGC IWF-800F323 Инструкция по эксплуатации
- IGC IWF-800F323 Сертификат
- IGC IWF-800F323 Каталог
- IGC IWF-800F324 Инструкция по эксплуатации
- IGC IWF-800F324 Сертификат
- IGC IWF-800F324 Каталог
- IGC IWF-800FC322 Инструкция по эксплуатации
- IGC IWF-800FC322 Сертификат
- IGC IWF-800FC322 Каталог
- IGC IWF-900FC322 Инструкция по эксплуатации
- IGC IWF-900FC322 Сертификат
- IGC IWF-900FC322 Каталог