LG A12AHM [26/31] Auto restart
![LG A12AHM [26/31] Auto restart](/views2/1081438/page26/bg1a.png)
26 Room Air Conditioner
Operating Instructions
Power button
High
Speed
Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Forced operation
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
Heat pump Model
Cooling Model
Room Temp. ≥ 24°C21°C ≤ Room Temp. < 24°C Room Temp. < 21°C
Operating mode Cooling Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High High
Setting Temperature
22°C22°C23°C24°C
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the value
when the fan speed is set to high, and the capacity will be lower
at low or medium fan speed.
High fan speed is recommended when you wish to cool the room
quickly.
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1
"beep".
If you want to stop the operation, re-press the button.
Auto restart function has set enable as factory default.
But customer can set up by following this instruction.
To be disable function
- Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1)
blinks 4 times.
To be enable function
- Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1)
brights 4 times.
NOTICE
Содержание
- Air conditioner 1
- Lg room 1
- Owner s manual 1
- Electrical safety 1 2
- For your records 2
- Introduction 0 2
- Maintenance and service 7 2
- Operating instructions 3 2
- Precaution 2
- Prior to operation 2
- Read this manual 2
- Room air conditioner owner s manual 2
- Safety precautions 2
- Table of contents 2
- Be sure not to do 3
- Be sure to follow the instruction 3
- English 3
- I installation 3
- Safety precautions 3
- I operation 4
- English 5
- I installation 6
- English 7
- I operation 7
- I disuse 8
- Cleaning and maintenance 9
- English 9
- Owner s manual 9 9
- Preparing for operation 9
- Prior to operation 9
- Safety precautions 9
- Service 9
- Features 10
- Indoor 10
- Introduction 10
- Outdoor 10
- Symbols used in this manual 10
- This symbol alerts you to hazards that may cause harm to the air conditioner 10
- This symbol alerts you to the risk of electric shock 10
- This symbol indicates special notes 10
- Electrical safety 11
- English 11
- Adapter plug 12
- Electrical safety 12
- Metal screw 12
- Receptacle cover 12
- Room air conditioner 12
- Temporary method 12
- Temporary use of an adapter 12
- Temporary use of an extension cord 12
- Warning never use the appliance with a broken adapter 12
- English 13
- How to insert the batteries 13
- Operating instructions 13
- Operation indicating lamps 13
- Owner s manual 13 13
- Signal receptor 13
- Storage and tips for using the remote controller 13
- Controls 14
- Operating instructions 14
- Operation mode 14
- Remote control operations 14
- Room air conditioner 14
- Cooling operation 15
- English 15
- Operating instructions 15
- Owner s manual 15 15
- Auto operation cooling model only 16
- Operating instructions 16
- Room air conditioner 16
- Auto changeover operation heat pump model only 17
- English 17
- Operating instructions 17
- Owner s manual 17 17
- Healthy dehumidification operation 18
- Operating instructions 18
- Room air conditioner 18
- English 19
- Heating operation heat pump model only 19
- Operating instructions 19
- Owner s manual 19 19
- Jet cool operation 20
- Operating instructions 20
- Room air conditioner 20
- English 21
- Jet heat operation optional 21
- Neo plasma air purifying operation only 22
- Neo plasma purification operation optional 22
- Operating instructions 22
- Room air conditioner 22
- English 23
- For more details refer to functions next pages 23
- Nd f operation 23
- Additional features 24
- Check the indicator for a m and p m 24
- Delay start pre set stop 24
- Operating instructions 24
- Room air conditioner 24
- Select one of the following four types of operation 24
- Setting the time 24
- Sleep mode 24
- The sleep mode will be operated at slow fan speed cooling or medium fan speed heat pump only for a comfortable sleep 24
- Air circulation mode 25
- Airflow direction control 25
- Auto clean 25
- Chaos air economizes power consumption and prevents overcooling the fan speed is automatically changed from high to low or vice versa depending on the ambient temperature 25
- English 25
- Operating instructions 25
- Owner s manual 25 25
- Auto restart 26
- Forced operation 26
- Helpful information 26
- High speed 26
- Notice 26
- Operating instructions 26
- Room air conditioner 26
- Test operation 26
- Air filter 27
- English 27
- Indoor unit 27
- Maintenance and service 27
- Outdoor unit 27
- Warning turn the system off before cleaning to clean wipe with a soft dry cloth do not use bleach or abrasives 27
- Cleaning filter 28
- Insert the plasma filter after perfectly drying it in shade now insert air filter and close the front panel completely by matching the hook 28
- Lift the front panel hold it up and pull the air filter 28
- Maintenance and service 28
- Put the plasma filter into the neutral detergent for 1 2 hours and then raise it 28
- Recomended use period about 3 months 28
- Remove the plasma filter 28
- Room air conditioner 28
- Warning don t touch the plasma filter within 10 seconds after opening the inlet grille it may cause electric shock 28
- Before calling for service 29
- Common problems and solutions 29
- English 29
- Air conditioner freezing up 30
- The air conditioner may be operating abnormally when 30
- Troubleshooting 30
Похожие устройства
- HP LaserJet Ent 500 M525f Инструкция по эксплуатации
- Hitachi C10FCE2 Инструкция по эксплуатации
- HP LaserJet Ent 500 M575f Инструкция по эксплуатации
- Hitachi C10FCH2 Инструкция по эксплуатации
- HP LaserJet Ent 500 M575dn Инструкция по эксплуатации
- Hitachi C10FSB Инструкция по эксплуатации
- LG A09LHU UPU6 Инструкция по эксплуатации
- HP LaserJet Ent 500 M525dn Инструкция по эксплуатации
- Hitachi C10FSH Инструкция по эксплуатации
- LG A09LHR Инструкция по эксплуатации
- HP LaserJet Pro 400 M425dw Инструкция по эксплуатации
- Hitachi C12LCH Инструкция по эксплуатации
- LG A09LHM Инструкция по эксплуатации
- HP LaserJet Pro M275nw Инструкция по эксплуатации
- Hitachi C12LSH Инструкция по эксплуатации
- LG A09LHH Инструкция по эксплуатации
- Canon Pixma MG2245 Инструкция по эксплуатации
- Hitachi C8FSE Инструкция по эксплуатации
- LG A09LHD Инструкция по эксплуатации
- Sony VGP-BMS11/B Black Инструкция по эксплуатации
Скачать
Случайные обсуждения