Haier AU42NAIMCA [7/33] Operation
![Haier AU42NAIMCA [7/33] Operation](/views2/1814756/page7/bg7.png)
Operation
5
Clock set
When unit is started for the first time
and after replacing batteries in remote
controller, clock should be adjusted as follows:
Press CLOCK button, "AM"or "PM" flashes.
Press or to set correct time. Each press will increase
or decrease 1min . If the button is kept depressed, time
will change quickly.
After time setting is confirmed, press SET, "AM" and "PM"
stop flashing, while clock starts working.
Remote contronller's operation
When in use, put the signal transmission head directly
to the receiver hole on the indoor unit
The distance between the signal transmission head and
the receiver hole should be within 7m without any
obsacles as well.
Don't throw the controller, prevent it from being damaged.
When electronic-started type fluorescent lamp or change-over
type fluorescent lamp or wireless telephone is installed in the
room, the receiver is apt to be disturbed in receiving the signal
so the distance to the indoor unit should be shorter.
Loading of the battery
Slinghtly press " " and push down the cover.
Load the batteries as illustrated.
2 R-03 dry batteries, (cylinder)
Be sure that the loading is in line with the "+"/"-" pole
request as illustrated.
Put on the cover again
Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 5 mins.
reset key
AM
TEMP
SWING
FAN
ON
OFF
MODE SLEEP
SET
CLOCK
TIMER
RESETLOCK
AM
TIMER
CLOCK
SET
TIME
TIME
SLEEP
TEMP
TEMP
SWING
MODE
FAN SPEED
ON
OFF
:
1
3
2
THE MACHINE IS ADAPTIVE IN FOLLOWING SITUATION
Applicable ambient temperature range:
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum: D.B/W.B
Minimum: D.B/W.B
Maximum: D.B/W.B
Minimum: D.B
Maximum: D.B
Minimum: D.B
Maximum: D.B/W.B
Minimum: D.B/W.B
32 C/23 C
18 C/14 C
18 C
43 C/26 C
27 C
15 C
24 C/18 C
-7 C/-8 C
Note:The waster batteries should be disposed properly,use two new same-type batteries when loading.
If the remote controller canít function normally or doesnít work at all,use a sharp-pointed item to pres
the reset key.
Hint:Remove the batteries in case unit wonít be in usaged for a long period.
If there are any displays after taking-out just need to press reset key.
Содержание
- Ap42nacaaa au42naiaaa hpu 44h03 ap42nacmaa au42naimca hpu 42c03 1
- Fan speed 1
- No 010571223 1
- On off 1
- Operation manual 1
- Packaged unit 1
- Content 2
- Operation 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Cautions 4
- Air filter 5
- Air outlet 5
- At side and rear 5
- Indoor unit 5
- Inlet grill 5
- Operation panel 5
- Outdoor unit 5
- Outlet grill 5
- Remote controller 5
- Manual operation 6
- Note auxiliary heat function is not available for cooling only type heating function is not available 6
- Remote controlled operation 6
- Clock set 7
- Loading of the battery 7
- Operation 7
- Put on the cover again confirmation indicator 7
- Remote contronller s operation 7
- The machine is adaptive in following situation 7
- Manual operation 8
- Operation 8
- Remote controlled operation 8
- Cooling 9
- Manual operation 9
- Operation 9
- Remote controlled operation 9
- Manual operation 10
- Operation 10
- Remote controlled operation 10
- Heating 11
- Manual operation 11
- Note for cooling only type this function is invalid 11
- Operation 11
- Remote controlled operation 11
- Manual operation 12
- Operation 12
- Remote controlled operation 12
- In automatic running the conditioner will run under automatically selected working mode of sleeping 4 in fan running the sleep function is invalid 13
- In heating the single cooling conditioners do not have the function 13
- Operation 13
- Remote controlled operation before sleeping you can press the sleep button the conditioner will run under comfort sleep mode and give you a comfort sleep usage of the sleep function after starting set the run mode and press the sleep button run mode 1 in cooling and dry 13
- Manual operation 14
- Operation 14
- Remote controlled operation 14
- Timer on off 14
- Timer on off operation 14
- Timer operation 14
- To cancel timer mode 14
- Manual operation 15
- Operation 15
- Remote controlled operation 15
- Timer on off 15
- Timer on off function 15
- To cancel timer mode 15
- Air flow adjustment 16
- Operation 16
- Cold draft prevention 17
- Defrosting 17
- Fan speed changes 17
- Min delay protection 17
- Operation hints 17
- Unit operation 17
- Use objectively 17
- Energy saving 18
- On off 18
- Cautions for the operation 19
- Air filter cleaning 20
- Indoor and outdoor cleaning 20
- Maintenance 20
- After season maintenance 21
- Before season maintenance 21
- Maintenance 21
- Followings are not problems 22
- Trouble shooting 22
- Air conditioner won t start 23
- Before ask for services please first check your unit against following 23
- Poor cooling 23
- Poor cooling or heating 23
- When problems occur 23
- Indoor outdoor unit connection 24
- Over 100cm 24
- Over 10cm 24
- Over 60cm 24
- Indoor outdoor unit connection 25
- Over 100cm 25
- Over 10cm 25
- Over 60cm 25
- Parts in the following list are accessories for the unit installation which can be used if necessary 26
- Standard accessories 26
- Tools necessary 26
- Delivery facing up 27
- Display of whole unit 27
- Installation of outdoor unit 27
- Installation procedures 27
- Installation of indoor unit 28
- Installation procedures 28
- Installation of fall prevention fitting metal 29
- Installation of l shaped metal 29
- Installation procedures 29
- Piping connection 29
- Installation procedures 30
- Installation procedures 31
- Electric wiring 32
- Installation procedures 32
- Others 33
Похожие устройства
- Haier HSU-07HV03/R2(DB) Инструкция по эксплуатации
- Haier HSU-09HV03/R2(DB) Инструкция по эксплуатации
- Haier HSU-09HV03/R2(SDB) Инструкция по эксплуатации
- Haier HSU-12HV03/R2(DB) Инструкция по эксплуатации
- Haier HSU-12HV03/R2(SDB) Инструкция по эксплуатации
- Haier HSU-18HV03/R2(DB) Инструкция по эксплуатации
- Haier HW-07LN03 Инструкция по эксплуатации
- Haier HW-07LN03 Сервис мануал
- Haier HW-09LN03 Инструкция по эксплуатации
- Haier HW-09LN03 Сервис мануал
- Haier HW-12LN03 Инструкция по эксплуатации
- Haier AB212BCBAA Инструкция по эксплуатации
- Haier HSU-12CR03-Y Инструкция по монтажу
- Haier HSU-12CR03-Y Инструкция по эксплуатации
- Haier HSU-18CR03-Y Инструкция по монтажу
- Haier HSU-18CR03-Y Инструкция по эксплуатации
- Haier HWR06XCJ Инструкция по эксплуатации
- Haier HFU-09HA03(B)/R1 Инструкция по эксплуатации
- Haier HFU-12HA03(B)/R1 Инструкция по эксплуатации
- Haier HFU-09H03/R2(DB) Инструкция по эксплуатации