Haier AS09NS3HRA [3/13] Warning
![Haier AS09NS3HRA [3/13] Warning](/views2/1812978/page3/bg3.png)
WARNING:
·
If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or
similarly qualified persons in order to avoid a hazard.
·
This appliance can be used by children aged 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have
been given superivision or instruction concering use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and
·
The wiring method should be in line with the local wiring standard.
user maintenance shall not be made by children without supervision.
·
The type of connecting wire is H07RN-F.
All the cables shall have got the European authentication certificate. During installation, when the
·
connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.
The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts
should not be no less than 3mm. Such means for disconnection must be incorporated in the wiring.
·
·
Make sure installation is done according to local wiring regulation by professional persons.
·
·
A leakage breaker must be installed.
Make sure ground connection is correct and reliable.
Cautions
3. If the fuse of indoor unit on PC board is
it with the type of
T. 3.15A/ 250V
outdoor
broken,change it with the type of
T.25A/250V
The refrigerating circuit is leak-proof.
1.Applicable ambient temperature range:
Specifications
The machine is adaptive in following
situation
The power plug and connecting cable
acquired the local
2. If the power supply cord is damaged, it
must be replaced
manufacturer
qualified
person.
4. The wiring method should be in line with
the local wiring
5. After installation, the power plug should
be easily reached.
6.The waste battery should be disposed
properly.
7. Please employ the proper power plug,
cord.
9.In order to protect the units,please turn
10.Please check the installation instruction of WiFi in the WiFi module
30 seconds
later, cutting off the power.
8.
Cooling
Indoor
Maximum:D.B/W.B
Maximum:D.B/W.B
D.B
Maximum:D.B
D.B
Minimum:D.B/W.B
Maximum:D.B/W.B
Minimum:D.B/W.B
Outdoor
Indoor
Outdoor
Heating
32
o
C/23
o
C
24
o
C/18
o
C
o
C/-8
o
C
43
o
C/26
o
C
-10
o
C
27
o
C
21
o
C/15
o
C
Outdoor
Maximum:D.B/W.B
Minimum:D.B
24
o
C/18
o
C
-15
o
C
(INVERTER)
o
C
7
-
Minimum:
Minimum:
or its service agent or a similar
broken,please
. If the fuse of
standard.
which fit into the
must have
off the A/C first,
by the
change
unit is
p
ower supply
attestation.
and at least
15
Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and
swing louver.
This appliance is not intended for use by persons (including children)
with reduced physiced, sensory or mental capabilities or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of appliance by person responsible for
their safety. Children should be supervised to ensure that they do not
play with the appliance.
grille of the air
or any other things into the
1
Содержание
- Keep this operation manual for future reference 1
- Lease read this operation manual before using the air conditioner 1
- Split type room air conditioner operation manual and indoor installation manual 1
- A leakage breaker must be installed make sure ground connection is correct and reliable 3
- Cautions 3
- Connecting cables break off it must be assured that the grouding wire is the last one to be broken off the breaker of the air conditioner should be all pole switch and the distance between its two contacts should not be no less than 3mm such means for disconnection must be incorporated in the wiring 3
- If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 3
- Make sure installation is done according to local wiring regulation by professional persons 3
- The type of connecting wire is h07rn f all the cables shall have got the european authentication certificate during installation when the 3
- The wiring method should be in line with the local wiring standard user maintenance shall not be made by children without supervision 3
- This appliance can be used by children aged 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given superivision or instruction concering use of the appliance in a safe way and understand the hazards involved children shall not play with the appliance cleaning and 3
- Warning 3
- Caution 4
- Cautions 4
- Check proper installation of the drainage securely 4
- Please call sales service shop for the installation do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage 4
- Warning 4
- Accordance 5
- Before asking for service check the following first 5
- Conformity for the models 5
- Gwp global warming potential 5
- Important information rega rding the refrigerant used 5
- Trouble shooting 5
- Air purifying filter inlet 6
- Ambient temp display 6
- Anion generator 6
- Display board 6
- Emergency switch 6
- Extra function button 6
- Function 6
- Horizontal flap 6
- Indoor unit 6
- Inlet grille 6
- Inside 6
- Operation mode indicator 6
- Outdoor unit 6
- Outlet 6
- Parts and functions 6
- Power indicator 6
- Remote controller 6
- Remote signal receiver 6
- Timer mode indicator 6
- Vertical blade 6
- Air flow direction adjustment 7
- Base operation 7
- Cautions 7
- Emergency operation and test operation 7
- It is advisable not to keep horizontal flap at downward position for a long time in coolor dry otherwise condensate water might occur 7
- Operation 7
- When adjusting the flap by hand turn off the unit when humidity is high condensate water might occur 7
- Comfortable sleep 8
- Controller 8
- For a minute and then start adjusting by remote 8
- Healthy airflow operation 8
- In cool dry mode 8
- Modes are set up at the same time 8
- Operation 8
- Operation mode 8
- Setting the comfort work conditions 8
- According to the time setting sequence of timer on or 9
- After replacing batteries or a power failure happens time 9
- After unit starts select your desired operation mode 9
- Operation 9
- Press button 0 will appear after 10 seconds the time display will be blank 9
- Press button to change timer mode 9
- Press button to set time 9
- Setting should be reset 9
- Then select your desired timer mode timer on or 9
- Timer off either start stop or stop start can be achieved 9
- Timer off or will flash 9
- Timer on off on off operation 9
- Accessory parts 10
- Drawing for the installation of indoor units 10
- Indoor unit installation 10
- More than 10cm 10
- More than 15cm 10
- Necessary tools for installation power source 10
- Selection of installation place 10
- Selection of pipe 10
- Connecting the indoor outdoor electric cable 11
- Fixing the indoor unit body 11
- Indoor unit installation 11
- Left left rear piping 11
- Other direction piping 11
- Rear piping 11
- Removal of indoor unit body 11
- Removing the wiring cover 11
- Check for installation and test run 12
- Check items for test run 12
- Cutting and flaring work of piping 12
- On drainage 12
- Please kindly explain to our customers how to operate through the instruction manual 12
- Power source installation 12
- When connecting the cable after installing the indoor unit 12
- When connecting the cable before installing the indoor unit 12
- And the white side face the unit 13
- Attach air purifying filter 13
- Attach the filter 13
- Attach the standard air filter 13
- Clean the filter 13
- Close doors and windows during operation 13
- Close the grille surely 13
- Close the inlet grille 13
- Detach old air purifying filter 13
- Do not block the air inlet or outlet 13
- For smart use of the air conditioner 13
- If the unit is not to be used for a long time turn off the power supply main switch 13
- Maintenance 13
- Necessary installation 13
- Note air purifying filter is optional part 13
- Open the inlet grille by pulling it upward 13
- Please keep the bacteria killing medium air purifying filter in avoid long time directly sunshine when you stop using it or its ability of sterilization will be reduced 13
- Prop up the inlet grille by using a small device named grille support 13
- Purifying filter face outside 13
- Remove the filter 13
- Replacement of air purifying filter 13
- Setting of proper room temperature 13
- Slide the knob slightly upward to release the filter then withdraw it 13
- The bacteria killing medium air purifying filter will be used for a long time no need for replacement but in the period of using them you should remove the dust frequently by 13
- The cool and dry conditions 13
- The photocatalyst air purifying filter will be solarized in fixed time in normal family it will be solarized every 6 months 13
- Use the louvers effectively 13
- Use the timer effectively 13
- Using vacuum cleaner or flaping them lightly otherwise its performance will be affected 13
- Which located in the right side of the indoor unit 13
Похожие устройства
- Haier AS09NS3HRA Брошюра
- Haier AS12NS3HRA Инструкция по монтажу
- Haier AS12NS3HRA Инструкция по эксплуатации
- Haier AS12NS3HRA Руководство по эксплуатации
- Haier AS12NS3HRA Брошюра
- Haier AS15NS3HRA Инструкция по монтажу
- Haier AS15NS3HRA Инструкция по эксплуатации
- Haier AS15NS3HRA Руководство по эксплуатации
- Haier AS15NS3HRA Брошюра
- Haier AS18NS3HRA Инструкция по монтажу
- Haier AS18NS3HRA Инструкция по эксплуатации
- Haier AS18NS3HRA Руководство по эксплуатации
- Haier AS18NS3HRA Брошюра
- Haier AS24NS3HRA Инструкция по монтажу
- Haier AS24NS3HRA Инструкция по эксплуатации
- Haier AS24NS3HRA Руководство по эксплуатации
- Haier AS24NS3HRA Брошюра
- Haier AS07BS4HRA Инструкция по монтажу
- Haier AS07BS4HRA Инструкция по эксплуатации
- Haier AS07BS4HRA Руководство по эксплуатации