Haier AM36LP2VHA [2/5] Mrv s key features mrv s lineup
Содержание
- 36 48 56 2
- Built in handles and designed skid for handling and rigging ease two pipe refrigerant lines save time and resources multiple piping connections simplify any jobsite condition optional branch connector kits allow using flexfit indoor units for application flexibility 2
- High efficiency 2
- Highly efficient full dc inverter compressor and fan motor 21 serrated edge fan blade allows higher air movement at a lower sound level large coil and 2 stage sub cooling circuit increase performance when the demand is high air cooled electrical box helps increase reliability 2
- Mrv s key features mrv s lineup 2
- Mvhp036mv2aa mvhp048mv2aa mvhp056mv2aa 2
- Optimized comfort 2
- Pid pressure sensor enables more precise temperature control non reversing 4 way valve avoids temperature fluctuation and component stresses night time mode for quiet operation 2
- Outdoor unit specifications indoor unit specifications 3
- Accessories accessories 4
- Ductless wind baffle 4
- Panels 4
- Return air grilles supply air grilles 4
- For more info visit 5
- Limited warranty 5
- Pub no ó6 x0147 5
- Support 5
- Training 5
- Your customers turn to you for great results so offer them the performance and support you can only get from haier 5
Похожие устройства
- Haier AM36LP2VHA Руководство по монтажу
- Haier AM36LP2VHA Инструкция по монтажу
- Haier AM48LP2VHA Спецификация
- Haier AM48LP2VHA Инструкция по монтажу
- Haier AM48LP2VHA Технические данные
- Haier AM48LP2VHA Руководство по монтажу
- Haier AL24LP2VHA Спецификация
- Haier AL24LP2VHA Инструкция по монтажу
- Haier AL36LP2VHA Спецификация
- Haier AL36LP2VHA Инструкция по монтажу
- Haier AL48LP2VHA Спецификация
- Haier AL48LP2VHA Инструкция по монтажу
- Haier AW24LP2VHA Спецификация
- Haier AW24LP2VHA Инструкция по монтажу
- Haier AW36LP2VHA Спецификация
- Haier AW36LP2VHA Инструкция по монтажу
- Haier 1U24LP2VHA Спецификация
- Haier 1U24LP2VHA Инструкция по монтажу
- Haier 1U36LP2VHA Спецификация
- Haier 1U36LP2VHA Инструкция по монтажу
MRV S Key Features MRV S Lineup Outdoor Capacity Indoor Panel MVAWOO7MV2AA 9K MVAWOO9MV2AA 12K 18K MVAWO12MV2AA Wall Mount 24K MVAWO24MV2AA 30K MVAWO3OMV2AA 9K MVABOO9MV2AA 12K MVABO12MV2AA Compact Cassette 18K 9K MRV S 36 48 56 MVHP036MV2AA MVHP048MV2AA MVHP056MV2AA High Efficiency Highly efficient full DC inverter compressor and fan motor 21 serrated edge fan blade allows higher air movement at a lower sound level Large coil and 2 stage sub cooling circuit increase performance when the demand is high Air cooled electrical box helps increase reliability MVAWO18MV2AA MVABO18MV2AA MVALOO9MV2AA 12K MVALO12MV2AA 18K MVALO18MV2AA 24K MVALO24MV2AA 3OK MVALO3OMV2AA 36K MVALO36MV2AA 42K MVAL042MV2AA 48K MVAL048MV2AA 7K MVADOO7MV2AA 9K MVADOO9MV2AA Easy to Install Built in handles and designed skid for handling and rigging ease Two pipe refrigerant lines save time and resources Multiple piping connections simplify any jobsite condition Optional branch connector kits allow using FlexFit indoor units for application flexibility 12K MVADO18MV2AA Optimized Comfort 24K MVADO24MV2AA 24K AM24LP2VHA 36K PAD0890RA Return air grille PAD0890SA Supply air grille MVADO12MV2AA Slim Duct 18K PID pressure sensor enables more precise temperature control Non reversing 4 way valve avoids temperature fluctuation and component stresses Night time mode for quiet operation PB 95OKB PB 950MB Intelligent Eye High Static Duct High Static Duct requires branch box MS1 036Aor MS3 O36A to connect AM36LP2VHA PAD1210RA Return air grille PAD1210SA Supply air grille