Haier 1U26JABFRA [3/28] Warning
![Haier 1U26JABFRA [3/28] Warning](/views2/1812733/page3/bg3.png)
WARNING:
Use a cable of suitable length,Do not use tapped wires or an extension lead as this may cause
overheating, electric shocks, fire or explosion.
All the cables shall have got the local authentication certificate. During installation, when the
connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.
If refrigerant gas leaks during installation, ventilate the area immediately.oxic gas may be produced
After completing installation, check for refrigerant gas leakage
When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure
it is free of air, and use only the specified refrigerant (R32).
Make sure ground connection is correct and reliable.Do not earth the unit to a utility pipe, lightning
conductor or telephone earth lead. Imperfect earthing may result in electric shocks.
Be sure to install an earth leakage circuit explosion-proof breaker.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by
the manufacturer.
The breaker of the air conditioner should be all-pole switch and explosion-proof. The distance
between its two contacts should not be no less than 3mm. Such means for disconnection must be
incorporated in the wiring.
Read the precautions in this manual
carefully before operating the unit.
This appliance is filled with R32.
Ask your dealer or qualified personnel to carry out installation work.Do not attempt to install
the air conditioner yourself. Improper Installation may result in water leakage, electric shocks,
fire or explosion.
Keep this manual where the user can easily find it.
Install the air conditioner in accordance with the instructions in this installation manual
Be sure to use only the specified accessories and parts for installation work.
Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
Electrical work must be performed in accordance with relevant local and national regulations
and with instructions in this installation manual,Be sure to use a dedicated power supply circuit
only. The wiring method should be in line with the local wiring standard.The type of connecting
wire is H07RN-F.
.
The appliance must be stored in a room without continuously operating ignition sources, the radius of
the storage area should be no less than 2.5 m (for example:open flames, an operating gas appliance
or an operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Comply with national gas regulations.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
Cleaning and user maintenance shall not be made by children.
if the refrigerant comes into contact with fire,and explosion may be happen.
The appliance must be installed, operated and stored in a room with a floor area larger than 3m
The room should be well ventilated.
1
The air conditioner can not be discarded or scrapped randomly. If neccessary, please contact customer
service.
Connectors can not be reused in a confined space.
Содержание
- Room air conditioner installation manual 1
- Contents 2
- Keep this manual where the user can easily find it 3
- Read the precautions in this manual carefully before operating the unit this appliance is filled with r32 3
- Warning 3
- Cautio 4
- How to use dred appliance 4
- Important information rega rding the refrigerant used 4
- The maximum refrigerant charge amount m 5
- Maintenance items 11
- Adhesive tape 14
- Air inlet 14
- Air outlet 14
- Compressor inside of unit 14
- Drain hose 14
- Heating insulating material 14
- Indoor outdoor unit installation drawings 14
- Non adhesive tape 14
- Optional parts for piping 14
- Piping hole cover 14
- Please be subjected to the actual product purchased 14
- Saddle l s with screws connecting electric cable for indoor and outdoor drain hose 14
- The marks from to in the gure are the parts numbers the indoor unit should be installed at the recommended height 2m 14
- When installing the unit to wall roof or rooftop fix a supporter surely with nails or wires in preparation of earthquake and strong wind 2 air conditioner mounted not above and one meter away from electric equipment such as television 14
- Hfc 410a 21
- Cushion rubber 22
- Installation dimension unit mm 22
- Caution 23
- Connection of pipes 23
- Ceramic type of ac 250v t25a 26
- U53raafra 26
- Outdoor unit 27
- Australia 1300 729 948 haier com au new zealand 0800 424 372 haier co nz 28
- For haier appliances 28
Похожие устройства
- Haier 1U35JABFRA Инструкция по монтажу
- Haier 1U53RAAFRA Инструкция по монтажу
- Haier ABH090K5ERG Руководство по монтажу
- Haier ABH090K5ERG Инструкция по эксплуатации
- Haier ABH090K5ERG Инструкция по монтажу
- Haier ABH090K5ERG Брошюра
- Haier ABH105K5ERG Руководство по монтажу
- Haier ABH105K5ERG Инструкция по эксплуатации
- Haier ABH105K5ERG Инструкция по монтажу
- Haier ABH105K5ERG Брошюра
- Haier ABH125K5ERG Руководство по монтажу
- Haier ABH125K5ERG Инструкция по эксплуатации
- Haier ABH125K5ERG Инструкция по монтажу
- Haier ABH125K5ERG Брошюра
- Haier ABH140K5ERG Руководство по монтажу
- Haier ABH140K5ERG Инструкция по эксплуатации
- Haier ABH140K5ERG Инструкция по монтажу
- Haier ABH140K5ERG Брошюра
- Haier ABH071H5ERG Инструкция по монтажу
- Haier ABH071H5ERG Руководство по монтажу